Radwag 5Y.20.PM Precision Balance

Radwag€7,320.00 (ex VAT)
item image

Description by the supplier

Fast and Stable Measurement

It only takes a second for the balance to display the final measurement result.


Weighing Heavy Loads with High Accuracy

On the large weighing pan of a PM balance, you can weigh a load of 120 kg with a readability of 0.2 g and second-to-none repeatability.


Minimum Eccentricity Error Over the Entire Range

PM balances can be used to determine the mass of irregularly shaped components with a centre of gravity that is significantly shifted from the weighing pan axis.


Parameter Stability Over Time and After Transport

The mechanical design is resistant and robust, allowing you to maintain the correct metrological parameters after transport and despite long and intensive use.


Weighing Pan Dimensions Adapted to the Accuracy of the Balance

Weigh with the highest readability of 0.01 g on the 200 x 185 mm weighing pan and with a readability of 0.2 g on the 500 x 400 mm weighing pan.


21 CFR Part 11


Do you work in the pharmaceutical industry? Do you need a digital signature?


We are offering the laboratory balance which as a standalone fully meets the requirements of

21 CFR Part 11/ EU GMP Annex 11.


- Full data security


- Electronic signatures


- Validations


- Electronic records


- Audit trails


New, lmproved


The new, taller and larger MONOBLOCK®


enables the best repeatability and speed


in its class of weighing platforms.


5Y Terminal


With Terminal 5Y you get a 10-inch display, Digital Weighing Auditor, multi-step user


verification, ambient light alerts, hotspot, RFID*, live note voice and text notes, voice commands


for the balance and handy measurement history within the handy library widgets


Modbus TCP/IP


is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.


A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.


Under-pan weighing


Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook.


THBR 2.0 System


Cooperation with THBR 2.0 System for ambient conditions monitoring.


* RFID ISO/IEC 14443 Type A, 13,56 MHz

Product details
FunctionsAutotest, Dosing, Percent Weighing, Parts counting, Peak hold, Formulation, Newton unit measurement, Statistics, Checkweighing, IR sensors, Under-pan weighing, GLP Procedures, Animal weighing, Pipettes Calibration, Air density correction, Density determination, Differential weighing, Ambient conditions monitoring, Statistical Quality Control, Packaged Goods Control, ALIBI Memory, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag E2 Mass Standard - Stainless Steel Wire -500 mg-cover
Radwag E2 Mass Standard - Stainless Steel Wire -500 mg

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed  (more)as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class standard: stainless steel wire Nominal value: 500 mg Material: stainless steel High Precision of measurements The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component. Stability over Time An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. Applications 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€59.00 ex VAT
Poland
mass standards
Radwag MWMH 1000-TWD Electromagnetic Compensation Weighing Module-cover
Radwag MWMH 1000-TWD Electromagnetic Compensation Weighing Module

MWMH series modules are not offered or distributed in the following countries: Germany, Switzerland, (more) Italy, Japan and the USA. Vast Max Capacity Range Magnetoelectric weighing modules MWMH are intended for mass measurement ranging from 1kg to 10kg. Minimum readability of 0.01g guarantees amazing accuracy for your measurement. Protection Against Challenging Conditions Hermetic versions of modules feature stainless steel housing with IP65 and IP69K. This allows operation even in the most challenging conditions. Mechanical design lacks sharp edges and gaps which ensures adherence to HACCP, GMP and FDA standards for safety and quality of operation. Fast and Precise Measurement High measurement accuracy with sd=1d* guarantees both readout of real weighing results and repeatability of indications. Cutting-edge design solutions provide fast measurement which is an asset allowing to install the module on automated production lines. Intended for fast and dynamic measuring processes the weighing module’s converter throughput is 3200 meas./s. Cooperation with terminals Connecting the module to a multifunctional weighing terminal expands communication interfaces range and increases usage in industrial applications. Mechanical design versions: MWMH xxx - 1 - model with Binder connectors (IP65), MWMH xxx - 2 - model with Binder connectors, (IP65), power supply and control of the transporter on a weighing pan, MWMH xxx - 3 - model with cable glands, (IP 69K), MWMH xxx - 4 - model with cable glands (IP69K), power supply and control of the transporter on a weighing pan MWMH xxx - TWD - model with cable glands (IP 69K).

