Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
not_applicable
Categories

BELLINGHAM + STANLEY Automatic polarimeter ADP410

Biomatyx
item image

Description by the supplier

BELLINGHAM + STANLEY Automatic polarimeter ADP410

ADP410 automatic polarimeter

Model 37-410

Simple and precise ±0.02°

Result in 15 seconds

2-point calibration, zero and value of your choice

Included with temperature probe

Without 200mm tube with central filling

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Perkin Elmer 343 Polarimeter-cover
Perkin Elmer 343 Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
Perkin Elmer Model 343 S Polarimeter-cover
Perkin Elmer Model 343 S Polarimeter

Polarimetry is an important technique for the investigation and analysis of optically active substan (more)ces. Common applications include: Characterization of newly synthesized compounds Quality control of pharmaceutical drugs Precise quantitative analysis of sugars Selective detection of optically active components by HPLC Monitoring and control of enzymatic reactions Principle: Automatic precision Polarimeter with optical null principle by rotation of the analyzer; automatic gain control. Radiation: Na spectral lamp Spectral lines: Selectable from instrument keypad (Na 589 nm) Apertures: Selectable apertures for standard cells and microcells. Detector: Photomultiplier 1P28A. Polarizer and analyzer: Vis-transmitting polarizers Rotatory range: ± 85° Balancing speed: 1.3°/s at 50 Hz; 1.5°/s at 60 Hz. Accuracy: ± 0.002° for rotations ≤1º; ± 0.2% for rotations >1° Reproducibility: Better than 0.002° (for zero and rotational reading). Internal angular resolution: 1 x 10-4 º Integration times: 0.1s, 0.2s, 0.5s, 1s, 2s, 5s, 10s, 20s, 50s and 100s. Autozero setting: Electronically from instrument keypad at any desired position in the rotatory range. User interaction: Either menu-driven from integrated touch-keys (English, German, French, Spanish and Italian), or PC-controlled from POL WinLab or POL WinLab ES software. Display: Stand-alone operation: vacuum fluorescence display, two lines with 20 characters each. Format of results: Selectable from instrument keypad – angular rotation, specific rotation, molar rotation, international sugar scale, user-defined scale with factor and offset. Dimensions (WxHxD): 825 x 310 x 390 mm Weight: 40 kg

€5,999.00 ex VAT
Netherlands
polarimeter, polarimeters
People are watching right now:
Wet gas vacuum pump Laboport SD N 820.3 FT.40.18 KNF-cover
Wet gas vacuum pump Laboport SD N 820.3 FT.40.18 KNF

The N 820.3 FT.40.18 is a two-stage pump with an integrated “self-drying” system for automatic conde (more)nsate drain. The “SD” series is widely used in laboratories, especially when the vapors are humid and a clean and ecological vacuum is required. Typical applications are: vacuum ovens (for drying chemicals, drying biological samples, heat treatments), autoclaves for sterilizing instruments, containers, filters and textiles. Thanks to the use of anti-corrosion materials, it is possible to vacuum even corrosive products.  The heart of the pump is the diaphragm with differentiated structure in PTFE, optimized to guarantee high performance with reduced dimensions and at the same time, long life even in heavy applications.  When the humid gases are sucked in, condensation may form in the pump head: consequently the performance decreases, considerably increasing the emptying time. To eliminate condensation, the 'drying system' then opens a solenoid valve that allows ambient air to enter the heads. Once the condensation has been eliminated, the solenoid valve closes and the pump sucks from the stove in full capacity. Over time, condensation could form again and then the cycle is repeated. The time interval between one cycle and the next can be adjusted as desired, as well as the duration of the air injection. Technical features Flow rate (max.) 20 l / min Final vacuum (max.) 10 mbar (abs.) Pressure (max.) 1 bar (rel.) Fluid temperature allowed at 5-40°C FFPM valve material PTFE coated diaphragm material Pump head material PTFE Applications Rotary evaporation Vacuum oven Qualitative characteristics Clean operation, 100% oil-free Corrosion resistant PTFE / FFPM flow path Ideal for extremely aggressive / corrosive gases and vapors Compact, silent and reliable The self-drying system removes condensation without altering the vacuum level Maintenance free Download the data sheet for further information and accessories. NOT SURE WHICH VACUUM PUMPS YOU NEED? Try following our guide to KNF pumps: VACUUM PUMPS FOR THE LABORATORY Or download the KNF guide: THE IDEAL DIAPHRAGM PUMP FOR EVERY APPLICATION

€1,990.00 ex VAT
€2,368.10 incl. VAT if applicable
Italy
pumps liquid & other, vacuum pumps
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]