Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
CY10.6/12.D2.K Precision Balance
Location
Radom - Poland
Price
€1,958.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag CY10.6/12.D2.K Precision Balance

€1,958.00 (ex VAT)
item image

Description from the supplier

Precision in PRO version

The CY10 series precision balance is designed for fast, accurate and repeatable weight determination. It comes with an advanced PUE CY10 terminal, and that means working comfort with a 10-inch high-resolution display with a smooth and intuitive interface.

Software for special tasks

Thanks to the terminal advanced software, the CY10 series precision balance:

Cooperates with up to 2 weighing platforms

Continuously updates all statistical data after the next measurement is entered into the balance’s memory – either globally (regardless of the weighed commodity) or separately for each weighed commodity selected from the database

Has a Tare mode expanded to include End-product issue mode capability

Works with RFID tags*(accessing personal data as well as marking specific goods or recipe ingredients in the database).

Precision balance and labelling scale in one device

If you need a labeling scale, the CY10 is the perfect solution. With a terminal that:

Cooperates with the computer program Label Editor R02

Is compatible with ZEBRA label printers

Supports single labels, bulk labels and bulk from bulk labels

Allows import/ export of label designs using a pendrive

Enables you to assign labels to goods or customers and print a global label

The CY10 series precision balance can operate as a labeling scale.

Light or dark?

Which color theme will you set on your CY10 balance? Both are user-friendly and clear, but we are curious which one you like more.

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the
5Y balances and CY10 scales
makes the devices of this series friendly to automation integrators.

A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC.
Protocol Modbus TCP/IP
in the 5Y balances and C10 scales enables, among other things, the
realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

*RFID ISO/IEC 14443 Type A, 13,56 MHz

Product details

FunctionsAutotest, Dosing, Percent Weighing, Parts counting, Peak hold, Formulation, Newton unit measurement, Statistics, Checkweighing, IR sensors, GLP Procedures, Animal weighing, Pipettes Calibration, Air density correction, Density determination, Differential weighing, Ambient conditions monitoring, Statistical Quality Control, Packaged Goods Control, ALIBI Memory, Wi-Fi
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Pioneer PX623 Ohaus-cover
Pioneer PX623 Ohaus

AFFORDABLE PRICE AND EXCELLENT RESULTS The Pioneer PX combines basic weighing functionality with com (more)petitive performance, offering high accuracy and repeatability for applications in laboratory, industrial and education environments. The PX is affordably priced and intuitively designed for intelligent operation, with a 2-line display to provide additional information and USB and RS232 interfaces for easy communication connection. - Excellent value for money - Built to last, Pioneer is designed with a metal base frame, stainless steel underplate and weighing pan - Features of the top class as standard: second line in the display for additional information or usage tips; static removal bar for proper grounding; USB connectivity. Other Standard Features and Equipment Metal base, plastic top housing, removable stainless steel weighing pan, removable glass draft shield or side doors, real-time clock with GLP/GMP data, integrated weigh below hook, safety bracket, safety lockout for adjustment and protective hood, user selectable environmental filters and brightness settings, auto tare, auto dim, user selectable span calibration points, software lockout and reset menu, communication settings and options user selectable data printout, user definable project and user ID, software overload/underload indicator, stability indicator, operation in 11 languages. MODELS AVAILABLE InCal= internal calibration. ExCal= external calibration *CE approved models STANDARD FUNCTIONS FOR PROFESSIONAL USE - Real-Time Clock (RTC) function maintains accurate time even in the event of a power outage. The GLP/GMP data output function allows sample name, project, user and balance IDs to be recorded, helping to meet traceability and compliance requirements. Password protection reduces the risk of accidental or unauthorized changes. - Equipped with USB and RS232 connectivity ports, the Pioneer PX scale allows for easy communication with a PC, impact printer or Zebra label printer. - Eco-friendly features: Auto shut-off and other brightness settings save energy when the scale is not in use.

