Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Olympus
Model
Olympus BX61
Supplier
Unigreenscheme
Location
Caerphilly - United Kingdom
Price
£5,000.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Olympus BX61 Microscope With BX-UCB And U-HSTR2 Control Units Lab

Unigreenscheme£5,000.00 (ex VAT)
item image

1 / 28
Description by the supplier

Olympus BX61 Microscope With BX-UCB And U-HSTR2 Control Units

This microscope system was removed from a university where it was surplus to requirement.

All units are in good cosmetic condition and in good working order.

The items included are as follows:

1 x Olympus BX61 Microscope Model: BX61TRF.Serial No 7M25426

1 x Olympus BX-UCB.Serial No. 0D07119

1 x Olympus U-HSTR2.Serial No. 2E16101

1 x Olympus U-LH100-3 Light UnitSerial No. 7J12122

2 x Olympus WHN10x/22 Eyepiece.

1 x PlanApo N 60x/1.42 oil /17/FN26.5.1 x UplanSApo 100x/1.40 oil/17/FN26.5.1 x UPlanFL N 10x /0.30 /FN26.5.1 x PlanApo N 1.25 x/0.04 /FN26.5.2 x data cables

Product details
Electrical SupplyN/A
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Olympus Fluoview FV1000 System - Incomplete System - No Microscope Lab-cover
Olympus Fluoview FV1000 System - Incomplete System - No Microscope Lab

This Olympus Fluoview FV1000 System was removed from a university lab where it was surplus to requir (more)ements. Included are; 1x Olympus FluoviewModel FV1000 The unit is in good cosmetic condition, but the power cables were missing so it has not been tested. The included PC powers up and has Olympus FV10-ASW Version 01.06.00.13 installed. 1x Olympus Transmitted Light Detector:Model FV10-TDThe unit is in good cosmetic condition. 1x Olympus Control Box:Model IX2 UCBThe unit powers on and is in good cosmetic condition. 1x Olympus Power Supply:Model FV10-PSUThe unit powers on and is in good cosmetic condition. 1x FV10-PSU Key:Model 1201 The unit is in good cosmetic condition. 1x Olympus Hand-switch:Model U-HSTR2The item powers on and is in a reasonable, used cosmetic condition. 1x Olympus Laser Diode Interface Controller:Model FV10-LDIFThe unit is in good cosmetic condition. The PSU is missing. 1x Olympus Power Supply:Model U-RFL-T200Life Time: 3667 hoursThe unit powers on and is in good cosmetic condition. It is not known if the Burner has been replaced after 200 hours. 1x Olympus Mercury Light Source:Model U-LH100GThe unit powers on and is in good cosmetic condition. The Lamp is working. 1x Olympus Light Source StandModel FV10-FIRThe unit is in good cosmetic condition. There are some scuffs and scratches from general use. 1x Olympus Power Supply:Model FV5-LDPSURunning hours: 79335.3 The unit powers on and is in good cosmetic condition.I was unable to connect the head to the power supply as there is no cable that comes with the two units. 1x FV5-LDPSU Olympus Power Supply Key:Model 1201The unit is snapped. However, FV10-PSU key is the same model and fits the barrel of the FV5-LDPSU Olympus power supply. 1x Olympus Laser HeadModel LD405The unit is in good cosmetic condition.I was unable to connect the head to the power supply as there is no cable that comes with the two units, I could not test whether the laser head is responsive to the power supply. 1x IW-R3000N Rack Mountable Server ChassisThe unit powers on and is in good cosmetic condition. Accessories: 1x Olympus objective correction capModel CAP-G0.5 ± 0.5The unit is in good cosmetic condition 1x Olympus Laser safety shutterModel F10-SHAUXThe unit is in good cosmetic condition. 1x Olympus Goose neck fibre optic light pipesModel LGS3F1200UVThe unit is in good cosmetic condition. Spacers: 2x L3cm xW3cm xH0.5cm 2x L4cm x W4cm x H0.5cm The units are in good cosmetic condition. Misc Accessories: 1x IW-R3000N Rack Mountable Server Chassis User manual V2.11x Microsoft Windows 2000 XP professional Inst/uninst CD1x Belkin Serial Adaptor 1x RCA Phono male to male cable (sealed)1x SATA Cable (C13214-001 FOXCON 0550)1x 9 PIN S -Video to 3 RCA RGB TV HDTV adaptor cable 1x ATX 4 Pin Male to 8 Pin Female EPS power cable cord adaptor1x RCA Female to mini DIN 8-PIN connector (sealed)1x VGA to DVI connector (sealed) Installation discs:2x Belkin USB Adaptor Installation1x Intel Express installer1x Sapphire installation driver 1x mini disc

£3,785.00 ex VAT
United Kingdom
microscopes
Ohaus a-AP50MM-B Photometer-cover
Ohaus a-AP50MM-B Photometer

