Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Waters
Model
Waters ELSD 2424
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€1,250.00 
(€1,487.50 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 30,00 kg

Categories

Waters 2424 ELSD Evaporative Light Scattering Detector Detektor HPLC ,defective

PROFCONTROL GmbH€1,250.00 
(€1,487.50 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: 2 Solvent cabinets 2 Capillary pumps 1 Well-plate samplers 2 Autosampler thermostat (more)s 1 Thermostatted colomn compartment 1 Diode array detector 1 Handheld control module Vacuum degasser cel is missing in the vacuum degasser Capillary pump: Settable column flow range: 0.01 – 20 µl/min Recommended column flow range: 1 – 20 µl/min Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) Optimum composition range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting Delay volume: Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Pressure range: 20 to 400 bar (5880 psi) system pressure Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. Well-plate sampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Autosampler thermostat: Temperature range: setable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient temperatures < 25 °C and humidity < 50%: – 1°C to + 4 °C at a setpoint of 4 °C Temperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%: – 1°C to + 5 °C at a setpoint of 4 °C Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. Handheld control module: The control module provides complete local control and monitoring of a single module or an entire Agilent series system. There is no data evaluation in the control module. The control module allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses.

€9,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
THALES/THOMSON YD1048 Planar Triode NEW- PRODUCED July 2003 NSN 5960-12-156-6996-cover
THALES/THOMSON YD1048 Planar Triode NEW- PRODUCED July 2003 NSN 5960-12-156-6996

one Metal Ceramic Planar Triode , NSN 5960-12-165-6996High Power, High Precision Special Purpose TYP (more)E  for Professional and MIL SPECS - Application i.e. in AIRBORNE  PULSE RADAR DEVICES Manuf.  THOMSON TUBES / THALES / EADS Model: YD 1048 manufactured 07/2003 by THOMSON TUBES ELECTRONIQUES ( FRANCE ) ; NEW and originally packed - see PHOTO the here offered tube has much higher specs and reliability than the normal on the market available YD1048s from SIEMENS or others, which are out of old stocks and have been manufactured in the 1970s the tubes are all packed in sealed TULBS with moisture protection and will be delivered in this TULBwe have > 50 units available.....see PHOTO .... please ask for special offer for larger quantities as you can see on the PHOTO of the Purchase document, the tubes were bought for a price of > 900 Euros / per unit description:  ( DATASHEET available as pdf with email, please ask if you want to get one ) metal ceramic construction ..........high power planar triode....... Forced- AIR-cooled......Oxide-cathode; Gold Plated Contactsmax. frequency > 3.5 GHzuse for RF - amplifiers, grid-or plate- pulsed oscillators, frequency- multipliers, switching of high plate voltages;high amplification factor and trans-conductance; special in frequency stability filament with indirect heating  ( Vf)........................................6.3 V....1.35 Apulsed plate voltage.................................................................8.5 kV ( cold 10 kV )average anode current............................................................. 50 mAanode dissipation...................................................................... 250 Wgrid voltage.................................................................................. - 200 Vaverage grid current.................................................................. 18 mAgrid dissipation........................................................................... 1.5 Wmaximum anode temperature................................................. 200 °Cmaximum enveloppe temperature......................................... 250 °Ctransconductance ( S ) ............................................................. 25 mA / V ( typical )amplification factor ( my)........................................................... 105 ( typical ) to 150 ( max)capacitances -  1 MHz capacitance bridge - ......................... Kg1 = 8.8 to 9.8 pF..............g1A = 1.8 to 2.1 pF...............KA = 0.037 pF The Tube is BRANDNEW Originally Packed ......  out of NEW PRODUCTION ; The LOT from which we offer, was manufactured  in July 2003;so tube will be delivered with our 2 years Warranty we have many of these tubes in our stock.... please ask for a pecial offer for larger Quantities

€167.23 ex VAT
€199.00 incl. VAT if applicable
Germany
general laboratory equipment other
Chiller ULK 1002 FRYKA-cover
Chiller ULK 1002 FRYKA

Cooling recirculator model ULK 1002 FRYKA The universal chiller for laboratory and industry, charact (more)erized by its flexibility in various applications. A great economical alternative to running water cooling systems. The 9.5-liter tank allows for wide-ranging methods of use: when full, it ensures high temperature stability over time and, at a minimum, a rapid cooling system for the most immediate needs. The new modern space-saving design, low weight, innovative technical features with low-noise cooling unit, also make it suitable for direct use at the workplace. Energy efficient: - fan with EC technology Low noise level: - particularly quiet components - the fan adjusts its speed to the required value Easy to use: - integrated funnel - self-sealing hose connector with quick coupling - drain cock High quality components: - touchscreen controller with high quality glass screen and integrated digital flow and fill level indicators - components from renowned German manufacturers - refrigeration unit: completely hermetically sealed, air cooled, low maintenance High operational reliability: - thermal overload protection - dry-running protection - optical and acoustic alarm - error messages are displayed in plain text Proven standard: - MOD bus interface Technical features: Operation from -10°C to +40°C Control accuracy +/- 0.5K Cooling capacity in watts at + 20°C 1200W; at + 10°C 850W; at -10°C 400W Circulation pump: flow rate 12 l / min Flow pressure: 2.9 bar External dimensions [LxWxH]: 35 x 44.5 x 66 cm Weight: 41 kg Ambient temperature from +12°C to +30°C Electrical connection: 230 V / 50 Hz Max current: 3.5 A Coolant tank from 2.5 to 9.5 l Fitting for 12 mm hose

€3,979.00 ex VAT
€4,735.01 incl. VAT if applicable
Italy
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]