Radwag MA 210.5Y.IC.NS Moisture Analyzer

€4,054.00 (ex VAT)
item image

Description from the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?

If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:

It Dries in 4 Ways

The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.

The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.

The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.

You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.

The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.

What Drying Temperature Should I Set?

The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.

The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C.

How Do I Finish the Drying? In 4 Ways

The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.

Automatic mode
You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.

Manual mode
You terminate the measurement yourself by pressing the STOP button.

Time-defined mode
The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!

User-defined mode
When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.

Digital Weighing Auditor

Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.

Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags*that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?

We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.

Full data security

Electronic signatures

Validations

Electronic records

Audit trails

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

*RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details

FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Pioneer PX6202 Ohaus-cover
Pioneer PX6202 Ohaus

AFFORDABLE PRICE AND EXCELLENT RESULTS The Pioneer PX combines basic weighing functionality with com (more)petitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education environments. The PX is affordably priced and intuitively designed for intelligent operation, with a 2-line display to provide additional information and USB and RS232 interfaces for easy communication connection. - Excellent value for money - Built to last, Pioneer is designed with a metal base frame, stainless steel underplate and weighing pan - Features of the top class as standard: second line in the display for additional information or usage tips; static removal bar for proper grounding; USB connectivity. Other Standard Features and Equipment Metal base, plastic top housing, removable stainless steel weighing pan, removable glass draft shield or side doors, real-time clock with GLP/GMP data, integrated weigh below hook, safety bracket, safety lockout for adjustment and protective hood, user selectable environmental filters and brightness settings, auto tare, auto dim, user selectable span calibration points, software lockout and reset menu, communication settings and options user selectable data printout, user definable project and user ID, software overload/underload indicator, stability indicator, operation in 11 languages. MODELS AVAILABLE InCal= internal calibration. ExCal= external calibration *CE approved models STANDARD FUNCTIONS FOR PROFESSIONAL USE - Real-Time Clock (RTC) function maintains accurate time even in the event of a power outage. The GLP/GMP data output function allows sample name, project, user and balance IDs to be recorded, helping to meet traceability and compliance requirements. Password protection reduces the risk of accidental or unauthorized changes. - Equipped with USB and RS232 connectivity ports, the Pioneer PX scale allows for easy communication with a PC, impact printer or Zebra label printer. - Eco-friendly features: Auto shut-off and other brightness settings save energy when the scale is not in use.

€1,256.00 ex VAT
€1,494.64 incl. VAT if applicable
Italy
analytical balances accessories, balances accessories
Sartorius MSA6202S Precision Balance Präzissionswaage Waage 6200g x 0.01g-cover
Sartorius MSA6202S Precision Balance Präzissionswaage Waage 6200g x 0.01g

Manufacturer: Sartorius Model: MSA6202S Description: The MSA display and control unit is ideal for o (more)perating the Cubis balance.e. The touchscreen and high-resolution graphic display form an ideal display and control unit for the highest demands.This is an intelligent warning function on the Cubis MSA models that immediately recognises any increase.r recognises any increase. Clear setting instructions on the display help the user to level the Three standard data interfaces, Ethernet with integrated web services, USB interface to the PC and RS232C interface for Sartorius accessories, ensure perfect communication. Bluetooth, nine-pin R232SC PC and PS/2-Sc are optional interfaces. Voltage 100 - 240 V, 50 - 60 Hz. B. an AC adapter. The built-in SD card reader makes it possible to transfer weighing data, user profiles, task configurations and settings from one scale to another or to a computer. - Swivelling and removable display and control unit - Compensates for eccentric and off-centre loading errors - Draft shield with motor - With password protection - Test report function - GLP-compliant - Optional motorised levelling function - Conversion of mass units - Time-controlled functions - Second tare memory Technical data: Connection type: RS-232 25-pin / Bluetooth / RS-232 9-pin, incl. PS Display type: High-resolution colour TFT for high-contrast display F

€2,800.00 ex VAT
€3,332.00 incl. VAT if applicable
Germany
precision balances, balances
Radwag E2 Mass Standard - Stainless Steel Wire -500 mg-cover
Radwag E2 Mass Standard - Stainless Steel Wire -500 mg

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed  (more)as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class standard: stainless steel wire Nominal value: 500 mg Material: stainless steel High Precision of measurements The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component. Stability over Time An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. Applications 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€59.00 ex VAT
Poland
mass standards
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]