Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Thermo Scientific
Supplier
Unigreenscheme
Location
Caerphilly - United Kingdom
Price
£17,500.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

THERMO Scientific Cellomics ArrayScan VTI HCS Reader Lab

Unigreenscheme£17,500.00 (ex VAT)
item image

1 / 59
Description by the supplier

THERMO Scientific Cellomics ArrayScan VTI HCS Reader

This was removed from a university lab where it was surplus to requirements.

Everything powers up but has not been tested further at our facility.

It is in good cosmetic condition with minor marks.

Included with it are;

1x ArrayScan Vti Live Cell moduleP/N: N01-0114M/N: 06112135

1x Carl Zeiss Fc12M/N: FC12S/N: 4632000797

Thermo HCS Studio Cellomics View v6.5.1 software on disc.

Software manuals:-HCS Studio Software ClientHCS Studio - ViewCalibration Verification WizardSystem Configuration Tool

Other manuals:-Target Activation V3 BioApplication GuideLive Module User GuideRobot Plate Handler User GuideArrayScan HCS Reader Objective Installation GuideStore 1.4.2 Standard Edition New Install User GuideHCi MiddleWare Installation GuideBrightfield Module User GuideLiquid Handling Module Calibration and Testing GuidevHCS TooBox 1.6.2 Installation GuideCalibration Verification Wizard User GuideArrayScan Vti HCS Reader Administrators guide2 x User Guide AddendumLiquid Handling Module Users guideHCS Applications Server Administrators GuideApotome Module User Guide

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Radwag MA 210.5Y.IC.NS Moisture Analyzer-cover
Radwag MA 210.5Y.IC.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Hermle 2 x Microplate Swing-Out Rotor for Z287-A-cover
Hermle 2 x Microplate Swing-Out Rotor for Z287-A

Hermle 2 x microplate swing out rotor for Z287-A The Hermle 2 x microplate swing out rotor for Z287- (more)A is an essential piece of equipment for laboratories conducting experiments with microplates. This rotor can spin microplates at a maximum speed of 3,800 rpm, generating an RCF-value of 1,453 xg. With a maximum radius of 9.0 cm, it provides ample centrifugal force to ensure efficient separation of samples in a relatively short amount of time. The rotor is equipped with an efficient acceleration and deceleration system, with acceleration taking 27 seconds and deceleration taking 29 seconds. This system ensures that samples are not damaged during the spinning process and that they are collected safely at the end of the experiment. The maximum loading weight for the rotor is 100g, with a loading height of 20mm, making it suitable for use with microplates of different sizes. Overall, the Hermle 2 x microplate swing out rotor for Z287-A is a valuable addition to any laboratory conducting experiments with microplates. It is an efficient and reliable piece of equipment, capable of generating enough centrifugal force to separate samples quickly and effectively. Its efficient acceleration and deceleration system, coupled with a high maximum speed and RCF-value, make it a top choice for laboratories looking to maximize the efficiency of their experiments. INCLUDED: The Hermle 2 x microplate swing out rotor for Z287-A includes: - Operator's Manual - Manufacturer's Warranty

$1,787.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]