RES Radwag Extended SI Module (PUE C32)
Supplier
Radwag
Location
Radom - Poland
Price
€298.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag RES Radwag Extended SI Module (PUE C32)

Radwag€298.00 (ex VAT)
item image

Description by the supplier

Character communication protocol is designed for communication between RADWAG balance and external device via RS232, Ethernet or Wi-Fi* interfaces.


The protocol consists of commands sent from the external device to the balance and responses sent from the balance to the device.


Responses are sent from the balance each time a command is received as a response to the command.


The commands that make up the communication protocol allow you to obtain information about the status of the balance and ways to influence its operation, for example, they allow you to receive weighing results from the balance, control the display, etc.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag MA 200/1.5Y.WH Moisture Analyzer-cover
Radwag MA 200/1.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€7,228.00 ex VAT
Poland
moisture analysers, balances
People are watching right now:
Complete system with pt100 and rod for AREX digital PRO Velp-cover
Complete system with pt100 and rod for AREX digital PRO Velp

Digital Display, Total Control of Operations AREX Digital PRO is the evolution of our best-seller, t (more)he most advanced tool available to date. By turning the left knob it is possible to adjust the temperature (up to 370°C), while with the right one you can act on the agitation (up to 1500 rpm). The SpeedServo ™ system ensures a constant speed even when the viscosity varies (counter-reaction). AREX Digital PRO offers the most advanced technology, being equipped with digital displays to set and monitor both stirring speed and temperature constantly and with absolute precision. Temperature regulation of the liquid being processed with an external probe The AREX Digital PRO package includes the external Pt100 probe, capable of reaching 250°C, with an accuracy of ±1.0°C, providing a ready-to-use system capable of directly thermoregulating the sample being processed. Previous model video: Maximum Temperature Homogeneity The particular CerAlTop™ plate, in aluminum alloy coated with a ceramic layer, ensures a formidable homogeneity of the temperature over the entire surface of the plate itself, up to 370°C and at the same time an excellent resistance to chemical agents and ease of cleaning. Maximum Protection, IP 42 AREX Digital PRO magnetic stirrers guarantee a high level of safety and protection for the user. The control panel is easily accessible, away from heat sources that are dangerous for the operator and protected from any liquid leaks by means of a special conveyor channel. AREX Digital PRO can be programmed with a maximum safety temperature, for some particular applications that require specific temperatures and in order to prevent unpleasant situations. In addition, the electronic board activates a high temperature warning ('Hot Plate Warning') which remains active even with the instrument off, when the plate temperature is above 50°C. The particular geometry prevents accidental overflows of liquid being processed from entering the internal parts of the instrument. Low Profile, Attractive Design AREX Digital PRO offers an innovative low profile and a highly attractive design for greater comfort for the user. Even the inclination of the front panel has been carefully studied to facilitate its use and make it clear that the digital displays indicating speed and temperature can be read. Greater Versatility with the new MonoAlublock™ and MultiAlublock™ The MultiAlublock™ and the new MonoAlublock™ made of aluminum are ideal for carrying out numerous agitation and heating analyzes, reducing time and space in the laboratory. - MonoAlublock™ are the ideal solution for all those applications that require analysis in tubes of the same size. - MultiAlublock™ are modular and of different types to support various tube sizes. Thanks to their modularity, you can choose the mix that best suits your needs. Technical features: Pt100 connection: provided Vertex connection: provided Counter-reaction: constant speed Electronic temperature regulation: from room temp. to 370°C Maximum safety temperature digitally settable: temperature limit can be set between 50 and 370 °C "Hot Plate Warning"  whenever the top plate temperature is over 50 °C Sample thermoregulation: ± 0.5 °C by using the Vertex thermoregulator (AREX Digital PRO); ± 1.0 °C by using Pt100 Stirring system: high-power driving magnet type ''PCM'' operated by a mono-phase motor for continuous operation

Italy
heating & cooling, stirrers