Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Ohaus
Supplier
Marshall Scientific
Location
Hampton - United States
Price
$1,486.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Ohaus PR5202N/E PR Series Precision Balance, 5200 g, 0.01 g

Marshall Scientific$1,486.00 (ex VAT)
item image

Description by the supplier

Ohaus PR5202N/E PR Series Precision BalanceOffering accuracy and repeatability in essential weighing applications in laboratory, industrial andeducation settings, PR Analytical and Precision Balances deliver competitive performance at aneconomical price. Featuring RS-232 connectivity for easy communication, and a backlit display and asimple interface for uncomplicated operation, the PR is perfectly designed for your workplace.

The PR is equipped with three essential weighing modes, RS-232 connectivity for datatransfer and storage, making it ideal for routine weighing applications.

Equipped with an easy-to-read, bright backlit display and a simple user interface,the PR is incredibly easy to operate, with almost no training required.

The PR’s small footprint saves desktop space while providing a large weighingsurface. The PR is durably constructed, and features a stainless steel panto withstand day-to-day use in the workplace.


Click Here to View Product Video




INCLUDED:

The Ohaus PR5202N/E PR Series Precision Balance includes:

- Power Cord

- Operator's Guide

- Manufacturer's Documentation

- 1 Year Manufacturer's Warranty

Product details
Maximum Capacity5,200 g
Readability0.01 g
Readability (Certified)0.1 g
Pan Size (Ø_Diameter)180.0 mm (7.1 in)
Internal CalibrationNot Applicable
Draftshield
Dimensions (Height)93.0 mm (3.7 in)
Working Environment50°F – 86°F, 80%RH, non-condensing
Test Weight5000g, OIML F1 or ASTM Class 3
Dimensions (Length)317.0 mm (12.5 in)
Dimensions (Width)201.0 mm (7.9 in)
In-use coverNo
Net Weight3.5 kg (7.7 lb)
Legal for TradeNTEP Certified
Tare RangeTo capacity by subtraction
Repeatability (typical)0.01 g
Linearity ±0.02 g
Pan ConstructionStainless Steel
Stabilization Time1 s
Battery LifeNot Applicable
Auxiliary Display ModelAvailable as an Accessory
Minimum Weight (USP, 0.1%, typical)20 g
Auto DoorNot Applicable
Minimum Weight8.2 g
Built-in IonizerNo
Working Environment10°C – 30°C, 80%RH, non-condensing
DisplayLCD with backlight
PowerAC Adapter (Included)
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag 5Y.60.PM Precision Balance-cover
Radwag 5Y.60.PM Precision Balance

Fast and Stable Measurement It only takes a second for the balance to display the final measurement  (more)result. Weighing Heavy Loads with High Accuracy On the large weighing pan of a PM balance, you can weigh a load of 120 kg with a readability of 0.2 g and second-to-none repeatability. Minimum Eccentricity Error Over the Entire Range PM balances can be used to determine the mass of irregularly shaped components with a centre of gravity that is significantly shifted from the weighing pan axis. Parameter Stability Over Time and After Transport The mechanical design is resistant and robust, allowing you to maintain the correct metrological parameters after transport and despite long and intensive use. Weighing Pan Dimensions Adapted to the Accuracy of the Balance Weigh with the highest readability of 0.01 g on the 200 x 185 mm weighing pan and with a readability of 0.2 g on the 500 x 400 mm weighing pan. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. - Full data security - Electronic signatures - Validations - Electronic records - Audit trails New, lmproved The new, taller and larger MONOBLOCK® enables the best repeatability and speed in its class of weighing platforms. 5Y Terminal With Terminal 5Y you get a 10-inch display, Digital Weighing Auditor, multi-step user verification, ambient light alerts, hotspot, RFID*, live note voice and text notes, voice commands for the balance and handy measurement history within the handy library widgets Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring. * RFID ISO/IEC 14443 Type A, 13,56 MHz

€5,968.00 ex VAT
Poland
balances, precision balances
Radwag MA 50.5Y Moisture Analyzer-cover
Radwag MA 50.5Y Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,390.00 ex VAT
Poland
balances, moisture analysers
Accuris W3300-300 - Compact Balance, 300 grams, readability 0.01 grams, 115V-cover
Accuris W3300-300 - Compact Balance, 300 grams, readability 0.01 grams, 115V

Accuris W3300-300 - Compact Balance, 300 grams, readability 0.01 grams, 115V Accuris Compact balance (more)s have been designed to meet the basic needs of academic and research labs requiring weight determinations in increments of 0.01g to 0.1 g. Their reliable and precise weighing technology utilizes gold-plated, ceramic capacitors to determine sample mass.Accuris Compact balances have been designed to meet the basic needs of academic and research labs requiring weight determinations in increments of 0.01g to 0.1 g. Their reliable and precise weighing technology utilizes gold-plated, ceramic capacitors to determine sample mass.The Compact line includes 6 models covering a wide range of maximum weight capacities. The lower capacity units (120g, 300g, and 500g) are readable to 0.01 g and come with a draft shield ring to prevent air currents from affecting measurements. These models feature a 4.5-inch diameter, stainless steel weigh pan. The larger capacity models (1000g, 5000g, and 10,000g) do not include the draft shield ring, come with larger weighing pans of 6.3 to 7-inch diameter, and are readable to 0.1g.All balances in the Accuris Compact line offer large, brightly lit LCD panels, and are easy to operate using the intuitive and splash-resistant control panel. Different modes allow weight to be displayed in various units: grams, ounces, carats, and simple programs can be used for piece counting and percent deviation weighing.Leveling feet are located toward the front of the balance for easy access, and a leveling bubble in the control panel is easy to see for quick and simple leveling on the lab bench. The balances can be calibrated using a calibration weight and a few keystrokes on the control panel – just select a calibration point in the calibration mode, place the calibration weight onto the weighing pan, and press the “CAL” button.Lightweight, and small in size, Accuris Compact balances will provide years of trouble-free service.INCLUDED: The Accuris W3300-300 - Compact Balance, 300 grams, readability 0.01 grams, 115V includes: - Weighing Pan - Draft Shield - Power Cord - One Year Manufacturer's Warranty

$324.00 ex VAT
United States
balances
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]