Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
Galileo Equipos
Location
PI El Nogal - Spain
Price
€44,123.01 
(ex. VAT)
This item is
for sale
State of item
new
Categories

CyFlow Cube 6

Galileo Equipos€44,123.01 (ex VAT)
item image

Description by the supplier

The flow cytometer CyFlow Cube 6, fully self-contained and ultra-compact, has been designed for all applications in cell analysis and absolute count with the best ratio quality-performance/price. CyFlow Cube 6 provides a flow cytometry accurate with up to 6 optical parameters. Equipped with a blue and a red laser optional, and 4 fluorescence channels (FL1-FL4) more Forward Scatter (FSC) and Side Scatter (SCC) constitute an optical system, powerful and affordable flow cytometry. PC and software CyView integrated. Optional: automatic Charger optional CyFlow Robby for well plates and tubes.


It shows the price for the model CY-S-3060R_V2 - CyFlow® Cube 6 Microbiology - (1 laser 488 nm; 5 parameters). For other configurations, consult drop-down.


Features


Light sources

Up to 2 light sources simultaneous: blue laser 50 mw @ 488; red laser 25mW @ 638nm Optical

Optical system, modular PMT of the selected preamplifier built-in for FSC, SSC, FL1-FL4

Optical filters interchangeable

Flow system

Bucket of flow of quartz for transport of samples laminar and approach to hydrodynamic processes.

Count absolute volumetric true (TVAC) based on the measurement of volume mechanical

Syringe pump accuracy computer-controlled, speed continuously adjustable from 0-20 ál / sec.

Software

CyView, software FCM based on Windows ™ for the acquisition of real-time data, analysis of data in real-time and viewing data in real-time

Easy configuration of templates experimental (configuration files)

Data format Standard for flow cytometry (FCS) for storage of original data and evaluated

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

This GE IN Cell Analyser 1000 Optigrid Structured Light Imaging System was removed from a university (more) lab where it was surplus to requirements. The microscope focus motor/Z-Drive has been removed from this unit. We have removed the microscope focus motor/Z-Drive from this system. It is sold for spares/repairs. Included in the system are; 1x GE IN Cell Analyzer 1000: Dims: L85cm W70cm H70cmThe unit is in good cosmetic condition. When connected up to the power supply we could not hear the unit power on.Inside the unit it appears have been tampered with as there are several cables and connector cables not attached to anything the EARTH cable is also not attached. A circuit board has been removed from the unit. this may explain why we could not get the unit powered up. 1x GE IN Cell Analyser 1000 Kinetic OZ EnabledModel No. 28-4051-29System No. 1316043The unit powers on and is in good cosmetic condition.The fans are working, they can be heard powering up immediately once the unit is powered on. 1x GE IN Cell Analyser 1000 ENDPNT OZ EnabledModel No. 28-4051-28System No. 1358008The unit powers on and is in good cosmetic condition. The unit appears to have been stripped only 1x HP Workstation 6200 PC and 1x MVP Series power supply were still inside it. The Kinetic OZ Enabled unit appears to be complete with an Optigrid light imaging system. We have fitted the GE IN Cell Power supply back into the rack unit where it should be housed. EMKA Keys:Model 2233X2x keys for GE IN Cell Analyser 1000 ENDPNT OZ Enabled2x keys for the GE IN Cell Analyser Kinetic OZ EnabledAll 4 keys are in good cosmetic condition and open and lock both the Kinetic and the ENDPNT units. We did not connect up the GE IN Cell 1000 to the GE 1000 Kinetic OZ Enabled unit as one of the communication cable connections at the back of the rack has come away and will need to be fixed back on. Without this being fixed we do not believe the systems to be aware of each other. 1x Optigrid Light Imaging System:Model QIOPTIQThe unit powers on and is in good cosmetic condition. 1x Xenon ARC Lamp Power supply w 2x keys:Type 6Part No. 56409187The unit powers on and is in good cosmetic condition. The keys do not fit in the barrel well and do not turn. The LCD screen is working and reads clearly. Keys:model No. 901The units are in good cosmetic condition 2x MVP Series Power supplies. ( 1x in each rack unit)Model Nos. MP8-3Q-1L-00Both units power on and are in good cosmetic condition. There is dust around and on both units from general use. 1x Hamilton power supplyModel No. 231352/00The unit powered on and is in good cosmetic condition. 2x APC rack PDUThe units power on and are in good cosmetic condition. 1x GE cO2 Controller:Ser No. 1352436The unit powers on and is in good cosmetic condition. The LCD screen is working and reads clearly. All dials and switches appear responsive to the unit. 2x Hewlett Packard PC's: HP workstation xw6200:The units both power on and are in good cosmetic condition.There is some dust around the units from general use. Programs on PC:•Overlord 2Version 2.1.0.0 •IN Cell Analyser 1000 3.5•IN Cell Analyser 1000 3.6The program is password protected and we could not get past this window to access other parts of the program. 'Shutter Counter 1984048'. 3 x Low Voltage Computer Cables:•28-4060-63 Umbellcal Axis 0734•28-4060-66 0647•28-4060-68 Umbellcal Hamilton 0738 1x Xenon lamp Bulb:Model OSRAM XBO 100W OFRThe box had been opened. We cannot confirm if this lamp has been used. The unit was in good cosmetic condition.

