Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Sartorius
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€2,800.00 
(€3,332.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 30,00 kg

Categories

Sartorius MSA6202S Precision Balance Präzissionswaage Waage 6200g x 0.01g

PROFCONTROL GmbH€2,800.00 
(€3,332.00 incl. VAT* )* - if applicable
item image

Description by the supplier

Hersteller: Sartorius 


Modell: MSA6202S 


Beschreibung:


Die MSA-Anzeige- und Bedieneinheit eignet sich hervorragend zum Betrieb der Cubis Waage.e. Der Touchscreen und das hochauflösende Grafikdisplay bilden eine ideale Anzeige- und Bedieneinheit für höchste Ansprüche.Hierbei handelt es sich bei den Cubis MSA-Modellen um eine intelligente Warnfunktion, die jede Steigerung sofort erkennt.rkennt. Klare Anweisungen zur Einstellung auf dem Display helfen dem Benutzer bei der Nivellierung dDrei Standarddatenschnittstellen, Ethernet mit integrierten Webservices, USB-Schnittstelle zum PC und RS232C-Schnittstelle für Sartorius Zubeh, sorgen für eine perfekte Kommunikation.ör/Drucker. Bluetooth, neunpolige R232SC PC- und PS/2-Sc sind optionale Schnittstellen.Hnittstellen. Spannung 100 – 240 V, 50 – 60 Hz. B. ein AC-Adapter. Der eingebaute SD-Kartenleser ermöglicht es, Wägedaten, Anwenderprofile, Aufgabenkonfigurationen und Einstellungen von einer Waage auf eine andere oder einen Computer zu übertragen.


- Schwenk- und abnehmbare Anzeige- und Bedieneinheit

- Kompensiert exzentrische und außermittige Beladungsfehler

- Windschutz mit Motor

- Mit Passwortschutz

- Prüfprotokollfunktion

- GLP-konform

- Optionale motorbetriebene Nivellierfunktion

- Umrechnung von Masseneinheiten

- Zeitgesteuerte Funktionen

- Zweiter Tara-Speicher


Technische Daten:


Anschlusstyp: RS-232 25-polig / Bluetooth / RS-232 9-polig, inkl. PS

Displaytyp: Hochauflösendes Farb-TFT für kontrastreiche Darstellung

Format: Kilogramm

Ausgleichen: Unterstützt

Messzeit: ≤1 s

Modell: MSA6202S

Wiederholgenauigkeit: ≤±7 mg

Temperaturbereich (metrisch): 5 bis 40 Grad Celsius

Typ: Präzisionswaage

Breite (metrisch): 193 mm

Höhe (metrisch): 172 mm

Tiefe (metrisch): 191 mm

Elektrische Anforderungen: 100/240 V 50/60 Hz 1 A 7 w 15 VDC ±5%

Wirkleistung: 7 W

Frequenz: 50/60 Hz

Ecklast: 20 mg

Lesbarkeit: 10 mg

Luftfeuchtigkeitsbereich: 50 bis 80 % RH

Linearität: ≤±20 mg

Min. Probengewicht: 10 g

Bereich: –6200 g

Stabilisierungszeit: 1 s

Testlast: 2000 g

Abmessungen (T x B x H): 191 x 193 x 172 mm

Breite (metrisch) Schale: 206 mm

Höhe (metrisch) Kammer: 172 mm

Tiefe (metrisch) Schale: 206 mm

Spannung: 100/240 V

Stromstärke: 1 A


Das hier angebotene Gerät/System wurde getestet und ist voll funktionsfähig und einsatzbereit.

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag E1 Mass Standard - Flat Polygonal Sheet - 2 mg-cover
Radwag E1 Mass Standard - Flat Polygonal Sheet - 2 mg

E1-class mass standards are the elite in the world of metrology, because standards of this class rep (more)resent the highest level of precision and accuracy in mass measurement. The E1 classification is one of the most stringent standards that standards must meet in order to be considered the most advanced and trustworthy measurement tools. E1 - class standard: flat polygonal sheet Nominal value: 2 mg Material: aluminum What Are the Characteristics of the E1 Class? Highest Precision - The allowable deviation from the actual weight is minimal, making standards of this class ideal for applications where every gram matters. Stability and Repeatability - This guarantees a consistent level of accuracy over the long term. Accurate Calibration - Standards of this class must be regularly compared with other standards of known mass to confirm their measurement accuracy. Materials with Unique Properties - E1 class mass standards are often made of materials with exceptional physical properties, which makes them stable and resistant to changes in environmental conditions. Application 1. Analytical Laboratories In analytical laboratories where accurate measurements are crucial, E1 class mass standards are used to calibrate balances with the highest precision. 2. Pharmaceutical Industry In drug manufacturing, where even the slightest deviation from the standard affects quality, E1 class mass standards are irreplaceable. 3. Scientific Research In scientific research, especially in areas requiring the highest precision, such as physics or chemistry, E1 class mass standards are used to ensure reliable results. 4. Metrology Industry In metrology laboratories where research on E1 class mass standards alone is carried out, E1 class standards are the standard of excellence. Class E1 mass standards are not only measuring tools, but also a symbol of metrological excellence. Their use affects the quality of measurements in various areas of life because they provide precision that can be relied upon. They are a key element in the world of mass measurement, shaping standards and raising the bar for all measurement tools.

