Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Leica
Model
Leica DC 300F
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€1,500.00 
(€1,785.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 20,00 kg

Categories

Leica 11505297 Basic Documentation Tube MBDT motorized 19 CIP NEW

PROFCONTROL GmbH€1,500.00 
(€1,785.00 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Shimadzu MCE-202 MultiNA Microchip Electrophoresis System-cover
Shimadzu MCE-202 MultiNA Microchip Electrophoresis System

This system is used to analyze the size of DNA/RNA samples, with convenientanalytical operability. I (more)t achieves analysis costs on par with agarose gel electrophoresis, and can perform fully automatic analyses of up to 108 samples. Using optimized reagent kits (four types for DNA analysis and one type for RNA analysis), the system achieves a high resolution and high sensitivity. It can significantly improve the workflow for mutation checks in genome editing, and genotype determination. Sample rack: Compatible with 96-well PCR plate and 12/8-strip PCR tube (Shimadzu recommended product) Microchip: Quartz, 23 mm separation channel length, on-chip electrodes (insert up to four microchips) Pretreatment: Automatic sample injection, automatic separation buffer replenishing, automatic chip cleaning Electrophoresis Voltage: Max. rated voltage: 1.5 kV, max. current: 250 μA Analysis Cycle time: Approx. 80 s (using four chips) DNA standard analysis (DNA-1000/premixed). This does not include time required for carrying out the first and final wash and initial analysis. Detection Method: LED-excited fluorescence detector (470 nm excitation wavelength) Separation Size Range: 25 to 500 bp (DNA-500 Kit), 100 to 1000 bp (DNA-1000 Kit), 100 to 2500 bp (DNA-2500 Kit), 100 to 12000 bp (DNA-12000 Kit), Up to 28S rRNA (5.0 knt) (RNA Kit) Resolution: 5 bp (25 to100 bp), 5% (100 to 500 bp), 10% (500 to 1000 bp), 20% (1000 to 12000 bp) Sizing Accuracy: ±5 bp (25 to 100 bp), ±5% (100 to 500 bp), ±15% (DNA-1000, DNA-2500, DNA-12000) Required Sample Volume: DNA analysis: Premix mode: 2 to 10 μL (after mixing with marker solution: 6 to 30 μL), On-Chip Mixing mode: 5 to 30 μL, RNA analysis: Premix mode: 3 to 15 μL (after mixing with marker solution: 6 to 30 μL), In the Premix mode, the marker solution is mixed with the sample before loading in the instrument, In the On-Chip Mixing mode, the sample and marker solution are loaded separately and mixed on the microchip under program control. Maximum Salt Concentration: DNA analysis: 10mM Tris-HCI containing 125 mM KCl or NaCl max, RNA analysis: 10mM Tris-HCI, containing 1 mM EDTA max. Min. Detection Limit: DNA analysis: 0.2 ng/μL (at 10mM Tris-HCI buffer, containing 50 mM KCl and 1.5 mM MgCl2), RNA analysis: 5 ng/μL (total RNA), 25 ng/μL (mRNA) (at 10 mM Tris-HCI buffer, containing 1mM EDTA) Quantitation Range: DNA analysis: 0.5 to 50 ng/μL (at 10mM Tris-HCI, containing 50 mM KCl and 1.5 mM MgCl2), RNA analysis: 25 to 500 ng/μL (total RNA), 25 to 250 ng/μL (mRNA) (10 mM Tris-HCI buffer, containing 1 mM EDTA) Quantitation Accuracy: DNA analysis: ±30% (at 10 mM Tris-HCI buffer, containing 50 mM KCL) (DNA-500, DNA-1000, and DNA-2500 Kits), ±40 % (DNA-12000 kit. Quantitative accuracy is based on verification from 200 bp to 12000 bp.) Quantitation Repeatability: RNA analysis: CV 10% or less (CV 20% or less for eukaryotic-origin total RNA at concentrations of 150 ng/μL or more) Dimensions (WxDxH): 415 x 545 x 508 mm Weight: 43 kg

€4,499.00 ex VAT
Netherlands
electrophoresis
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]