Perkin Elmer 343 Polarimeter

€5,999.00 (ex VAT)
item image

Description from the supplier

The Perkin Elmer 343 Polarimeter, a reliable second-hand system, offers cutting-edge polarimetry capabilities essential for the thorough investigation and evaluation of optically active substances. This instrument is vital across several applications, including:

  • Characterization of newly synthesized compounds
  • Quality control processes within pharmaceutical manufacturing
  • Precise quantitative analyses of sugars
  • Selective detection of optically active components via HPLC
  • Monitoring and regulation of enzymatic reactions

Key Features:

  • **Principle:** The device is an automatic precision polarimeter operating on the optical null principle through analyzer rotation and equipped with automatic gain control.
  • **Radiation Source:** Na spectral lamp provides consistent illumination.
  • **Spectral Lines:** Accessible via the instrument's keypad, offering Na 589 nm lines.
  • **Apertures:** Customizable apertures to accommodate both standard cells and microcells.
  • **Detector:** Employs a 1P28A photomultiplier for accurate measurement.
  • **Polarizers:** Utilizes visible-transmitting polarizers for precise optical analysis.
  • **Rotatory Range:** An extensive rotatory range of ± 85° is available.
  • **Balancing Speed:** Operates at a balancing speed of 1.3°/s at 50 Hz and 1.5°/s at 60 Hz.
  • **Accuracy:** Delivers exceptional accuracy, with ± 0.002° for rotations up to 1º and ± 0.2% for rotations exceeding 1°.
  • **Reproducibility:** Offers reliability better than 0.002° for both zero and rotational readings.
  • **Internal Angular Resolution:** Fine resolution at 1 x 10⁻⁴ º.
  • **Integration Times:** Versatile integration times ranging from 0.1s to 100s.
  • **Autozero Setting:** Easily set electronically through the keypad at any position within the rotatory range.
  • **User Interaction:** Features both menu-driven interaction via integrated touch-keys in multiple languages (English, German, French, Spanish, and Italian), and PC integration through POL WinLab or POL WinLab ES software.
  • **Display:** Equipped with a vacuum fluorescence display for standalone operation, featuring two lines accommodating 20 characters each.
  • **Result Formats:** Results are customizable via the keypad, allowing outputs in angular rotation, specific rotation, molar rotation, international sugar scale, or a user-defined scale with specified factors and offsets.
  • **Physical Specifications:** Dimensions are 825 x 310 x 390 mm, with a total weight of 40 kg.

This polarimeter stands as a sophisticated tool engineered for precise optical measurements and analyses, supporting a wide array of research and quality control applications.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Perkin Elmer 343 Polarimeter-cover
Perkin Elmer 343 Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
Perkin Elmer Model 343 S Polarimeter-cover
Perkin Elmer Model 343 S Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]