€87.00 ex VAT
Poland
mass standards
Radwag PS 2100.X2.M Precision Balance-cover
Radwag PS 2100.X2.M Precision Balance

PS X2.M is a series of advanced-class precision balances of high resolution based on RADWAG MonoBLOC (more)K technology. The innovative construction of PS X2.M balance features a new single-point weighing pan fastening, which ensures its excellent geometry and minimizes eccentricity error. The labyrinth-shape fastening guarantees excellent resistance to contamination. Weighing module RADWAG MonoBLOCK technology enables weighing loads with the readability of d=0.01 g at the maximum capacity of 10 kg. Rigid base ensures stability of the weighing system and great resistance to shocks. Internal adjustment system means precision and high measurement repeatability. Leverage of internal weight mass enables adjustment within the whole measuring range. Features: d=0.01 g readability at 10 kg max capacity great resistance to ambient conditions stability and repeatability over time RADWAG MonoBLOCK technology internal adjustment within the whole measuring range complex databases and ALIBI memory ergonomic 5” colour touchscreen touch-free operation Databases The instrument allows saving completed measurement data as complex reports and graphs. There are 7 databases: Operators (max 100 entries), Products (max 5 000 entries), Weighings (max 50 000 entries), Packaging (max 100 entries) Formulations (max 100 entries), Customers (max 1000 entries), The balance enables creating formulation reports (max 500 entries). ALIBI memory provides data protection and facilitates automatic measurement recording (max 500 000 weighing records). The memory facilitates data previewing, copying and archiving. Communication PS X2.M series is equipped with the following interfaces: 2 x RS 232, USB type A, USB type B, Ethernet and Wireless Connection. USB allows for fast transfer and copying of work results (measurements, reports, databases) to a computer or other weighing device. The balance provides possibility of remote data management.

€970.00 ex VAT
Poland
balances, precision balances
Radwag MA 50/1.5Y Moisture Analyzer-cover
Radwag MA 50/1.5Y Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
moisture analysers, balances
People are watching right now:
VACUUBRAND ME 4C NT Chemistry Diaphragm Pump-cover
VACUUBRAND ME 4C NT Chemistry Diaphragm Pump

VACUUBRAND ME 4C NT Chemistry Diaphragm Pump Ultimate Vacuum 70 mbar (52 torr) Maximum Pumping Spee (more)d 2.6 cfm at 60Hz Number of Heads/Stages 2/1 Features - Outstanding chemical resistance - High performance even at low vacuum levels - Whisper quiet - Low vibration - Long diaphragm life, maintenance-free drive system Chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors. The one-stage construction provides the advantageous combination of high pumping speed and low ultimate vacuum down to 70 mbar. All major parts in contact with pumped media are made of chemically resistant fluoroplastics. Well-proven PTFE sandwich diaphragms increase reliability and extend operating life. The NT-series features further improved performance data, higher tolerance for condensates and simplified maintenance. The ME 4C NT is also available as chemistry vacuum system ME 4C NT +2AK with inlet separator to protect the pump against particles and liquid droplets, plus outlet separator to collect condensate. One-stage chemistry-design diaphragm pumps are an excellent choice for applications with corrosive gases and vapors which do not require very deep vacuum levels. They do not consume water and therefore do not produce any contaminated waste water. Typical applications are filtration as well as concentration of solvents with low boiling points. The ME 4C NT is recommended for processes which require higher flow rates. The chemistry vacuum system ME 4C NT +2AK with inlet separator and condensate catchpot is an excellent choice for rugged applications and for collecting condensates at the exhaust of the pump.INCLUDED: The VACUUBRAND ME 4C NT Chemistry Diaphragm Pump includes: - Power Cord - Operator's Manual - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$3,492.00 ex VAT
United States
pumps liquid & other
KNF UN842.3FT.40P IP44-T Diaphragm Pump-cover
KNF UN842.3FT.40P IP44-T Diaphragm Pump

KNF UN842.3FT.40P IP44-T Diaphragm Pump Ultimate Vacuum 4 mbar (abs.) Maximum Flow Rate 34L/min (2. (more)04 m3/h) Protection Class IP44 Features - Pure transfer, evacuation and compression - Highly compatible with vapors and condensation - Chemically resistant flowpath - Suitable for highly aggressive or corrosive gases and vapors - Environmentally friendly - Maintenance-free The KNF UN842.3FT.40P IP44-T Diaphragm Pump features an integrated KNF self-drying system. Designed for a wide range of applications in laboratories, including vacuum drying of chambers (for drying or heat-treating substances and components) or steam sterilizers for sterilizing instruments, vessels, filters and textiles. The KNF UN842.3FT.40P IP44-T Diaphragm Pump can be used very universally due to its high resistance to aggressive media. The KNF self-drying system allows condensed liquid to be blown out of the pump heads at a high speed during evacuation. The drying cycle can be adjusted to the requirements of the individual process using three variables. The KNF UN842.3FT.40P IP44-T Diaphragm Pump is chemical-resistant, therefore suitable for highly aggressive or corrosive gasses and vapors. This pump is 115V. The KNF UN842.3FT.40P IP44-T Diaphragm Pump is brand new in box .INCLUDED: The KNF UN842.3FT.40P IP44-T Diaphragm Pump includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$5,197.00 ex VAT
United States
pumps liquid & other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]