Poland
weighing modules
Radwag MA 50/1.5Y.WH Moisture Analyzer-cover
Radwag MA 50/1.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
balances, moisture analysers
People are watching right now:
Motic BA310 MET-T Trinocular  (Stroke 6 x 4 Stage)-cover
Motic BA310 MET-T Trinocular (Stroke 6 x 4 Stage)

Motic BA310 MET-T Trinocular (Stroke 6”x 4” Stage) Motic’s BA310MET series presents a powerful micro (more)scope line for incident light applications in all material sciences. Industrial quality control of opaque samples can be performed as well as teaching in educational environments of engineering and material professions, where affordability and ease of use are key demands. Extended flexibility is given by the BA310MET-T models with built-in transmitted light for transparent or compound materials. The BA310MET-H includes a more flexible focusing device, dedicated to larger samples with little limitation in size. Motic's LM Plan-Achromatic objectives with Long-Working Distance for incident light provide optimal image contrast for reflective, non-covered specimen. Together with a fully corrected tube lens an intermediate image without colored fringes is created. In all models the Epi-Illuminator offers a powerful 50W Halogen light source. The built-in field diaphragm and aperture diaphragm help to optimize image quality by reducing stray light and thus increasing contrast.INCLUDED: The Motic BA310 MET-T Trinocular (Stroke 6”x 4” Stage) includes: - 5X/0.13 (WD 20.3mm) Objective - 10X/0.25 (WD 17.5mm) Objective - 20X/0.40 (WD 8.1mm) Objective - 50X/0.55 (WD 8.4mm) Objective - Widefield N-WF10X/20mm with Diopter Adjustment - Dust Cover - Power Cord - Allen Key - Blue, Frosted, Green and Yellow Filters - Operator's Guide Motic BA310 MET-T Trinocular (Stroke 6”x 4” Stage) SpecificationsModelBA310MET-H Trinocular (6"x4")Optical systemColour Corrected Infinity Optical System (CCIS®)Observation tubeTrinocular head, Siedentopf type, 360° SwivelingInclination30° inclinedTrinocular light split100:0/20:80Interpupillary distance48-75mmDiopter adjustmentOn both eyepieces, +/- 5 diopterEyepiecesWidefield N-WF10X/20mm with diopter adjustmentIntermediate bodyEpi-illuminator quartz halogen with integrated field and aperture diaphragms and external lamphouseNosepieceReversed quintupleObjective classificationCCIS® LM Plan Achromatic, DINObjectives5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)Objective mounting threadW 4/5"x1/36" (RMS standard)Stand typeUprightStageMechanical stage, hard coated with built-in low position coaxial stage control and glass plateStage size300x180mmTravel range X&Y150x100mm (6"x4")CondenserFocusable and centerable Abbe condenser N.A. 0.85DiaphragmIris diaphragmFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentFine focus precision2μmFocusing stroke30mmUpper limit stopUpper limit stop preset but adjustableFilter holderOn top of the illuminator with fixing capIncident illuminationQuartz halogen 12V/50W with integrated field and aperture diaphragmsTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlIllumination interchangeabilityEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WIllumination featuresExternal lamp house for Epi-illuminatorTransformerEpi-illuminator external, transmitted internalPower supply100-240V (CE)Dimensions LxWxH508x240x465mmNet weight12.7kgComparison of ModelsSpecificationMotic BA310 MET BinocularMotic BA310 MET TrinocularMotic BA310 MET-H TrinocularMotic BA310 MET-H Trinocular (Erect Image)Motic BA310 MET-T Trinocular (3"x2" Stage)Motic BA310 MET-T Trinocular (6"x4" Stage)Motic BA310 MET-T Trinocular (Erect Image)Motic BA310 MET-T Trinocular (Stroke 3”x 2” Stage) (Erect Image)Observation TubeBinocular headTrinocular headTrinocular headTrinocular head (Erect Image)Trinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingInterpupillary Distance48-75mm48-75mm55-75mm55-75mm48-75mm48-75mm48-75mm48-75mmObjective ClassificationCCIS® EC Plan Achromatic, DINCCIS® EC Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® EC Plan Achromatic, DINCCIS® LM Plan Achromatic, DINObjectives5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 11.5mm), 10X/0.3 (WD 6.8mm), 20X/0.40 (WD 11.1mm), 50X/0.55 (WD 8.2mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)StageMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with built-in low position coaxial stage control and glass plateMechanical stage, hard coated with built-in low position coaxial stage control and glass plateMechanical stage, hard coated with built-in low position coaxial stage controlMechanical stage, hard coated with built-in low position coaxial stage control and glass plateStage Size180x140mm180x140mm180x140mm180x140mm240x140mm300x180mm180x140mm240x140mmTravel Range X&Y75x50mm75x50mm100x80mm100x80mm75x50mm150x100mm75x50mm75x50mmIllumination InterchangeabilityQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WQuartz halogen 12V/50W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3W.comparison-table tr td:nth-child(7) { background-color: #fffacd; }DownloadsTechnical Specification Download Operator's Manual Download

$4,441.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]