Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Heidolph
Location
Hampton - United States
Price
$3,387.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Heidolph Hei-FLOW Expert 120 Peristaltic Pump

$3,387.00 (ex VAT)
item image

Description from the supplier

Heidolph Hei-FLOW Expert 120 Peristaltic Pump The pump drive of the model 01 of the Hei-FLOW Expert series can be operated with either single-channel or multi-channel pump heads. The flow rates with single-channel pump heads are in the range of 0.38 — 813 ml/min; with multi-channel pump heads from 0.005 — 329 ml/min.By integrating an analog interface, it is possible to control all functions externally. In addition, an optional foot switch can be adapted to enable dosing by foot pressure. Hands thus remain free to perform other work, for example, to hold the tubing and the vessel. A speed of 5 — 120 rpm with a control accuracy of ±3.5% guarantees optimum process results.

Click Here to View Product Video

  • Power Cord
  • Operator's Guide
  • Full 3 Year Manufacturer's Warranty

Product details

Speed range5 - 120 rpm
Control accuracy motor±0.5 %
Select direction of rotationCW / CCW
Flow rates single-channel pumps0.38 – 813 ml/min
Flow rates multi-channel pumps0.005 – 329 ml/min
Flow rate accuracy (water without counter pressure)±3.5 %
Analog interfacefor speed 0 - 10 V / 4 - 20 mA direction of rotation start/stop
Protection class DIN EN 60529IP 55
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Pall Allegro 1/2" Single Use TFF System-cover
Pall Allegro 1/2" Single Use TFF System

This listing is for a Pall Allegro 1/2" Single Use TFF System.The unit is in full working condition  (more)and is ready for immediate release.This Unit is fitted with a Ismatec Flowmaster FMT 300 peristaltic pump.This unit is supplied with Trolley and containers.The Pall Allegro 1/2" Single Use TFF System is a cutting-edge solution designed specifically for tangential flow filtration (TFF) in bioprocessing applications, combining innovative single-use technology with user-friendly design. Unlike traditional TFF systems, the Allegro system incorporates new concepts that enhance ease of use and efficiency, featuring a carefully considered layout that allows full access to components from one side.Key Features:Single-Use Design: Eliminates cross-contamination and cleaning requirements, enhancing system flexibility and ensuring a sterile environment.Integrated Sensors: Equipped with single-use sensors that track key process parameters, provide notifications for out-of-spec conditions, and enable automated control for optimal processing.Easy Setup: Comes with five pre-irradiated manifold sets (feed, retentate, permeate, bio container, recovery) that are ready for installation, typically taking just 20 minutes.Automated Operation: Fully automated for monitoring and controlling critical parameters, ensuring consistent performance throughout ultrafiltration and diafiltration processes.Technical Specifications:Capacity: Features a recirculation pump with a capacity of 1,000 L/hour, designed to accommodate 0.5 - 2.5 m² cassettes running at a crossflow of 5 L/min/m².Versatile Connections: Easily connects to Allegro 2D and 3D bio containers for WFI, diafiltration buffer, and process fluid in fed batch operations.Temperature Control: Includes a heat exchange plate under the retentate bio container to manage product temperature, either cooling or heating as needed.Applications:Ideal for concentration and diafiltration of proteins, recombinant molecules, potent biological drugs, cytotoxic drugs, and vaccines, the Pall Allegro system stands out as a reliable and efficient choice for modern bioprocessing needs.Brochure- http://g-eitan.com/pdf/Biotechnology/Ultrafiltration%20-%20TFF/Single%20use%20cross%20flow%20system/SingleUseTFF.pdf

United Kingdom
peristaltic pumps, process pumps
People are watching right now:
Hoefer SE300 miniVE Integrated Vertical Protein Electrophoresis and Blotting Complete Unit-cover
Hoefer SE300 miniVE Integrated Vertical Protein Electrophoresis and Blotting Complete Unit

Hoefer SE300 miniVE Integrated Vertical Protein Electrophoresis and Blotting Complete Unit Glass Pla (more)te Size (W x H) 10 x 10.5 cm or 10 x 8 cm Maximum Power Settings 1000 V, 500 mA, 50 W Compatible Spacers 0.75 mm, 1.0 mm, 1.5 mm Features - Quick, excellent results using minimal buffer - Passive cooling produces gels with straight lanes and sharp bands - Cast your own or use precast gels from a variety of manufacturers - Transfer up to 4 gels in 45 minutes with only 300 ml buffer using optional SE302 Blot Modules - Designed for use with a wide variety of precast gels The Hoefer SE300 miniVE Integrated Vertical Protein Electrophoresis and Blotting Complete Unit is a versatile and robust system designed to deliver high-quality electrophoresis and blotting results. This compact unit allows for both protein separation and electro transfer, making it an ideal choice for labs needing efficient and reliable equipment. The SE300 miniVE features passive cooling to ensure straight lanes and sharp bands, while using minimal buffer for quick, precise outcomes. Users can cast their own gels or opt for a range of compatible precast gels from various manufacturers, adding to its flexibility. With the optional SE302 Blot Modules, this unit can transfer up to four gels in just 45 minutes using only 300 ml of buffer, enhancing both efficiency and resource conservation. The complete unit includes essential components such as a lower buffer chamber, gel modules with gaskets, glass plates, combs, T-spacers, and more. Built for durability and ease of use, the SE300 miniVE ensures that researchers can achieve consistent, high-resolution results, making it a dependable asset for any laboratory focused on protein analysis. Please note: 1.0mm T-Spacers are included with purchase. Additional T-Spacers are available for purchase separately. INCLUDED: The Hoefer SE300 miniVE Integrated Vertical Protein Electrophoresis and Blotting Complete Unit includes: - Lower Buffer Chamber (tank) - Gel Modules with Gaskets, 2 assemblies - Safety Lid with High Voltage Leads - Glass Plates, Rectangular, 10 x 10.5 cm, 3 pcs - Glass Plates, Notched, 10 x 10.5 cm, 3 pcs - Combs, 10-well, 1.0 mm thick, 2 pcs - T-Spacers, 1.0 mm thick, 4 pcs - Well-Locating Decals, 2 pcs - Wonder Wedge Plate Separation Tool - Gel Seal - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$1,260.00 ex VAT
United States
electrophoresis
Radwag MA 50/1.5Y.IC Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]