Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Prolabo
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
used
Categories

Spinning top lift BOY 08 510.00 PROLABO 20 x 20 cm

Biomatyx
item image

Description by the supplier

Spinning top lift BOY 08 510.00 PROLABO 20 x 20 cm

Lifting support, lifting table for laboratory

Tabletop dimensions: 200 x 200 mm

With traces of wear

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Radwag 21 CFR Part 11 Compliance Module (4Y, 5Y, CY10)-cover
Radwag 21 CFR Part 11 Compliance Module (4Y, 5Y, CY10)

The 21 CFR Part 11 Compliance Module is a solution especially useful for those users who are obliged (more) to conform to provisions of 21 CFR Part 11 and EU GMP Part 4, Annex 11 regulations. These two documents determine the rules for using electronic records and signatures. Data protection is guaranteed by: advanced password settings, control of logging correctness, various permission levels, data management access, backup, electronic signature, time-defined automatic logout, modification record to Audit Trail file. The module includes "Audit Trail". Audit Trail is a kind of a log where all modifications of balance settings, changes in database records and user activity are recorded. Audit Trail, for example, keeps record of previous and new modifications in databases and informs by whom and when they were introduced. This log allows the administrator to track and find out who logged in, when, who signed a document or who used invalid password. The Audit Trail Reader freeware allows users, upon connection with a balance, to display Audit Trail log and manage it by generating reports of various formats: pdf, xls, csv, html.

€432.00 ex VAT
Poland
ultra microbalances, analytical balances, analytical balances accessories, balances, balances accessories, industrial scales accessories, mass comparators, mass comparators accessories, microbalances, microbalances accessories, moisture analysers, precision balances, precision balances accessories, scales, ultra & microbalances accessories
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml-cover
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml

XA11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA microbalance. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 11 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
balances accessories, microbalances, analytical balances, microbalances accessories, pipettes calibration, pipettes, scales, ultra & microbalances accessories, ultra microbalances, analytical balances accessories, balances
Radwag MA 50/1.R.NS Moisture Analyzer-cover
Radwag MA 50/1.R.NS Moisture Analyzer

Moisture analyzer is a laboratory measuring instrument intended to determine relative humidity for s (more)mall samples of different materials. MA.R series redefines moisture analyzers standards. The MA.R series This series has been equipped with brand new readable LCD display providing an extra text line for information such as supplementary messages and data, e.g. product name or tare value. The moisture analyzer, using respective pictograms, signalizes currently activated mode, computer connection and functions, both balance and service ones. The MA.R series is enriched with various interfaces: RS232, USB type A, USB type B and Wi-Fi. The moisture analyzer is housed in a plastic casing. Databases: Information system of R series moisture analyzers is based on 6 databases, allowing many operators to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 6 databases: Users (up to 10 users) Products (up to 1000 products) Weighings (up to 1000 weighings) Tares (up to 100 tares) Programs (up to 100 drying programs) Drying process reports (up to 1000 reports) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Exchange of information within the system is performed by means of USB port on bi-directional basis. It is possible to import and export databases using memory sticks. Direct access to information It is possible to access functions and databases directly, using keyboard soft keys. Database – access to databases Function – access to basic functions F1 and F2 – programmable function keys and menu navigation keys Reports – access to database of drying process reports Profile – access to parameters settings Sample – access to products database

€1,342.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]