Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Thermo
Location
Caerphilly - United Kingdom
Price
£1,400.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Thermo Separation Products/Shimadzu HPLC System - AS3000 - P1500 - RF-551 Lab

£1,400.00 (ex VAT)
item image

1 / 47

Description from the supplier

Thermo Separation Products/Shimadzu HPLC System
This was removed from a university lab where it was surplus to requirements.
It is in reasonable cosmetic condition with minor marks.
Included are;
TSP SpectraSYSTEM Variable Loop Autosampler with Column Oven & Sample CoolingModel - AS3000SN - 096/06323-5 - Powers up.
TSP Membrane DegasserSN - 103067Powers on - Solvent Leak light is lit up, though we believe this is likely because it wasn't connected up.
TSP SpectraSYSTEM P2000 Binary Isocratic PumpModel - P1500SN - 105/05727-5Powers on
Shimadzu Spectrofluorometric DetectorModel - RF-551SN - 70738Powers on
Shimadzu UV-VIS DetectorModel - SPD-10ASN - 030513Powers on

Product details

Electrical SupplyN/A
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Agilent 1100 HPLC System-cover
Agilent 1100 HPLC System

Agilent 1100 system consisting of: 1x Agilent 1100 Degasser type G1379A 2x Agilent 1100 Isocratic Pu (more)mp type G1310A 1x Agilent 1100 Variable Wavelength Detector type G1314A 1x Agilent 1100 Fluorescence Detector type G1321A 2x Solvent tray Manual injector with 1 ml sample loop Laptop Agilent 1100 IsoPump: Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min, Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar (147 psi) Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 VWD: Detection type: Double-beam photometer Light source: Deuterium lamp Wavelength range: 190–600 nm Short term noise (ASTM): ± 0.75 x 10-5 AU at 254 nm Drift: 3 x 10-4 AU/hr at 254 nm Linearity: > 2 AU (5%) upper limit Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Band width: 6.5 nm typical Flow cell: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 FLD: Detection type: Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis Light source: Xenon flash lamp Pulse frequency: 296 Hz for single signal mode, 74 Hz for spectral mode Excitation monochromator: range; 200 – 700 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 300 nm Emission monochromator: range; 280 – 900 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 400 nm Spectrum acquisition: Excitaiotn or emmision spectra, scan  speed; 28 ms per data point, step size; 1 – 20 nm Wavelength characterisric: Repeatability; ±0.2 nm, accuracy; ±3 nm Flow cell: 8 µl volume and 20 bar pressure, quartz Dimensions (HxWxD): 135 x 345 x 435 mm Weight: 11.5 kg

€13,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Radwag M1 Mass Standard - Flat Polygonal Sheet - 200 mg-cover
Radwag M1 Mass Standard - Flat Polygonal Sheet - 200 mg

Class M1 mass standards are versatile measuring tools characterized by their high precision and vers (more)atility in laboratory, industrial or commercial applications. Classified as M1 metrology class, they are valued for their versatility and accuracy in mass measurement. M1 mass standard: flat polygonal sheet Nominal value: 200 mg Material: nickel silver M1 Class Mass Standards &ndash; Key Features High-Level Precision - M1 class mass standards are designed to ensure precision in mass measurements. Permissible deviations from the actual mass are set with strict standards. Versatility of Applications - Characterized by versatility, M1-class standards are used in fields such as laboratories, industry, commerce and other areas requiring precise weight measurements. Measurement Stability - M1-class mass standards are stable over time, meaning that they maintain their measurement precision even despite prolonged use. This feature is especially important for tools that are used regularly. Operation in a Wariety of Ambient Conditions - M1 class mass standards are designed to cope with both laboratory, industrial and commercial conditions. Application 1. Analytical Laboratories In analytical laboratories where precise measurements are crucial, Class M1 mass standards are used to calibrate medium-precision balances. 2. Manufacturing Industry In the manufacturing industry, where product quality control is important, M1 class mass standards can be used to calibrate balances used in the manufacturing process. 3. Weighing Trade In the weighing trade, where measurement precision is required by law, M1 class mass standards can be used as a reference for calibrating commercial balances. 4. Testing Laboratories In research laboratories, Class M1 mass standards can be used to ensure precise weight measurements. Class M1 mass standards are versatile tools that are used in various areas of life. Their ability to adapt to different conditions makes this class of standards highly valued in the world of science, industry and commerce alike.

€10.00 ex VAT
Poland
mass standards
WATERS ALLIANCE 2695 + 2487 DAD HPLC-cover
WATERS ALLIANCE 2695 + 2487 DAD HPLC

For sale: Refurbished WATERS ALLIANCE 2695 HPLC Pricing: from EUR 9500,- till EUR 12.000,-  (please  (more)ask for official quote) Refurbished including:  2695 module  2487 Dual Absorbance Detector DAD  Software and computer Cables and connectors Also available: Other type of Detectors available like PDA Other brands of HPLC like Agilent and Thermo More refurbished parts for Waters HPLC systems All our products are fully tested and delivered with warranty   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! Waters 2695 HPLC System Specifications Number of solvents One to four Solvent conditioning Vacuum degas, two (2) operating modes, four (4) chambers, ≈<500 uL internal volume per chamber> <500uL interval volume per chamber Programmable flow rate range 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. increments Typical operating flow rate range 0.050 to 5.000 mL/min in 0.001-mL/min increments Compressibility compensation Automatic and continuous Effective system delay volume <650 µL, independent of backpressure @ 1 mL/min Plunger seal wash Integra, active, programmable Gradient profiles Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] Dry prime/wet prime Automatic, front panel control Flow ramping Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate Maximum operating pressure 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min. Pressure ripple ≤2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure) Composition accuracy ±0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm]) Composition precision ≤0.15% RSD or ≤0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) Flow precision ≤0.075% RSD or ≤0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix Flow accuracy ±1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure

Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]