€1,239.00 ex VAT
€1,474.41 incl. VAT if applicable
Italy
weighing terminals, balances accessories
Radwag Flat polygonal sheets, Set (1 mg - 500 mg), Wooden Box-cover
Radwag Flat polygonal sheets, Set (1 mg - 500 mg), Wooden Box

Flat polygonal sheets - set (1 mg - 500 mg) E2-class mass standards represent an exceptional standar (more)d of precision in mass measurement. Classed as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class mass standards - key features High precision measurements - Class E2 mass standards must meet stringent measurement precision standards. The permissible deviations from the actual mass are strict, making this class of standards the ideal solution for applications requiring extreme accuracy. Stability over Time - An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control - Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications - E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. The set includes: wooden box 12 mass standards 1 pair of tweezers 1 brush Material: nickel silver *The 1 mg, 2 mg and 5 mg mass standards are made of aluminum. Zastosowanie 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€503.00 ex VAT
Poland
mass standards
Radwag MA 110.5Y.WH Moisture Analyzer-cover
Radwag MA 110.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,510.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 50.X2.A Moisture Analyzer-cover
Radwag MA 50.X2.A Moisture Analyzer

MA X2.A moisture analyzers are hi-tech measuring instruments intended for quick determination of rel (more)ative moisture content, dry mass content and other parameters in samples of different substances. MA.X2.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X2.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X2 Series moisture analyzers: Automatic opening and closing of the drying chamber 5” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X2.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€1,720.00 ex VAT
Poland
balances, moisture analysers
People are watching right now:
Mortara ELI 250c Electrocardiograph ECG EKG Machine-cover
Mortara ELI 250c Electrocardiograph ECG EKG Machine

