Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics

General testing and measurement equipment

Memmert HCP150 Humidity Chamber 156L, 115V-cover
Memmert HCP150 Humidity Chamber 156L, 115V

Memmert HCP150 Humidity Chamber 156L, 115V Temperature Range Ambient +7°C to 90°C Humidity Control  (more)20 to 95% RH, or no RH Chamber Volume 156L (5.5 cu. ft.) Features - Ideal for climate and temperature testing, including accelerated life and 85/85 tests - Unsurpassed temperature and humidity uniformity across the chamber interior - Easy-to-use ControlCOCKPIT interface and AtmoCONTROL software for intuitive programming - Durable stainless steel construction that’s scratch-resistant and easy to clean - Six-sided heating, including heated inner glass door, to prevent condensation - Aluminum thermal layer for optimal temperature distribution and energy retention - Battery-buffered ControlCOCKPIT and optional MobileALERT for enhanced monitoring - Wide range of customizable test parameters for environmental simulation - Rear-panel feed-through and process runtime delay for precise test control - Comprehensive alarm functions and three-fold overtemperature protection for sample safety The Memmert HCP150 Humidity Chamber 156L, 115V is engineered to deliver precise climate and temperature control, making it ideal for a wide range of environmental and accelerated life tests, including the rigorous 85/85 tests. Offering a temperature range from Ambient +7°C to 90°C and active humidity control from 20% to 95% RH, this chamber creates a stable and highly customizable testing environment with an exceptional homogeneity of temperature and humidity throughout. Designed with Memmert’s user-friendly ControlCOCKPIT interface and the advanced AtmoCONTROL software, it features intuitive “Touch, turn & go” operation, allowing for straightforward programming of complex test parameters. Constructed with robust stainless steel that is scratch-resistant and hygienic, the HCP150 is built to withstand extensive use while maintaining a sleek, easy-to-clean design. Its advanced heating concept includes heating elements on all six sides and a heated inner glass door to prevent condensation and ensure uniform conditions. An integrated aluminum thermal conductive layer aids in maintaining optimal temperature distribution, while also providing a heat reservoir in case of power fluctuations. The chamber’s efficient humidity control prevents condensation buildup, protecting sensitive samples and reducing maintenance requirements. To support continuous and demanding tests, the HCP150 includes various convenience features like a rear-panel feed-through, battery-buffered ControlCOCKPIT for enhanced security, and optional MobileALERT for remote monitoring of alarm conditions via email or SMS. Additional safety features include three-fold overtemperature protection and real-time display of all essential parameters. With comprehensive programming options, reliable alarm functions, and precise environmental simulation, the Memmert HCP150 ensures both safety and accuracy, providing an optimal solution for laboratories focused on climate and temperature testing. INCLUDED: The Memmert HCP150 Humidity Chamber 156L, 115V includes: - 2 x Stainless Steel Perforated Shelves - Water Tank - 2 x Sponge Plugs for Silicone Entry Ports - USB Drive w/ Software & AtmoCONTROL Manual - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$16,944.00 ex VAT
United States
environmental chambers, climate controlled cabinets & enclosures
Memmert HCP105 Humidity Chamber 107L, 115V-cover
Memmert HCP105 Humidity Chamber 107L, 115V

Memmert HCP105 Humidity Chamber 107L, 115V Temperature Range Ambient +7°C to 90°C Humidity Control  (more)20 to 95% RH, or no RH Chamber Volume 107L (3.8 cu. ft.) Features - Ideal for climate and temperature testing, including accelerated life and 85/85 tests - Unsurpassed temperature and humidity uniformity across the chamber interior - Easy-to-use ControlCOCKPIT interface and AtmoCONTROL software for intuitive programming - Durable stainless steel construction that’s scratch-resistant and easy to clean - Six-sided heating, including heated inner glass door, to prevent condensation - Aluminum thermal layer for optimal temperature distribution and energy retention - Battery-buffered ControlCOCKPIT and optional MobileALERT for enhanced monitoring - Wide range of customizable test parameters for environmental simulation - Rear-panel feed-through and process runtime delay for precise test control - Comprehensive alarm functions and three-fold overtemperature protection for sample safety The Memmert HCP105 Humidity Chamber 107L, 115V is engineered to deliver precise climate and temperature control, making it ideal for a wide range of environmental and accelerated life tests, including the rigorous 85/85 tests. Offering a temperature range from Ambient +7°C to 90°C and active humidity control from 20% to 95% RH, this chamber creates a stable and highly customizable testing environment with an exceptional homogeneity of temperature and humidity throughout. Designed with Memmert’s user-friendly ControlCOCKPIT interface and the advanced AtmoCONTROL software, it features intuitive “Touch, turn & go” operation, allowing for straightforward programming of complex test parameters. Constructed with robust stainless steel that is scratch-resistant and hygienic, the HCP105 is built to withstand extensive use while maintaining a sleek, easy-to-clean design. Its advanced heating concept includes heating elements on all six sides and a heated inner glass door to prevent condensation and ensure uniform conditions. An integrated aluminum thermal conductive layer aids in maintaining optimal temperature distribution, while also providing a heat reservoir in case of power fluctuations. The chamber’s efficient humidity control prevents condensation buildup, protecting sensitive samples and reducing maintenance requirements. To support continuous and demanding tests, the HCP105 includes various convenience features like a rear-panel feed-through, battery-buffered ControlCOCKPIT for enhanced security, and optional MobileALERT for remote monitoring of alarm conditions via email or SMS. Additional safety features include three-fold overtemperature protection and real-time display of all essential parameters. With comprehensive programming options, reliable alarm functions, and precise environmental simulation, the Memmert HCP105 ensures both safety and accuracy, providing an optimal solution for laboratories focused on climate and temperature testing. INCLUDED: The Memmert HCP105 Humidity Chamber 107L, 115V includes: - 2 x Stainless Steel Perforated Shelves - Water Tank - 2 x Sponge Plugs for Silicone Entry Ports - USB Drive w/ Software & AtmoCONTROL Manual - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$13,160.00 ex VAT
United States
climate controlled cabinets & enclosures, environmental chambers
Radwag PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale-cover
Radwag PM02.EX-2-2 Intrinsically Safe Power Supply Intended for Ex Scale

