Mettler SM1520 Precision Balance

LabMakelaar Benelux B.V.
item image

Description by the supplier

Weighing range: 15 kg


Readability: 0.1 g


Weighing platform: 320 x 230 mm


Balance features a “raised” display for easy addition during weighing.


Provided with a calibration mark

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag Flat polygonal sheets, Set (1 mg - 500 mg), Plastic Box-cover
Radwag Flat polygonal sheets, Set (1 mg - 500 mg), Plastic Box

Flat polygonal sheets - set (1 mg - 500 mg) F1 class mass standards are exceptional measuring tools  (more)that represent the pinnacle of precision in the field of metrology. Classified as F1 metrology class, they are perfect for advanced applications where every detail of measurement is of paramount importance. F1 Class Mass Standards – Key Features Highest Precision and Accuracy - F1 class mass standards are characterized by absolute measurement precision and extraordinary accuracy. They are designed to meet the most stringent standards for acceptable deviation from actual weight. Stability under Difficult Conditions - An important feature of F1 class mass standards is their ability to maintain measurement stability even under harsh environmental conditions. The standards of this class are resistant to changes in temperature, humidity and other factors that affect the precision of measurements. Calibration in Accordance with International Standards - The calibration process for F1-class mass standards is rigorous and in accordance with international standards. This ensures that standards of this class are globally recognized and can be used in different countries. Specialized Construction Materials - F1-class standards are often made of materials with unique physical properties. This provides them not only with precision, but also with durability and wear resistance. The set includes: plastic box 12 mass standards 1 pair of tweezers 1 brush Material: nickel silver *The 1 mg, 2 mg and 5 mg mass standards are made of aluminum. Application 1. Industrial Metrology F1 class mass standards are used in metrology laboratories engaged in the testing and maintenance of measurement standards. 2. Scientific Research In scientific research, especially in high-precision fields such as physics and astronomy, F1-class mass standards are a key tool. 3. Aerospace Industry In the precision mass measurements required by the aerospace industry, F1-class standards guarantee reliability and accuracy. 4. Calibration Laboratories In calibration laboratories where uniformity and precision are a priority, F1-class mass standards are the standard of excellence. F1-class mass standards are synonymous with the highest quality and precision in the field of metrology. Their use is crucial where even the slightest deviation from the standard can carry unpleasant consequences. They are tools for advanced applications that contribute to raising standards in the field of mass measurement.

€344.00 ex VAT
Poland
mass standards
Radwag WLC 1/A2/C/2/IO Precision Balance-cover
Radwag WLC 1/A2/C/2/IO Precision Balance

Precision of WLC balances Fast, accurate and repeatable weight determination. Energy-efficient elect (more)ronics and display, combined with an internal rechargeable battery, are the perfect duo to allow you to work without access to mains power. Precision not just in the name When we designed this balance, we took care of the smallest details – both those you can’t see, hidden in the solid housing, and those you can touch. This balance is the result of a combination of our experience and true precision. The power of steel The use of stainless steel for the pan guarantees you a long life for the balance. It is not afraid of contact with moist objects or accidental splashes. It has been with us for years, and will stay for a long time to come The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient. Internal power The internal rechargeable battery combined with the energy-saving display and electronics allow many hours of operation without mains power. Time counts The balance is equipped with a real-time clock that provides accurate time measurement in a way that is independent of external power supply. There is potential Printer, computer, flash drive or additional display – you can easily connect them thanks to the fact that the balance is equipped with interfaces: 2 x RS232, USB type A and USB type B. Optionally, the balance can be equipped with 4 IN and 4 OUT. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. Good ALIBI The ALIBI memory used in the terminal allows for safe storage of weighing records without the possibility of unauthorized interference. A single measurement remains in the ALIBI memory up to a preset limit number of days of storage, counting from the date it was taken. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€522.00 ex VAT
Poland
balances, precision balances
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y-cover
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y

XA17 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 17 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

Poland
microbalances accessories, pipettes, ultra microbalances, ultra & microbalances accessories, scales, pipettes calibration, analytical balances, analytical balances accessories, balances, balances accessories, microbalances
Radwag MA 110.X2.IC.A.WH Moisture Analyzer-cover
Radwag MA 110.X2.IC.A.WH Moisture Analyzer

