Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Fryka
Supplier
Jointlab srl
Location
Milano - Italy
Price
€3,250.00 
(€3,867.50 incl. VAT*)*if applicable
This item is
for sale
State of item
new
Categories

Chiller ULK 602 FRYKA

Jointlab srl€3,250.00 
(€3,867.50 incl. VAT* )* - if applicable
item image

Description by the supplier

The ULK 602 FRYKA Circulation Chiller is an exemplar of efficient energy utilization, featuring a fan with advanced EC technology. This piece of scientific equipment maintains a pleasantly low noise level due to its meticulously engineered components, and a fan that smartly adjusts its speed according to necessity.


Ease-of-use is a vital element of the design, with the inclusion of an integrated funnel, a self-sealing hose connector equipped with a quick coupling, and a drain cock for accessibility and convenience.


What makes this particular chiller unbeatable is the high-quality components it offers. A touchscreen controller possessing a first-rate glass screen, along with digital flow and fill level indicators, ensures easy and accurate control. Manufactured by a prominent German company, this chiller is designed with a refrigeration unit that's fully hermetically sealed, air-cooled, and requires low-maintenance.


Consolidating high operational reliability, the ULK 602 FRYKA Chiller offers thermal overload protection and dry-running protection. Furthermore, its software provides easy-to-understand error messages, optical and acoustic alarm signals to ensure swift troubleshooting.


The chiller complies with the proven standard, equipped with a MOD bus interface to facilitate communication and integration.


Technical specifications include an operating range of -10°C to +40°C, ensuring precise control accuracy of +/- 0.5K. Cooling capacity is fixed at 650 watts at +20°C. The circulation pump has a flow rate of 10 liters per minute, with positive flow pressure of 0.6 bar.


It boasts compact external dimensions of 31 x 41.5 x 58 cm and weighs 35 kg, making it a manageable size for most laboratories. It requires a power supply of 230V / 50Hz and features a coolant reservoir capacity ranging from 2.0 to 4.5 liters.

Product details
Temperature °Cda -10°C a + 40°C
External dimensions mm L x P x A31 x 41,5 x 58 cm
Weight kg35
Supply230 V / 50 Hz
About Jointlab srl

Jointlab.com is a website of professionals for scientific instrumentation. With us you will have answers that others will not give you. From magnetic stirrers to laboratory pumps. From electronic scales to safety cabinets: the whole world of the laboratory in jointlab.com!

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Chiller Variocool VC 3000 LAUDA-cover
Chiller Variocool VC 3000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 3000 model (measured with ethanol): - at 20°C, 3.00 kW - at 10°C, 2.40 kW - at 0°C, 1.68 kW - at -10°C, 1.03 kW - at -20°C, 0.60 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€10,800.00 ex VAT
€12,852.00 incl. VAT if applicable
Italy
chillers, heating & cooling
Chiller Microcool MC 350 LAUDA-cover
Chiller Microcool MC 350 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Cooling power for the model Microcool MC 350 (measured with ethanol):: - at 20°C, 0.35 kW - at 10°C, 0.27 kW - at 0°C, 0.20 kW - at -10°C, 0.12 kW Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Front panel with ventilation openings 5 - Four feet 1 - Overflow connection 2 - Pump connection, outflow 3 - Pump connection, return flow 4 - Rating label 5 - Alarm output 6 - RS 232 interface 7 - Power supply 8 - Drain screw 9 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€2,882.00 ex VAT
€3,429.58 incl. VAT if applicable
Italy
laboratory modules, chillers
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V-cover
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V

Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2 (more)900W, 120VACFeatures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA03A1P1-41AA1NCooling Capacity @ 20°C1.4 kWCooling Capacity @ 10°C0.99 kWCooling Capacity @ 0°C0.53 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range45 to 100 psi / 310 to 689 kPaMaximum Pump Flow Rate2.6 gpm / 9.8 lpmPower Requirements120V, 60Hz, 16.2AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(4) { background-color: #fffacd; }

