Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
WTW
Location
Ennevelin - France
This item is
for sale
State of item
used
Categories

BOD measurement BOD meter OxiTop IS-12 with induction stirrer WTW

item image

Description from the supplier

BOD measurement BOD meter OxiTop IS-12 with induction stirrer WTW

Range: 0 to 4000 mg/l
5-day data logger
Automatic start when temperature reaches 20°C
Operating temperature (metric): 5°C to 50°C

Included:
IS 12 inductive stirring system
12 OxiTop measuring units
Universal power supply
12 sample bottles
12 rubber sleeves
12 stirring bars
container with measuring head
stirrer

Product details

DetailMade in : Germany Serial No :
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Sistema completo con VTF per AREX 6 digital PRO Velp-cover
Sistema completo con VTF per AREX 6 digital PRO Velp

The first hot plate stirrer with embedded Wi-Fi technology Wherever you are, VELP Ermes allows the r (more)eduction of routine operations thanks to the real-time control of your AREX-6 Connect PRO. Access your analyzes from PC, Pad or smartphone, to maximize the productivity and reproducibility of your reactions. Immediate notifications and alerts will allow you to always be informed and thanks to the remote interruption you will have total control of your processes. SAFETY FIRST AREX-6 Digital PRO is equipped with 2 independent temperature reading circuits that protect the instrument in the event of a malfunction of one of the two. If the probe is not inserted into the sample being analyzed, the instrument stops heating, showing a safety message on the display. AREX-6 Digital PRO is equipped with the most advanced technology and allows you to set the maximum temperature limit required for analyzes with specific temperatures. The Lock function prevents inadvertent changes to settings by locking the instrument. CerAlTop™, High Resistance The CerAlTop™ plate, made of aluminum alloy covered with a ceramic layer, guarantees a homogeneous and fast heat transfer over the entire surface. Furthermore, the thin ceramic layer protects the straightener from scratches and chemicals. CUTTING-EDGE THERMOREGULATION AREX-6 Digital PRO offers the best thermoregulation available. The PID thermoregulation system guarantees stable, fast temperature control with minimal overshoot. VTF and Pt100 probe allow accurate and precise temperature control. It is possible to choose between 2 different thermoregulation modes: - FAST: The set temperature is reached quickly. - FINE: The set temperature is reached slowly, minimizing overshoot. UNPRECEDENTED PERFORMANCE The brushless motor allows you to shake up to 20 liters at an adjustable speed from 30 to 1700 rpm. Thanks to the SpeedServo™ system, the speed is kept constant even when the viscosity varies. The Alnico magnet guarantees homogeneous agitation, even in the peripheral areas of the plate and a powerful magnetic coupling between motor and stir bar, a very important aspect when using accessories. MAXIMUM INSTRUMENT PROTECTION AREX-6 Digital PRO is an IP42 product designed to guarantee years of use and resistance in the laboratory. The structure and materials protect the internal parts of the instrument from possible damage. AREX-6 Digital PRO is guaranteed for 3 years. The silicone cover ensures further protection of the instrument from possible spills or splashes. Technical characteristics - Speed ​​regulation precision: 5 rpm. - Temperature regulation resolution: 1°C. - Connection for digital thermoregulators: VTF / VTF EVO. - Probe connection: Pt100. - Sample thermoregulation: ±0.5°C (VTF / VTF EVO) ±1°C (PT100). - Automatic reverse rotation: yes. - Probe detector: yes. - Lock function: yes. - Hot surface warning: on display. - Heating activation button: yes. NEW INTERFACE - EASY USE Bright LED display and intuitive icons. The icons will show you: probe or thermoregulator connection, heating activation, reaching the set temperature, timer activation and rotation reversal. The speed and temperature are set by the sensitive knobs, and are activated only after they are pressed. AREX-6 Digital PRO is equipped with an advanced menu that allows you to configure the instrument with the features that best suit the needs of the individual laboratory. INTEGRATED TIMER AND ROTATION REVERSE The central button allows you to set the timer from 1min to 99h59min. You can set the timer in 2 different modes: - Snap: The timer starts counting down as soon as a function is activated (stirring or heating). - SetP: The timer starts counting down as soon as the set temperature is reached. Furthermore, it is possible to set the rotation reversal at time intervals. ACCESSORIES OIL BATH AND HEATING MANTELS REPLACED WITH SPHERICAL CAPS The new Spherical Caps are the perfect solution for replacing oil baths and heating mantles. Furthermore, they adapt perfectly to both the 135 mm plate diameter and the shape of the tubes allowing a fast heat transfer from the plate to the tube. To increase protection and reduce thermal dispersion, VELP has designed the new PTFE Covers. GREATER VERSATILITY The MultiAlublock™ and the new MonoAlublock™ made of aluminium, are ideal for carrying out numerous stirring and heating analyses, reducing time and space in the laboratory. - MonoAlublock™ are the ideal solution for all those applications that require analysis in tubes of the same size. - MultiAlublock™ are modular and of different types to support various tube sizes. Thanks to their modularity, it is possible to choose the mix that best suits your needs.

€729.00 ex VAT
€867.51 incl. VAT if applicable
Italy
heating & cooling, stirrers
Radwag MA 50/1.5Y.IC.WH Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]