Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

Optics / photonics equipment

CyFlow Space-cover
CyFlow Space

The flow cytometer CyFlow Space multi-laser of high range combines flexibility and accuracy. When y (more)ou select up to 5 sources of light different, 16 parameters of the analysis, a grading module is optional and the patented method of Counting Absolute Cell Volume (TVAC) for the counting of real cells and particles without the use of calipers, you can find the device configuration optimum for each application. The forwarder of optional high speed and the ability to analyze up to 25,000 particles per second make the CyFlow Space flow cytometer is ideal for the high demands. It shows the price of the configuration CY-S-3001_VA1 (1 laser 488/50-5P). Refer to available configurations in the table side and contact to budget. Features System configuration modular CyFlow Space: individual selection of up to 5 light sources and up to 16 parameters of analysis Flexible conversion and upgrade capability of the system. Sensitivity to fluorescence: ≤ 100 MESF (FITC) | ≤ 50 MESF (PE) Recognition of micro-particles ≥ 100 nm Count volumetric cells absolute (TVAC) CCD camera integrated to control the sample flow. Optional: charging Station automatic high-speed for microtiter plates 96-and 384-well Optional: module sorter CyFlow for classification of particles and cells is not destructive, closed Light sources Selection of up to 5 light sources different: - Blue laser: 50mW @ 488, 200mW @ 488 - Red laser: 25mW @ 638nm, 40mW @ 640nm - Violet laser: 100mW @ 405nm - UV laser: 60mW @ 375nm - Green laser: 30mW @ 532nm, 100mW @ 532nm - Laser-yellow: 100mW @ 561 nm - Laser orange: 50mW @ 594 - UV-LED 'high power': 365 nm Optical Optical system modular with photomultiplier tubes (PMT) for FSC, SSC, FL1-FL13 Optical filters replaceable Flow system Bucket of quartz for transport, laminar and approach to hydrodynamic processes. Count absolute volumetric true' (TVAC) - for the cell count and absolute Software PC with Windows ™, the current standard of the industry Operating system Microsoft WindowsTM 7 Professional 32-bit LCD screen color TFT 22 " Software FloMax for acquisition and evaluation of data in real-time. Data format: Standard flow cytometry (FCS) 2.0 and 3.0

€60,868.02 ex VAT
Spain
light sources, software
Agilent 1260 Fluorescence Detector-cover
Agilent 1260 Fluorescence Detector

Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Firmware A.07.02 8 ul Flow Cell. K (more)eeps original packaging. The FLD provides quantitative data and fluorescence spectra from a single run. Simultaneous detection of multiple wavelengths improves sensitivity and selectivity. Features include: Rotating gratings for on-line, multi-signal spectral data acquisition without loss of sensitivity. Lower limits of detection with Raman S/N > 3000 (using dark signal noise reference). Spectra and quantitative data from a single run. Simplified optical design to optimize baseline stability. Resolution gain of up to 100% in fast LC using 145 Hz data acquisition rate. Long life xenon lamp for maximum sensitivity. Long life flash lamp (> 4000 hours). Easy front access allows quick inspection or change of the flow cell. Agilent Infinity 1260 Fluorescence Detector (FLD) G1321B Spectra. Lower detection limits and easier spectral analysis for HPLC and UHPLC. As a stand-alone detector or configured in an automated system, the Agilent 1260 Infinity Spectra Fluorescence Detector brings highly sensitive fluorescence detection to your lab. This easy-to-use detector provides quantitative data and fluorescence spectra from a single signal. Simultaneous multiple wavelength detection improves sensitivity and selectivity. Use online spectral information for rapid method optimization and separation quality verification. High-speed fluorescence detection data processing up to 145Hz, keeping pace with ultra-fast LC analysis speed.

€8,750.00 ex VAT
Spain
optical detectors
Waters 2475 Multi-Wavelength Fluorescence Detector-cover
Waters 2475 Multi-Wavelength Fluorescence Detector

For sale: refurbished Waters 2475 Multi-Wavelength Fluorescence Detector   Also available: Waters 26 (more)95 Alliance HPLC systems Other Waters Detectors Parts for 2475 detector Complete Waters HPLC systems   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! We can deliver maintenance and repair services for Waters Alliance systems by our own engineers   The Waters 2475 Fluorescence Detector offers unsurpassed sensitivity for quantifying low concentrations of target compounds, whether naturally fluorescent or derivatized with a fluorescent tag. The 2475 FLR Detector sets the standard for fluorescence method development with 3D and “on-the-fly” spectral scanning for determining the optimal emission and excitation wavelengths, and has the ability to monitor up to four independent wavelength pairs.   Features: Innovative axially illuminated flow cell designed for less dispersion, less stray light, less volume, and more pathlength for maximum sensitivity Three-dimensional spectral scanning for faster method development and optimization, and enhanced peak identification Single or multi-channel operation monitors fluorescence at one or more discrete wavelength pairs Low noise performance – Less stray light due to orthogonal optics and the use of mirrors, not lenses, minimize scatter Multiple detection modes – 2D, 3D, and on-the-fly spectral scanning – can greatly reduce the time needed to develop fluorescence detection methods by quickly determining wavelength maxima Integral erbium calibration reference – ensures wavelength accuracy Normalized emission units for better bench-to-bench reproducibility Attribute Specification Wavelength range Ex: 200 to 890 nm Em: 210 to 900 nm Bandwidth 20 nm (maximum) Wavelength accuracy +3 nm Wavelength repeatability +0.25 nm Sensitivity, single channel  Ex: 350 nm Em: 397 nm (Single-to-noise ratio of water Raman peak >1000. Hamming filter TC = 1.5 sec) Sensitivity setting range 1 to 100,000 EUFS Filter setting range Side-channel: 0.1 to 5.0 seconds, Hamming (default) 0.1 to 99 seconds, RC multichannel: 1 to 50 seconds, hamming (default) 1 to 99 seconds, RC

€4,500.00 ex VAT
Netherlands
optical detectors
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]