£3,015.00 ex VAT
United Kingdom
flow cytometers
Accuris E7500 QuadCount Automated Cell Counter-cover
Accuris E7500 QuadCount Automated Cell Counter

Accuris QuadCount Automated Cell Counter The Accuris QuadCount™ improves on the simple technique of  (more)brightfield microscopy by utilizing an LED light source, precision optics and a high resolution CMOS detector. A finely tuned, motorized XYZ positioning stage provides for extra fine focusing and ability to capture multiple images.With count speeds at fast as 20 seconds per sample, the Accuris QuadCount provides many advantages over the tedious and time consuming manual hemocytometry method. The advanced software eliminates human bias in dead/live determinations, reduces counting errors, saves time, and improves efficiency.The QuadCount utilizes a unique 4-chambered disposable QuadSlide™. Four samples can be processed in one slide (twice the capacity of standard 2-chambered slides), decreasing consumable costs. Each chamber has a hydrophilic inner surface with an engraved grid pattern. High precision production and molding ensure that each QuadSlide meets the rigorous standards and dimensional tolerances required for optimal counting performance. 3 Count Modes Available to analyze different sample volumes. - Quick Mode: 0.15uL / 20 seconds (1 image frame) - Normal Mode: 0.9 uL / 30 seconds (6 image frames) - Precise Mode: 3.6 uL/ 100 seconds (24 image frames) The QuadCount’s ability to analyze larger sample volumes/multiple images provides significantly better accuracy.The Accuris QuadCount incorporates the highest quality optical and electronic components, such as a 4X objective lens and 5MP CMOS detector, to ensure reliable performance and consistent results. The precision motorized stage adjusts the position of the lens and sensor assembly in micron increments for automatic focus. Multiple image frames (up to 24) can be captured to increase the volume of sample counted, providing a higher level of accuracy.Correct focus is crucial for accurate counts of viable cells. The QuadCount’s proprietary autofocus system and image analysis software work in conjunction with the motorized stage to analyze and capture images in the proper focal plane.Advanced detection algorithms easily manage irregularly shaped and aggregated cells. Often misinterpreted by visual counting, correct analysis of these cells is performed by QuadCount’s software, resulting in more accurate counts. User to user variation is eliminated. Click Here to View Product Video INCLUDED: The Accuris QuadCount Automated Cell Counter includes: - USB Flash Drive - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$3,848.00 ex VAT
United States
cell counters, flow cytometers
People are watching right now:
4titude a4S Automatic Heat Sealer-cover
4titude a4S Automatic Heat Sealer

The 4titude a4S Automatic Heat Sealer requires no air supply, enabling the flexibility to be used on (more) standard lab benches as a stand-alone unit, or integrated within a robotic set up. The unit features a rapid heating element for quick start-up, and the stand-by function saves energy when the unit is not in use. The 4titude a4S Automatic Heat Sealer is compatible with a wide range of SBS footprint plates, including all PCR plate formats from 96 well to 1536 well, assay plates, deep well storage plates and microplates. Varying plate heights, from 3 mm to 60 mm can be accommodated with minimal adjustments of the instrument. Plates are presented in the portrait format and the plate position on the shuttle allows good access for robotic integration. Rolls with a width of between 75-85 mm can be loaded in either of two roll positions, depending on roll length and available space, enabling the 4titude a4S Automatic Heat Sealer to fit under the gantree of most liquid handling robots. The width and length of the applied seals are set to precisely cover an SBS footprint plate without interfering with plate stacking. The seal position can be adjusted to give an overhang at one end of the plate to facilitate ease of seal removal. Specifications: Sealing Temperature Range: 100 – 195°C Sealing Time Range: 0.1 – 10 Sec Connection: RS-232 Serial Port, USB Port Dimensions: 230 x 507 x 276 mm Weight: 27 kg

€3,500.00 ex VAT
Netherlands
laboratory modules, sealing
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]