Agilent Series 1100 HPLC System
System contains: Solvent tray Vacuum degasser Binary pump Autosampler Thermostatted colomn compartme (more)nt Variable wavelength detector Vacuum degasser: The Agilent 1100 HPLC Degasser features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Binary pump: Flow Precision: <0.3 % RSD (typically <0.15 % RSD) Flow Range: Setpoints from 0.001 to 5.0 ml/min, in 0.001 ml/min increments Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) Pulsation: <2 % amplitude (typically <1 %) at 1 ml/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi) Compressibility compensation: User selectable, based on mobile phase compressibility Delay volume: 180 – 480 µl (600-900 µl with mixer) dependent on back pressure Recommended pH range: 1.0 – 12.5. Solvents with pH <2.3 should not contain acids which attack steel Well-plate autosampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Variable wavelength detector: Detection type: Double beam photometer Light source: Deuterium lamp Wavelength range: 190 – 600 nm Wavelength accuracy: ± 1 nm Bandwidth: 6.5 nm Linearity:> 2AU (5%) upper limit Flow cell standard: 14 µl volume, 10 mm cell path length, 40 bar
€7,999.00 ex VAT
Netherlands
hplc systems