Manufacturer: Mortara Model: ELI™ 250c 12-Lead Resting Electrocardiograph REF: ELI250c-BDB-BDAAX S/N (more): 116460536977 The Mortara ELI 250c is an easy to use ECG machine that offers comprehensive functionality in a compact and lightweight form factor. This portable electrocardiograph includes a crisp, high-resolution color display that is perfect for Primary Care Physicians, Cardiologists, Family Physicians, Doctors of Osteopathy and Hospitals. With the Best 10 feature, the ELI 250c automatically selects and displays the best 10 seconds of ECG data, reducing the need for repeat ECGs. Best 10 technology helps you capture the best 10 seconds of ECG data from system memory, reducing the need for repeat ECGs. Wireless data acquisition helps increase workspace flexibility by gathering 12-lead data without the need for a tethered cable.The ELI 250c offers the innovative WAM™ wireless acquisition module or the AM12™ acquisition module. Both modules include replaceable lead wires, lead fail indicator, and a remote control with buttons for ECG acquisition and rhythm printing. With chest and limb lead reversal indicators clearly visible on the display, the clinician can easily view possible errors during ECG acquisition. Multiple connectivity options ensure patient data transfers easily from the ECG to the location of your choice. Experience the benefits of bidirectional communication via internal modem, LAN or wireless LAN with Mortara's E-Scribe™ and Athena products, as well as third-party EMR, HIS, and PACS systems via XML, PDF and DICOM®. Features: - Portable Solution: Compact and lightweight, the ELI™ 250c electrocardiograph provides comprehensive functionality, with 8.5 x 11" or A4 paper, in an easy-to-use, portable device - High-Resolution Color LCD: High-resolution color display provides real-time preview of 12-lead ECG and post-acquisition review of acquired ECG, clear visibility of waveforms, including 3, 6, 8 or 12-leads of data- High-res color display offers 12-lead ECG preview and post-acquisition review- Distinguished Mortara VERITAS™ Resting ECG Interpretation Algorithm: Widely recognized Mortara resting ECG interpretation algorithm uses gender specific and adult and pediatric criteria to provide a silent second opinion for resting ECG interpretation- Chest and limb lead reversal indicators alert clinician to possible errors- Supports pacemaker spike detection with 40,000 sps/channel data capture- Choice of Wireless or Traditional ECG Acquisition: ELI 250c offers a choice of either the innovative WAM™ wireless acquisition module or the AM12™ acquisition module. Both include replaceable lead wires, lead fail indicator, and remote control with buttons for ECG acquisition and rhythm printing- Buttons for ECG acquisition, rhythm printing & ECG transmission/order retrieval- Communication with Mortara ECG Safe™ cloud-based service- 1k sps/channel capture for signal assessment during analysis, display & printing- Comprehensive functionality in an easy-to-use, portable device- 1,000 sps per channel data capture provides more in-depth ECG signal assessment during analysis, display and printing. 40,000 sps per channel offers unsurpassed pacemaker spike detection- Best 10: ELI 250c automatically selects and displays the Best 10 seconds of ECG signal from the five minute segment of internal full disclosure, reducing clinical review time and eliminating the need for repeat ECGs- Chest and limb reversal indicators on the display assist the clinician with possible errors during ECG acquisition- Multiple options ensure patient data transfers easily to the location of your choice- Full Keyboard: Alphanumeric elastomer keyboard features dedicated "one-touch" buttons for ECG acquisition, rhythm printing, and ECG transmission/order retrieval Specifications: - Instrument Type: 12-lead electrocardiograph- Input Channels: Simultaneous acquisition of all 12 leads- Standard Leads Acquired: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6- Waveform Display: Backlit, 1/4 VGA color LCD (320 x 240); 3, 4+4, or 6+6 lead presentation- Digital Sampling Rate: 40,000 s/sec/channel used for pacemaker spike detection; 1000 s/sec/channel used for recording and analysis- Optional Functions: Mortara VERITAS resting ECG interpretation algorithm with age and gender specific criteria; connectivity with bidirectional communication- Paper: Perforated Z-fold thermal paper, A4 or 8.5 x 11” wide, 250 sheets- Thermal Printer: Computer-controlled dot array; 1 dot/ms horizontal, 8 dots/mm vertical- Thermal Printer Speeds: Computer-controlled dot array; 1 dot/ms horizontal, 8 dots/mm vertical- Gain Settings: 5, 10, or 20 mm/mV- Report Print Formats: Standard or Cabrera: 3+1, 3+3, 6, 6+6, or 12 channel- Rhythm Print Formats: 3, 6, or 12 channel with configurable lead groups- Keyboard: Elastomer keyboard with complete alphanumeric keys, soft-key menu, and dedicated function keys- Frequency Response: 0.05 to 300 Hz- Filters: High-performance baseline filter; AC interference filter 50/60 Hz; low-pass filters 40 Hz, 150 Hz, or 300 Hz- A/D Conversion: 20 bits (1.17 microvolt LSB)- Device Classification: Class I, Type CF defibrillation-proof applied parts- ECG Storage: Internal storage up to 40 ECGs; optional expanded up to 200 ECGs- Weight: 5.1 kg including battery (without paper)- Dimensions: 39.4 x 43.2 x 10.2 cm- Power Requirements: Universal AC power supply (240 VAC at 50/60 Hz) 110 VA; internal rechargeable battery Items delivered: - ECG writer unit- AMxx Series Patient Cable AM12 (REF: 9293-048-54; S/N: 116450536896)- Lead-Set, 10-Wire- Universal ECG Adapter Clips- Resting tab type electrodes (REF: 9300-033-50)- Documentation: Test and Inspection Procedure (05.2017)- User manual on CD- Power cordand some other accessoires (please see therefore pictures) Condition: The whole system is in excellent cosmetic condition, it is 100% functional tested and ready to be operated.

€1,150.00 ex VAT
€1,368.50 incl. VAT if applicable
Germany
medical supplies, ecg or ekg
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]