Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
used
Categories

1100 Series G1330A ALS Therm Sample Chiller

Biomatyx
item image

Description by the supplier

AGILENT 1100 Series G1330A ALS Therm Sample Chiller

Available quantity : 8

Weight: 20.7 kg (45.6 lbs)

Dimensions: 140 × 345 × 435 mm (5.5 × 13.5 × 17 inches)

Line voltage 100 – 120 or 220 – 240 VAC, ± 10 % Automatic selection

Line frequency 50 or 60 Hz, ± 5 %

Power consumption Autosampler: 300 VA

ALS Thermostat: 260 VA

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Chiller Variocool VC 10000 LAUDA-cover
Chiller Variocool VC 10000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 10000 model (measured with ethanol): - a 20°C, 10.00 kW - a 10°C, 7.60 kW - a 0°C, 5.30 kW - a -10°C, 3.50 kW - a -20°C, 2.00 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€19,980.00 ex VAT
€23,776.20 incl. VAT if applicable
Italy
chillers, heating & cooling
Chiller Variocool VC 2000 LAUDA-cover
Chiller Variocool VC 2000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 2000 model (measured with ethanol): - at 20°C, 2.00 kW - at 10°C, 1.50 kW - at 0°C, 1.06 kW - at -10°C, 0.68 kW - at -20°C, 0.38 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€7,173.00 ex VAT
€8,535.87 incl. VAT if applicable
Italy
chillers, heating & cooling
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V-cover
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V

Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2 (more)900W, 120VACFeatures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA03A1P1-41AA1NCooling Capacity @ 20°C1.4 kWCooling Capacity @ 10°C0.99 kWCooling Capacity @ 0°C0.53 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range45 to 100 psi / 310 to 689 kPaMaximum Pump Flow Rate2.6 gpm / 9.8 lpmPower Requirements120V, 60Hz, 16.2AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(4) { background-color: #fffacd; }

$6,946.00 ex VAT
United States
chillers, heating & cooling
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V-cover
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V

Polyscience CA02A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VACFe (more)atures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA02A1P1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA02A1T1-41AA1NCooling Capacity @ 20°C0.85 kWCooling Capacity @ 10°C0.6 kWCooling Capacity @ 0°C0.4 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range20 to 90 psi / 138 to 689 kPaMaximum Pump Flow Rate3.5 gpm / 13.2 lpmPower Requirements120V, 60Hz, 13.7AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(3) { background-color: #fffacd; }

$6,982.00 ex VAT
United States
heating & cooling, chillers
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]