$6,946.00 ex VAT
United States
chillers, heating & cooling
Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C)-cover
Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C)

Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C) Refrigeran (more)t R-404A Temperature Range -20° to 40°C Cooling Capacity 5000W @ 20°C Features - High capacity cooling for lasers, electron microscopes, and other laboratory applications - Small footprint conserves floor space - Displays temperature and pressure or flow rate simultaneously - User-adjustable temperature, pressure, and flow rate alarms - Simple operation and low maintenance DuraChill Chillers offer powerful cooling for demanding applications and serve as a cost-effective alternative to tap water cooling systems. Equipped with a microprocessor-based controller, these chillers provide a digital temperature display (in °C or °F), one-touch set point display, and a digital pressure/flow rate display (in PSI, kPa, GPM, LPM) with easy push-button selection. The inclusion of a modulated refrigeration system enhances cooling efficiency and performance, resulting in improved temperature stability and extended compressor life. With its high-capacity cooling capability, the 3860T56A1C0D is ideal for applications involving lasers, electron microscopes, and other laboratory equipment. The system features dual displays, allowing users to conveniently monitor temperature and process pressure or flow rate simultaneously. User-adjustable alarms for temperature, pressure, and flow rate enable precise control and monitoring. Despite its powerful performance, the chiller has a small footprint that conserves floor space and facilitates seamless integration into laboratory setups.INCLUDED: The Polyscience 3860T56A1C0D Chiller 1.5HP Turbine Pump, Air-Cooled, 230V, 60Hz (-20C to 40C) includes: - Power Cord - Operator's Manual - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$12,170.00 ex VAT
United States
pumps liquid & other, chillers, heating & cooling
People are watching right now:
IKA RCT basic ETS-D5 Solution-cover
IKA RCT basic ETS-D5 Solution

RCT basic ETS-D5 Solution Speed Range 50 to 1,500 rpm Temperature Setting Range 0 - 310 °C Setting a (more)ccuracy speed 10 rpm Features - Combines RCT basic magnetic stirrer with ETS-D5 contact thermometer. - Safety circuit limits max. temp. independently of set point. - Heating function switches off if temp. limit exceeded. - Set safety temp. of heating plate remains available. - Hotplate temp. displayed on RCT. - Contact thermometer display can be placed at eye level. The RCT basic ETS-D5 Solution consists of the RCT basic magnetic stirrer and the ETS-D5 electronic contact thermometer making experiments and reactions even safer. Improved temperature controlBy combining the two devices, the internal safety circuit, which is independent of the RCT basic software, can be addressed directly by the contact thermometer. For this purpose, the maximum permissible temperature in the medium is limited independently of the set point temperature. If this value is exceeded, the heating function of the magnetic stirrer switches off via the internal safety circuit - until the device is restarted. At the same time, the stirring function is maintained to avoid boiling distortions. The set safety temperature of the heating plate also remains available. The set temperature limitation of the ETS-D5 and the safety temperature of the hotplate are OR-linked. This means that every potential error leads to the heating being switched off. In addition, the temperature of the heating plate can be set independently of the medium. In this way, you actively influence the heating times. Improved displayWith the ETS-D5, you also enhance the display of your magnetic stirrer. You can see the set and actual value of the medium temperature at a glance with a resolution of 0.1 K on the contact thermometer. The setting accuracy is also refined from 1 K to 0.1 K in this combination. The current hotplate temperature is also displayed on the RCT. Another plus: The display of the contact thermometer can be placed at eye level. This makes it directly visible where the temperature is measured and controlled. In addition to the magnetic stirrer and contact thermometer, the complete solution also includes all the necessary mounting elements.INCLUDED: The RCT basic ETS-D5 Solution includes: - H 16 V Support rod - H 44 Boss head clamp - Screw driver - ETS-D5 - PT 1000.60 Temperature sensor, stainless steel - H 38 Holding rod - RCT basic - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$1,406.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]