Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
Unigreenscheme
Location
Caerphilly - United Kingdom
Price
£500.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

RMC CR21, CR21 Control, Transformer & Cryochamber Lab NOTE - THIS IS A SPARES/REPAIRS ITEM

Unigreenscheme£500.00 (ex VAT)
item image

Description by the supplier

RMC CR21, CR21 Control, Transformer & Cryochamber Lab

These items were removed from a university where they were surplus to requirement.

All the units are in reasonably good cosmetic condition. However, they cannot be tested as they all require a connection to the transformer, which is not operational.Therefore, this listing is sold as Spares/Repair.

All items included are as follows:

Model1#: CR21 ControllerSerial1#: 10521389

Model2#: CR21 Transformer BoxSerial2#: 10521391

Model3#: CR21 CryochamberSerial3#: 10521390

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Chiller Variocool VC 2000 LAUDA-cover
Chiller Variocool VC 2000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 2000 model (measured with ethanol): - at 20°C, 2.00 kW - at 10°C, 1.50 kW - at 0°C, 1.06 kW - at -10°C, 0.68 kW - at -20°C, 0.38 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€7,173.00 ex VAT
€8,535.87 incl. VAT if applicable
Italy
chillers, heating & cooling
Memmert IPP260ecoplus Peltier-Cooled Forced Circulation Incubator 256L, 115V-cover
Memmert IPP260ecoplus Peltier-Cooled Forced Circulation Incubator 256L, 115V

Memmert IPP260ecoplus Peltier-Cooled Forced Circulation Incubator 256L, 115V Setting Temperature Ran (more)ge Ambient 0°C to 70°C Convection Type Peltier Fan Forced Circulation Chamber Volume 256 L (9 cu.ft.) Features - 256 L volume capacity with precise temperature control - Working temperature range from 0°C (at least 20°C below ambient) to +70°C - Energy-saving Peltier heating/cooling system with individually controlled upper and lower elements - ControlCOCKPIT with TwinDISPLAY and adaptive multifunctional digital PID-microprocessor controller - Process timing starts only when the set temperature is reached with the SetpointWAIT function - Three freely selectable temperature calibration points for accurate control - Over- and undertemperature monitor with AutoSAFETY protection for enhanced safety - Durable stainless steel interior and textured stainless steel exterior for corrosion resistance and easy cleaning The Memmert IPP260ecoplus Peltier-Cooled Forced Circulation Incubator 256L, 115V is a high-capacity, energy-efficient solution for precision temperature control in laboratory environments. With a substantial 256-liter volume and a working temperature range from 0°C (at least 20°C below ambient) to +70°C, it is ideal for handling large sample loads and diverse incubation requirements. The incubator features an advanced Peltier heating and cooling system with individually controlled upper and lower elements, ensuring even temperature distribution. Its intuitive ControlCOCKPIT, equipped with TwinDISPLAY and adaptive PID-microprocessor controller, provides effortless control over temperature and other settings, while the SetpointWAIT function enhances accuracy by initiating process timing only once the desired temperature is reached. Safety and durability are central to the IPP260ecoplus. The AutoSAFETY system includes over- and undertemperature protection with visual and acoustic alarms, automatically adjusting to the setpoint tolerance range to protect samples. The incubator’s stainless steel interior and textured exterior are designed for long-term corrosion resistance and easy maintenance. With nine adjustable shelves and a maximum chamber load capacity of 661 lbs, it supports extensive sample storage, making it a reliable and versatile addition to any laboratory focused on precision and safety.. INCLUDED: The Memmert IPP260ecoplus Peltier-Cooled Forced Circulation Incubator 256L, 115V includes: - 2 Stainless Steel Grids - Tilt Protection Wall Bracket - Calibration Certificate - Power Cord - Operator's Manual - Manufacturer's Documentation - 3 Year Manufacturer's Warranty

$12,015.00 ex VAT
United States
incubators
Radwag MA 110.5Y.NS Moisture Analyzer-cover
Radwag MA 110.5Y.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,510.00 ex VAT
Poland
moisture analysers, balances
Radwag HX5.EX-1.15.HR5 One Load Cell Platform Scale-cover
Radwag HX5.EX-1.15.HR5 One Load Cell Platform Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€4,624.00 ex VAT
Poland
scales for ex areas, platform scales
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]