Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Agilent
Model
Agilent Technologies HP 1100
Location
Zevenhuizen - Netherlands
Price
€13,999.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Agilent 1100 HPLC System

€13,999.00 (ex VAT)
item image

Description from the supplier

The Agilent 1100 HPLC System, offered here as a meticulously maintained second-hand unit, comprises the following components:

  • **1x Agilent 1100 Degasser (Model G1379A):** Ensures efficient removal of dissolved gases in solvents for consistent, reliable chromatographic performance.
  • **2x Agilent 1100 Isocratic Pumps (Model G1310A):** Featuring a dual-piston hydraulic system with a uniquely engineered servo-controlled variable stroke drive, these pumps provide precise flow rates from 0.001 to 10 ml/min with exceptional accuracy and low pressure pulsation.
  • **1x Agilent 1100 Variable Wavelength Detector (Model G1314A):** Equipped with a double-beam photometer and a deuterium lamp, offering a wavelength range from 190 to 600 nm, with outstanding linearity and wavelength accuracy for precise absorbance measurements.
  • **1x Agilent 1100 Fluorescence Detector (Model G1321A):** A sophisticated multi-signal detector with rapid on-line scanning, capable of capturing fluorescence data within excitation and emission ranges of 200-700 nm and 280-900 nm, respectively.
  • **2x Solvent Trays**: Provided for solvent organization and system integration.
  • **Manual Injector with 1 ml Sample Loop**: Facilitates manual sample introduction with high repeatability.
  • **Laptop**: Included for instrument control and data analysis.

Agilent 1100 Isocratic Pump Specifications:

  • Hydraulic system ensures maximum reliability with a compressibility compensation feature tailored to various mobile phases.
  • Pressure capacity ranges from 0 to 40 MPa (up to 5 ml/min) and 0 to 20 MPa (up to 10 ml/min), ensuring versatility in method development.
  • Compact dimensions of 140 x 345 x 435 mm and a weight of 11 kg enhance system integration.

Agilent 1100 Variable Wavelength Detector Specifications:

  • Delivers exceptional performance with a light source of deuterium lamp ensuring low noise and drift for stable results.
  • Features a 14-µl volume flow cell capable of handling a maximum pressure of 40 bar.

Agilent 1100 Fluorescence Detector Specifications:

  • Employs a xenon flash lamp for wide-range spectral analysis with rapid data acquisition.
  • Compact design with dimensions of 135 x 345 x 435 mm, weighing 11.5 kg, complemented by an 8 µl quartz flow cell accommodating up to 20 bar pressure.

This Agilent 1100 HPLC system is structured for both reliability and productivity, offering robust functionality for diverse analytical requirements.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Waters Acquity H-Class UPLC-cover
Waters Acquity H-Class UPLC

This listing is for a Waters Acquity H-Class UPLC. The unit is in full working condition and is rea (more)dy for immediate release. Unit includes: TUV Detector Column Manager Sample Manager Binary Solvent manager Software and computer can be provided at extra cost. Unlock the full potential of your laboratory with the Waters Acquity H-Class UPLC System, a cutting-edge high-performance liquid chromatography (HPLC) solution designed for unparalleled flexibility and efficiency. This advanced system is engineered to deliver exceptional chromatographic separations, making it the ideal choice for pharmaceutical, biotechnology, food and beverage, and environmental applications. Key Features: Quaternary Solvent Blending: Seamlessly combine up to four solvents to optimize method development and enhance analytical workflows. Flow-Through-Needle Injector: Effortlessly transfer existing HPLC methods to UPLC, significantly reducing method development time and boosting throughput. Empower and MassLynx Software: Benefit from advanced data processing capabilities, including peak picking and integration, ensuring precise analysis and reporting. UNIFI Scientific Information System: Streamline data management for metabolomics, proteomics, and glycomics, facilitating comprehensive analysis. Benefits: Experience improved laboratory productivity as you transition to UPLC/UHPLC technology, reducing analysis time while increasing efficiency. Achieve enhanced resolution and sensitivity, allowing for more accurate analysis of complex samples. Simplify method development with advanced tools and software, accelerating the discovery of new methodologies. Applications: Whether you are conducting pharmaceutical research, analysing food safety, or monitoring environmental pollutants, the Waters Acquity H-Class UPLC System delivers high sensitivity and resolution for all your analytical needs. Elevate your chromatography capabilities today and transform your laboratory's performance with this innovative system.

£4,500.00 ex VAT
United Kingdom
uhplc instruments, hplc systems
Agilent 1100 HPLC System-cover
Agilent 1100 HPLC System

Agilent 1100 system consisting of: 1x Agilent 1100 Degasser type G1379A 2x Agilent 1100 Isocratic Pu (more)mp type G1310A 1x Agilent 1100 Variable Wavelength Detector type G1314A 1x Agilent 1100 Fluorescence Detector type G1321A 2x Solvent tray Manual injector with 1 ml sample loop Laptop Agilent 1100 IsoPump: Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min, Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar (147 psi) Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 VWD: Detection type: Double-beam photometer Light source: Deuterium lamp Wavelength range: 190–600 nm Short term noise (ASTM): ± 0.75 x 10-5 AU at 254 nm Drift: 3 x 10-4 AU/hr at 254 nm Linearity: > 2 AU (5%) upper limit Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Band width: 6.5 nm typical Flow cell: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 FLD: Detection type: Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis Light source: Xenon flash lamp Pulse frequency: 296 Hz for single signal mode, 74 Hz for spectral mode Excitation monochromator: range; 200 – 700 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 300 nm Emission monochromator: range; 280 – 900 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 400 nm Spectrum acquisition: Excitaiotn or emmision spectra, scan  speed; 28 ms per data point, step size; 1 – 20 nm Wavelength characterisric: Repeatability; ±0.2 nm, accuracy; ±3 nm Flow cell: 8 µl volume and 20 bar pressure, quartz Dimensions (HxWxD): 135 x 345 x 435 mm Weight: 11.5 kg

€13,999.00 ex VAT
Netherlands
hplc systems
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
IKA C 200-cover
IKA C 200

IKA C 200 Measuring range max. 40000 J Measuring time dynamic approx. 8 min Measuring time isoperibo (more)l approx. 17 min Features - Suitable for educational institutions and industrial laboratories - Manual handling for water and oxygen filling - Offers four working methods: isoperibolic, dynamic, manual, time controlled - Clear and easy-to-use display - User-friendly aftersales support - Automatic mode for ignition and gross calorific value calculation - Decomposition vessel compatible with combustible crucibles (accessory required) - Can control up to eight measuring cells with optional multiserial plug-in card (PCI 8.2) The C 200-System offers a space-saving and cost-effective solution for determining gross calorific values of liquid and solid samples. It meets rigorous validation standards and is suitable for educational institutions, industrial laboratories, and technical schools alike. With manual and automatic modes, clear display, and user-friendly software, it ensures accurate measurements and streamlined data management. Plus, its compatibility with various crucibles and optional multi-cell control capability make it a versatile choice for diverse laboratory needs.INCLUDED: The IKA C 200 includes: - C 200 - C 5010 Decomposition vessel, standard - C 248 Oxygen filling station - Ignition adapter - C 200.1 Measuring cup 2000 ml - Water emptying hose - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$22,985.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]