Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
MA 210.5Y.IC Moisture Analyzer
Supplier
Radwag
Location
Radom - Poland
Price
€4,054.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag MA 210.5Y.IC Moisture Analyzer

Radwag€4,054.00 (ex VAT)
item image

Description by the supplier

Do you need a moisture analyzer that not only determines moisture or dry matter content with impressive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages?


If so, learn about the functionality of the ELLIPSIS series of moisture analyzers:


It Dries in 4 Ways


The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step.


The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.


The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.


You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.


The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.


What Drying Temperature Should I Set?


The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.


The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C.


How Do I Finish the Drying? In 4 Ways


The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.


Automatic mode

You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.


Manual mode

You terminate the measurement yourself by pressing the STOP button.


Time-defined mode

The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!


User-defined mode

When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.


Digital Weighing Auditor


Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.


10-Inch Display


Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.


Uncompromising User Verification


For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.


Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User


The light colour will tell you about status, process results, procedures, or alerts.


Hotspot


Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.


RFID


ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.


Live Note – Note Down Your Conclusions


It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.


Handy Library


This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.


Widgets


Prepared to display what you need most at any given moment.


21 CFR Part 11


Do you work in the pharmaceutical industry? Do you need a digital signature?


We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.


Full data security


Electronic signatures


Validations


Electronic records


Audit trails


Modbus TCP/IP


is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators.


A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.


* RFID ISO/IEC 14443 Type A, 13.56 MHz

Product details
FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Replaceable unit, Statistical Quality Control, ALIBI Memory, Drying modes, Samples drying, Moisture content analysis, Dry mass determination, Wi-Fi
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag E2 Mass Standard - Flat Polygonal Sheet - 100 mg-cover
Radwag E2 Mass Standard - Flat Polygonal Sheet - 100 mg

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed  (more)as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class standard: flat polygonal sheet Nominal value: 100 mg Material: Nickel silver High Precision of measurements The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component. Stability over Time An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. Applications 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€34.00 ex VAT
Poland
mass standards
Radwag WLC 60/120/C2/K Precision Balance-cover
Radwag WLC 60/120/C2/K Precision Balance

Precision of WLC balances Fast, accurate and repeatable weight determination. Energy-efficient elect (more)ronics and display, combined with an internal rechargeable battery, are the perfect duo to allow you to work without access to mains power. Precision not just in the name When we designed this balance, we took care of the smallest details – both those you can’t see, hidden in the solid housing, and those you can touch. This balance is the result of a combination of our experience and true precision. The power of steel The use of stainless steel for the pan guarantees you a long life for the balance. It is not afraid of contact with moist objects or accidental splashes. It has been with us for years, and will stay for a long time to come The LCD display has accompanied us for long years. During this time it has proven its reliability. It guarantees the readability of the result from many angles and is energy efficient. Internal power The internal rechargeable battery combined with the energy-saving display and electronics allow many hours of operation without mains power. Time counts The balance is equipped with a real-time clock that provides accurate time measurement in a way that is independent of external power supply. There is potential Printer, computer, flash drive or additional display – you can easily connect them thanks to the fact that the balance is equipped with interface RS232. You can find all accessories in our regular offer. And if you have questions about compatibility, our experts will help you. Good ALIBI The ALIBI memory used in the terminal allows for safe storage of weighing records without the possibility of unauthorized interference. A single measurement remains in the ALIBI memory up to a preset limit number of days of storage, counting from the date it was taken. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€618.00 ex VAT
Poland
precision balances, balances
Radwag MA 210.5Y.IC Moisture Analyzer-cover
Radwag MA 210.5Y.IC Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
balances, moisture analysers
People are watching right now:
AIRFLOW LCA6000VT Precision Anemometer / AIR-Velocity Meter 0.25-30 m/s +/-1%-cover
AIRFLOW LCA6000VT Precision Anemometer / AIR-Velocity Meter 0.25-30 m/s +/-1%

Hersteller: AIRFLOW Lufttechnik GmbH Modell: LCA6000 VT Luftströmungs-Messgerät..................... (more) Precision High Resolution Anemometer Beschreibung: Das LCA 6000 VT ist ein einfach zu handhabendes Messgerät für Luftströmungen mittels direkt am Messgerät angebrachten Flügelrad-Strömungssensor.Dieses Präzisions-Flügelrad sichert eine sehr hohe Auflösung bei niedrigen Luftgeschwindigkeiten ( z.B. am Arbeitsplatz ) Flügelradanemometer der Reihe LCA verfügen über eine Digitalanzeige der Strömungsgeschwindigkeit in m/s. Konstruiert für einfache Handhabung verfügt die LCA-Reihe über einen Kontrollschalter seitlich am Griff. Um das Gerät ein bzw., auszuschalten ist eine Schiebeschalter vorhanden. Spezifikationen: Geschwindigkeits-MB:   0.25 – 30 m/sec, Kalibriert < +/-1%, Messwert +/- 1 DigitGenauigk. bez. a. Umgebungsbed.: 20 °C, 1013 hPaMax. Mittelwertzeit:     AVERAGE .....12 Minuten Zulässige Umgebungsbedingungen: Barometrischer Druck:   500 mbar bis 2 bar, Temperatur ,-10 bis +50 °CLagertemperatur:    -10 bis +50 °CMaße (H/B/T):     268 x 113 x 43 mmGewicht:      (oh. Batt.) 280 gEnergieversorgung:    1x 9 V PP3 Alkaline (IEC 6F22) oder gleichwertigBatterie Nutzungsdauer:   ca. 40 h Lieferumfang: - AIRFLOW LCA 6000 VT Flügelradanemometer- Aufbewahrungsetui- Bedienungsanleitung Das LCA6000 VT ist in einem sehr guten Zustand und 100% auf Funktion geprüft

€500.00 ex VAT
€595.00 incl. VAT if applicable
Germany
general laboratory equipment other
Hermle Z327-K Refrigerated Centrifuge-cover
Hermle Z327-K Refrigerated Centrifuge

Hermle Z327-K Refrigerated Centrifuge Speed Range 200 to 18,000 RPM Maximum Capacity 4 x 200ml Tempe (more)rature Range -20°C to 40°C Features - Maintenance-free induction drive - Microprocessor with large LCD display - Motor driven lid lock - Automatic radio-frequency rotor identification system (RFID) with over speed protection, immediately upon rotor insertion - Active imbalance identification and cut-off (rotor specific) - CFC-free refrigeration system (Z327-K) - A large variety of rotors and accessories - Audible signal at the end of each run with several melody options - Noise level under 63 dBA at max. speed - Manufactured according to international safety regulations, i.e. IEC 61010 - Rotor exchange is easy to handle - Stainless steel chamber Both the Z327 and the refrigerated Z327-K offer a wide assortment of rotor options (up to 19), making them ideal for a wide variety of research applications. Rotor exchange between swing out, micro, or high-volume fixed angle rotors is very simple and can be done in a matter of seconds. The Z327-K features rear mounted refrigeration system, optimized for saving space on the lab bench at only 40 cm wide! Interested in rotors and/or adapters for this centrifuge? Let us know what size tubes you are spinning, and we can help you find the right rotor and accessories for your application. INCLUDED: The Hermle Z327-K Refrigerated Centrifuge includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 5 Year Manufacturer's Warranty

$8,570.00 ex VAT
United States
centrifuges
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]