MA X2.IC.A moisture analyzers are hi-tech measuring instruments intended for quick determination of  (more)relative moisture content, dry mass content and other parameters in samples of different substances. MA.X2.IC.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X2.IC.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X2 Series moisture analyzers: Automatic opening and closing of the drying chamber 5” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X2.IC.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€1,998.00 ex VAT
Poland
moisture analysers, balances
People are watching right now:
Edwards nXDS10iR Dry Scroll Pump-cover
Edwards nXDS10iR Dry Scroll Pump

Edwards nXDS10iR Dry Scroll PumpFeatures - Bearing shield ensures separation between process gases a (more)nd bearing lubrication to ensure clean vacuum and no possibility of contamination. - Smart motor drive means consistent performance globally, pump overload protection and remote start/stop capability. - High flow gas ballast feature allows pumping of vapours including water vapour at up to 240 gh-1 - Simple single sided scroll design allows maintenance to be done in minutes for low cost of ownership and maximum up-time. - Enhanced versions offer up to 20% lower peak power requirements during initial pump down. The nXDS allows a wide range of control and communication options The nXDS comes as standard with a manual, easy to use, gas ballast port A perfect companion for your turbomolecular pump With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features Edwards nXDS is the best performing pump in its class.nXDS improves on legacy XDS pumps by offering increased pumping speeds, combined with lower ultimate pressures, lower power consumption and lower noise - up to 20 times quieter than other pumps. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. nXDS pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimised pumping performance globally. Unlike the standard nXDS10i, the Edwards nXDS10iR isdesigned for specialist applications such as gas recirculation, rare gaspumping and recovery or other applications where the dilution of the pumped gasis undesirable, or where sealing is integral to minimizing potential gas loss. Click Here to View Product Video INCLUDED: The Edwards nXDS10iR Dry Scroll Pump includes: - 1 Year Full Parts and Labor Warranty - Power Cord - Manufacturer's Documentation - Operator's Manual Edwards nXDS10iR Dry Scroll Pump Technical Specifications Nominal rotational speed1800 rpmDisplacement12.7 m3h-1 / 7.5 ft3min-1Peak pumping speed11.4 m3h-1 / 6.7 ft3min-1Ultimate vacuum (total pressure)0.007 mbar / 0.005 TorrMinimum standby rotational speed1200 rpmSpeed control resolution (percentage of full rotation speed)1%Pumping speed at minimum rotational speed7.5Maximum continuous inlet pressure200 mbarMotor power 1-ph280 WPower connector 1-phIEC EN60320 C13Recommended fuse10A, 250Vac rmsWeight25.8 kg / 57 lbInlet flangeNW25Exhaust flangeNW25Noise level52 dB(A)Vibration at inlet flange< 4.5 mms-1 (rms)Leak tightness (static)< 1x10-6 mbar ls-1Operating temperature range10 to 40 °C / 41 to 104 °FElectrical Supply115/230VComparison of ModelsSpecificationEdwards nXDS6iREdwards nXDS10iREdwards nXDS15iREdwards nXDS20iRNominal rotational speed (rpm)1800180018001800Displacement (m³h⁻¹ / ft³min⁻¹)6.2 / 3.612.7 / 7.517.1 / 10.128.0 / 16.5Peak pumping speed (m³h⁻¹ / ft³min⁻¹)6.2 / 3.611.4 / 6.715.1 / 8.922.0 / 13.0Ultimate vacuum (total pressure) (mbar / Torr)0.020 / 0.0150.007 / 0.0050.007 / 0.0050.030 / 0.022Weight (kg / lb)26.2 / 5825.8 / 5725.2 / 5625.6 / 56Inlet flangeNW25NW25NW25NW25Noise level (dB(A))52525252Operating temperature range (°C / °F)10 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 104Electrical Supply115/230V115/230V115/230V115/230V.comparison-table tr td:nth-child(3) { background-color: #fffacd; }

$6,995.00 ex VAT
United States
pumps liquid & other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]