Qiagen QIAsymphony SP Nucleic Acid Purification System Lab

£2,000.00 (ex VAT)
item image

1 / 91

Description from the supplier

This Qiagen QIAsymphony Nucleic Acid Purification System was removed from a university lab where it was surplus to requirements.
The system has been inspected by a service engineer who unlocked the system and ran various maintenance tasks on the robot. The various passwords will be supplied upon purchase of the system.
Qiagen QIAsymphony Nucleic Acid Purification SystemModel - QIAsymphony SPSN - 11704
Unit dimensions - L127 W73 H103cm
The item powers on and is in a good used cosmetic condition.
It comes with the following parts/consumables:-
4GB USB DongleQIAsymphony Management Console V4.0Qiagen Notebook V4 W7 32 (9023681) Restore CD (3 Discs)
Elution Microtube Rack (9020730)5 x SIC-01PC-01Waste bottle
1 x Box of 5 QX Nitrogen Cylinders (929705)8 x Boxes of Qiagen 200ul (1024) Filter Tips (990332)1 x Box QIAsymphony Installation Cartridge Kit1 x Box BGR O-Ring Tool1 x Box QIAamp DNA Blood Maxi Kit4 x Boxes 8-Rod Covers (144) (997004)1 x Box Elution Microtubes CL 24 X 96 (19588)1 x Box Reagent Cartridge Holder (997008) Box appears to have a mix of bits inside2 x Boxes 50ul (960) Filter Tips3 x Boxes 1500ul (1024) Filter Tips2 x Boxes 8-Well (336) Sample Prep Cartridges (997002)1 x Box marked as 'Odds' includes 5 x 8-Well (336) Sample Prep Cartridges, 6 x 200ul 4 x 32 Filter Tips

Product details

Electrical SupplyN/A
Last Service DateN/A
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Olympus OLA2500 Lab Automation System-cover
Olympus OLA2500 Lab Automation System

Save precious time and gain efficiency in the lab with the OLA2500 Lab Automation System (LAS), the  (more)high-throughput aliquotting solution with pre- and post-analytical sample-processing capabilities. The Olympus OLA2500 LAS is an advanced modular automation system designed for medium- to high-volume laboratories. As a front-end sample-processor the OLA2500 LAS automates sample aliquotting – saving time, labor, and eliminating sample handling errors. The system also selectively decaps and sorts tubes to any analyzer sample rack. The Olympus OLA2500 LAS is a Olympus Lab Automation solution to increase productivity and efficiency in medium- to high-volume laboratories. It automates labor-intensive tasks such as sample identification, decapping, aliquotting, out sorting, and archive preparation of sample tubes. Typical aliquotting throughput of up to 650 total tubes per hour and sorting throughput of up to 800 tubes per hour to reduce your sample preparation for better test turn-around time Minimize your staff’s biohazard exposure, reduce errors, and reduce repetitive motion injuries associated with manual sample-processing User-defined applications for aliquotting priority, sorting, decapping, and archiving. Identifies sample tube size, cap type and color, and sample volume using an on board digital image analysis system Processes most primary tubes (including conventional, BD Hemoguard or screw top closures in parallel, foil top closures with optional decapping unit) Builds personality racks for Olympus, Hitachi, Beckman-Coulter and others Automatically generate secondary tubes with user defined barcode labels No carryover with disposable, conductive aliquot tips Clot detection to ensure valid sample distribution Prioritized aliquotting when there is insufficient amount of sample in the primary tube Load up to as many as 300 samples in the input area Sort to any number of user defined sorting targets with up to 1,080 tube capacity at the destination area Holds bulk on-board consumable inventory Sort and speed primary and/or secondary samples to workstations in specific analyzer racks Access samples without interrupting the instrument with electronically controlled drawer bays Sorts primary and secondary sample tubes at high speeds to meet peak load demands Archive samples in parallel with sorting or separately in batch User defined sorting areas that accommodates any analyzer sample rack Reduces the number of “problem tubes” at the analytical workstations by sorting out the tubes with bar code label, test order and decapping problems Decap screw cap and conventional rubber closures in parallel with a standard decapper; an optional decapper handles foil top closures

€9,999.00 ex VAT
Netherlands
automated liquid handling
Thermo Scientific Matrix Hydra II Automated Liquid Handling System Lab-cover
Thermo Scientific Matrix Hydra II Automated Liquid Handling System Lab

This Thermo Scientific Matrix Hydra II Automated Liquid Handling System was removed from a universit (more)y lab where it was surplus to requirements. The system is in good cosmetic condition with marks from use. All modules power up. We had a service engineer inspect and test this system after setting up and connecting all the electronic connectors but not the pipes. The 1-channel nanofill mechanism was stuck so they took it apart and lubricated it. It's now working fine and can be controlled by the PC. The matrix stage is working fine and can be controlled by the PC but the dispenser is not working. The Hydra pump Module: They have changed the two fan guards with better ones and cleaned the fan. Now they are looking better. This module is working fine and communicates with the PC as normal. We can run test protocols but from time to time we got some error messages. I think that because the fact we have not used any liquid and the system sends feedback when the liquid passed through some parts. The system is made up of the following; 1 x Matrix Hydra IICat no. 109610 1 x Matrix 2 Position Stage 1 x Apogent Discoveries Matix Hydro Pump ModuleThe unit powers on with all 3 Fills working. 1 x Matrix P1 Control Box 1 x Innovadyne 1-Channel NanofillThe unit powers up. 1 x Grant Instruments Type MS1The unit powers up. Dell Laptop with Microsoft MouseModel - PP04XHydra II-Plus-One Control Software Version 3.1.3 InstalledThe unit powers up and the software runs. Software Discs:Matrix Hydra II-Plus-One Control Software Version 3.1.3Matrix Hydra II-Plus-One Control Software Version 3.1.2SuperLogics LE Software Suite Rev 2.92 x Socket Installation discs Various tubing and accessoriesOperating instructions

£1,255.00 ex VAT
United Kingdom
laboratory modules, automated liquid handling
People are watching right now:
Radwag MA 50.5Y.WH Moisture Analyzer-cover
Radwag MA 50.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,390.00 ex VAT
Poland