Edwards nXDS20iR Dry Scroll PumpFeatures
- Bearing shield ensures separation between process gases and bearing lubrication to ensure clean vacuum and no possibility of contamination.
- Smart motor drive means consistent performance globally, pump overload protection and remote start/stop capability.
- High flow gas ballast feature allows pumping of vapours including water vapour at up to 240 gh-1
- Simple single sided scroll design allows maintenance to be done in minutes for low cost of ownership and maximum up-time.
- Enhanced versions offer up to 20% lower peak power requirements during initial pump down.
The nXDS allows a wide range of control and communication options
The nXDS comes as standard with a manual, easy to use, gas ballast port
A perfect companion for your turbomolecular pump
With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features Edwards nXDS is the best performing pump in its class.nXDS improves on legacy XDS pumps by offering increased pumping speeds, combined with lower ultimate pressures, lower power consumption and lower noise - up to 20 times quieter than other pumps. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. nXDS pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimised pumping performance globally.
Unlike the standard nXDS20i, the Edwards nXDS20iR isdesigned for specialist applications such as gas recirculation, rare gaspumping and recovery or other applications where the dilution of the pumped gasis undesirable, or where sealing is integral to minimizing potential gas loss.
Click Here to View Product Video
INCLUDED:
The Edwards nXDS20iR Dry Scroll Pump includes:
- 1 Year Full Parts and Labor Warranty
- Power Cord
- Manufacturer's Documentation
- Operator's Manual
Edwards nXDS20iR Dry Scroll Pump Technical SpecificationsNominal rotational speed1800 rpmDisplacement28.0 m3h-1 / 16.5 ft3min-1Peak pumping speed22.0 m3h-1 / 13.0 ft3min-1Ultimate vacuum (total pressure)0.030 mbar / 0.022 TorrMinimum standby rotational speed1200 rpmSpeed control resolution (percentage of full rotation speed)1%Pumping speed at minimum rotational speed10Maximum continuous inlet pressure50 mbarMotor power 1-ph260 WPower connector 1-phIEC EN60320 C13Recommended fuse10A, 250Vac rmsWeight25.6 kg / 56 lbInlet flangeNW25Exhaust flangeNW25Noise level52 dB(A)Vibration at inlet flange< 4.5 mms-1 (rms)Leak tightness (static)< 1x10-6 mbar ls-1Operating temperature range10 to 40 °C / 41 to 104 °FElectrical Supply115/230VComparison of ModelsSpecificationEdwards nXDS6iREdwards nXDS10iREdwards nXDS15iREdwards nXDS20iRNominal rotational speed (rpm)1800180018001800Displacement (m³h⁻¹ / ft³min⁻¹)6.2 / 3.612.7 / 7.517.1 / 10.128.0 / 16.5Peak pumping speed (m³h⁻¹ / ft³min⁻¹)6.2 / 3.611.4 / 6.715.1 / 8.922.0 / 13.0Ultimate vacuum (total pressure) (mbar / Torr)0.020 / 0.0150.007 / 0.0050.007 / 0.0050.030 / 0.022Weight (kg / lb)26.2 / 5825.8 / 5725.2 / 5625.6 / 56Inlet flangeNW25NW25NW25NW25Noise level (dB(A))52525252Operating temperature range (°C / °F)10 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 104Electrical Supply115/230V115/230V115/230V115/230V.comparison-table tr td:nth-child(5) { background-color: #fffacd; }
Nominal rotational speed | 1800 rpm |
Displacement | 28.0 m3h-1 / 16.5 ft3min-1 |
Peak pumping speed | 22.0 m3h-1 / 13.0 ft3min-1 |
Ultimate vacuum (total pressure) | 0.030 mbar / 0.022 Torr |
Minimum standby rotational speed | 1200 rpm |
Speed control resolution (percentage of full rotation speed) | 1% |
Pumping speed at minimum rotational speed | 10 |
Maximum continuous inlet pressure | 50 mbar |
Motor power 1-ph | 260 W |
Power connector 1-ph | IEC EN60320 C13 |
Recommended fuse | 10A, 250Vac rms |
Weight | 25.6 kg / 56 lb |
Inlet flange | NW25 |
Exhaust flange | NW25 |
Noise level | 52 dB(A) |
Vibration at inlet flange | < 4.5 mms-1 (rms) |
Leak tightness (static) | < 1x10-6 mbar ls-1 |
Operating temperature range | 10 to 40 °C / 41 to 104 °F |
Electrical Supply | 115/230V |
QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.