The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to  (more)power the HRP.EX. PM02.EX power supply comes in two designs: PM02.EX-1-2: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator. PM01.EX power supply comes in two designs: PM01.EX-1: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

€800.00 ex VAT
Poland
industrial scales accessories, power supplies, scales for ex areas, weighing terminals
Radwag PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale-cover
Radwag PM02.EX-1-2 Intrinsically Safe Power Supply Intended for Ex Scale

The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to  (more)power the HRP.EX. PM02.EX power supply comes in two designs: PM02.EX-1-2: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to power the HX5.EX indicator. PM01.EX power supply comes in two designs: PM01.EX-1: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

€786.00 ex VAT
Poland
weighing terminals, industrial scales accessories, scales for ex areas, power supplies
Radwag PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale-cover
Radwag PM01.EX-2 Intrinsically Safe Power Supply Intended for Ex Scale

The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to  (more)power the HX5.EX indicator. PM01.EX power supply comes in two designs: PM01.EX-1: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX. PM02.EX power supply comes in two designs: PM02.EX-1-2: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

€828.00 ex VAT
Poland
industrial scales accessories, power supplies, scales for ex areas, weighing terminals
Radwag PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale-cover
Radwag PM01.EX-1 Intrinsically Safe Power Supply Intended for Ex Scale

The certified intrinsically safe PM01.EX power supply, manufactured by RADWAG, has been designed to  (more)power the HX5.EX terminal. PM01.EX power supply comes in two designs: PM01.EX-1: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM01.EX-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. The certified intrinsically safe PM02.EX power supply, manufactured by RADWAG, has been designed to power the HRP.EX. PM02.EX power supply comes in two designs: PM02.EX-1-2: power supply intended for operation in hazardous area: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in: Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.

€786.00 ex VAT
Poland
power supplies, industrial scales accessories, weighing terminals, scales for ex areas
Benchmark E1200-PSP myGel InstaView Package: E1200 and E2301 touch screen power supply-cover
Benchmark E1200-PSP myGel InstaView Package: E1200 and E2301 touch screen power supply

Benchmark E1200-PSP myGel InstaView Package: E1200 and E2301 touch screen power supply For labs that (more) prefer to use a separate power supply, the InstaView Gel Tank is the perfect choice for running, viewing and documenting electrophoretic separations. The InstaView Gel Tank accommodates one large (10.5x10cm) or one small (10.5x6cm) gel tray and is supplied with trays, combs and a leak-proof casting stand. The gel tank lid includes attached power leads which prevent the unit from operating without the lid properly in place. The InstaView Gel Tank is shaped to allow the mini LED transilluminator (included) to slide underneath. Blue light, at a wavelength of 465nm, provides excitation of common green fluorescent stains such as SmartGlow™, SYBR™ Green, and GelGreen. An orange filter is incorporated into the gel tank lid for visualizing the DNA in the gel box without any additional equipment or glasses. The transilluminator can be turned on at any time during a run to track progress, and automatically shuts off after 5 minutes. After electrophoresis, simply place the included imaging enclosure over the InstaView Gel Tank to capture high resolution images with a smart phone. Images are easily printed or shared via email or text message. The myVolt Touch is a work horse electrophoresis power supply, ideal for efficient separation of nucleic acids and proteins as well as basic western blotting applications. Four pairs of output jacks are wired in parallel for connecting multiple electrophoresis tanks. A color touch screen allows quick setting and monitoring of all run conditions, including run time, voltage, and current. Users can select “Constant Current” or “Constant Voltage” during an electrophoresis run, keeping the chosen parameter fixed as resistance changes. The dual orientation design with rotating display allows the myVolt Touch to be installed in the most convenient location, on a shelf or bench, saving valuable space. The myVolt Touch features a logical user interface. Setting up an electrophoresis run couldn’t be easier; simply touch the parameter to select it, press the “up” and “down” arrows to adjust the value, and then touch “Start”. All parameters are always displayed, with no need to toggle between Time, Voltage or Amperage. In addition the run status is always displayed. INCLUDED: The Benchmark E1200-PSP myGel InstaView Package: E1200 and E2301 touch screen power supply includes: - Gel Running Tank Assembly - Blue Light LED Illuminator - Gel Casting Stand - Gel Trays - Double Sided Comb - Power Supply - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$1,085.00 ex VAT
United States
power supplies
1...678
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]