Ohaus a-AP50MM-B Photometer Fixed Wavelength 365 nm; 420 nm; 455 nm; 525 nm; 560 nm; 570 nm; 630 nm  (more)Photometric Measuring Range 0 Abs to 1 Abs Wavelength Accuracy ±1.0nm Features - The AP50MM is equipped with a real-time dynamic display for eachmeasurement, to provide fast, reliable results - Can record up to 30,000 datapointswith time and date stamp - Built-in calibration curves provide automatic selection of appropriatewavelengths from the long-lasting LED light source, store commonly used tests for efficiency - Large, backlit display makes it easier to read real-time results - Fixed wavelengths: 365 nm, 420 nm, 455 nm, 525 nm, 560 nm, 570 nm, 630 nm - Turbidity optical system based on nephelometric measurement - Photometric accuracy of ± 0.005 Abs at 1.0 Abs nominal - Compact and lightweight design weighing only 1.32 lb (0.6 kg) - Operates on 4 AA (LR6) batteries with a typical life of 6 months The Ohaus a-AP50MM-B Photometer is a standalone, multifunctional device designed for fast and reliable colorimetric and turbidity measurements in field applications. Engineered with a compact, rugged design, this photometer provides exceptional performance with a real-time dynamic display for each measurement, allowing for precise and efficient analysis. Capable of storing up to 30,000 data points with time and date stamps, it ensures seamless data management for professional use. The a-AP50MM-B features built-in calibration curves that automatically select the optimal wavelength from its advanced LED light source, including near-UV at 365 nm, making it highly versatile for various testing requirements. A large, backlit graphical LCD offers clear visibility of results, even in low-light conditions, while the device’s nephelometric turbidity optical system ensures accurate measurements ranging from 0 to 200 NTU. With its lightweight construction at just 1.32 lbs and operation powered by 4 AA batteries lasting up to six months, the a-AP50MM-B is perfect for on-the-go applications. While this model does not include additional accessories like the a-AP50MM-F, it delivers all the essential features for high-quality analysis, making it a reliable choice for water sample testing in diverse environments. INCLUDED: The Ohaus a-AP50MM-B Photometer includes: - >Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$1,600.00 ex VAT
United States
microscopes, microscope accessories
People are watching right now:
SCANDITRONIX WELLHOFER Darklight Duo Sensitometer Densitometer X-Ray Constancy-cover
SCANDITRONIX WELLHOFER Darklight Duo Sensitometer Densitometer X-Ray Constancy

one dual function SENSITOMETER and DENSITOMETERManuf: IBA- Scanditronix / Wellhöfer Model: darklight (more) duo Description:combined dual function instrument for the constancy tests in X-Ray film processing or other similar applicationsmicroprocessor - controlled with digital display of all parameters and memory for processes power supply...................4 AA - Alkaline Batteriesor  with included Special  Power Supply for input 230 VAC Mains SPECIFICATIONS SENSITOMETERcolour....................................................................blue --- green selectablepeak wavelength................................................blue = 460 nm........green = 510 nm ..... both ( +/- 10 nm )light exposition.................................................. in 5 steps selectable ( separate for each colour )reproduce accuracy.......................................... +/- 0.02 log exposurelong time stability................................................ +/- 0.02 log exposurecalibration............................................................. +/- 0.04 log exposuregrayscale.............................................................. 21 - steps ..............0.15 log light exposureaccuracy of steps................................................ 0.05 %homogenity........................................................... +/- 0.01 log exposure SPECIFICATIONS DENSITOMETERvisual optical density.......................................... followg. DIN 4512 / ANSI PH 2.19 - 1976.........internal light sourcefocus opening......................................................  3 mmmeasuring range.................................................  from  D = 0 to D = 5.0accuracy and reproduceability......................... 0.02 D instrument is in unused excellent cosmetic condition and 100 % functional testedcomes  D = 2.90 ( nominal )  Standard Calibration Filmcomes with german manual

€400.00 ex VAT
€476.00 incl. VAT if applicable
Germany
general laboratory equipment other
SRI 8610C GC Gas Chromatograph System Lab-cover
SRI 8610C GC Gas Chromatograph System Lab

Reason for return - Investigate faults and re-list accordingly: - We received the item with a cracke (more)d glass piece to the photoionization detector. We replaced it with a piece that was provided. - We piped the system with N2 carrier gas and gas lines carrying product to the inlet of the GC. We turned on the switch to the Photoionization detector, under high sensitivity, and can visibly see it turn on. The source is aligned. The detector is aligned.  - We programmed the event on the software to turn the valve of the 10-way valve accordingly to enable the carrier gas to bring the product through the GC. - We introduced acetone via the sample loop (inlet gas) - we saw no peaks. We introduced acetone via injection - we saw no peaks.  - I leaked checked the piping including within the detector - no issues. I checked the point of outlets to make sure flow is continuous too - no issues. - The mechanism of the valve turning - it made a cranky sound, and I am not convinced it is turning the valve.  - There may be two issues. I had figured it was the valve so I tried injecting acetone directly into the line, but we could not see any peak of acetone. (Issues with the detector?) I am not sure if the valve's squeaking/cranky sound implies it is turning but there might be an issue here too. This SRI 8610C GC Gas Chromatograph System was removed from a university lab where it was surplus to requirements. The unit powers up but we were unable to test it further at our facility. The lab did confirm however, that is in good working order. It is in very good cosmetic condition with only very minor marks from use.

£1,540.00 ex VAT
United Kingdom
gc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]