Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Ohaus
Supplier
Marshall Scientific
Location
Hampton - United States
Price
$4,296.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Ohaus EX623 Explorer Toploading Balance, 620 g, 0.001 g

Marshall Scientific$4,296.00 (ex VAT)
item image

Description by the supplier

Ohaus EX623 Explorer Toploading BalanceThe OHAUSEX623 Explorer Precision Balance with 620 gram weight capacity, has newlyoptimized linearity and repeatability specifications and enhanced vibrationfiltering for better balance stability. All Explorer models also come standardwith AutoCal automatic internal calibration. These combined enhancementsimprove accuracy, efficiency, and throughputA large colortouch-screen display, icon-driven application software that features 14 uniqueapplication modes, and an adjustable angle display make the OHAUS Explorerseries the easiest to use, most advanced balance in its class today.The base andterminal of the Explorer EX623 separate for maximum flexibility in any workarea. It also has four user-programmable touch free sensors to minimize crosscontamination and button wear.

620g Capacity

0.001g Readability

Large 5.7" full-color touchscreen display with intuitive set-up and application software

AutoCal automatic internal calibration for optimized weighing performance

14 application modes, 11 weighing units and 5 display languages for a wide variety of applications

4 programmable touchless sensors for hands-free operation

Modular display can be separated from the weighing base


Click Here to View Product Video




INCLUDED:

The Ohaus EX623 Explorer Toploading Balance includes:

- Power Cord

- Operator's Guide

- Manufacturer's Documentation

- 1 Year Manufacturer's Warranty

Product details
Maximum Capacity620 g
Readability1 mg
Pan Size5.1 in (130 mm)
Internal CalibrationAutoCal™ - Automatic
DraftshieldIncluded
Auxiliary Display ModelAvailable as an Accessory
Battery LifeNot Applicable
CommunicationRS232 (Included); USB (Included); Ethernet (Available as an Accessory)
Dimensions (HxLxW)13.8 in x 15.5 in x 9.1 in (350 mm x 393 mm x 230 mm)
DisplayFull-color 5.7 in VGA, touch screen
In-use coverIncluded
Legal for TradeNot Applicable
Linearity ±0.002 g
Minimum Weight (USP, 0.1%, typical)1.6 g
Net Weight15.2 lb (6.9 kg)
Pan ConstructionStainless Steel
PowerAC Adapter (Included)
Repeatability (typical)0.001 g
Stabilization Time1 s
Tare RangeTo capacity by subtraction
Units of MeasurementBaht; Carat; Custom; Grain; Gram; Hong Kong Tael; Kilogram; Milligram; Mesghal; Momme; Newton; Ounce; Ounce Troy; Pennyweight; Pound; Singapore Tael; Taiwan Tael; Tical; Tola
Working Environment50°F – 86°F, 85%RH, non-condensing (10°C – 30°C, 85%RH, non-condensing)
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag E2 Mass Standard - Stainless Steel Wire -20 mg-cover
Radwag E2 Mass Standard - Stainless Steel Wire -20 mg

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed  (more)as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class standard: stainless steel wire Nominal value: 20 mg Material: stainless steel High Precision of measurements The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component. Stability over Time An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. Applications 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€59.00 ex VAT
Poland
mass standards
Radwag MA 50/1.5Y.IC.NS Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 210.5Y.IC.WH Moisture Analyzer-cover
Radwag MA 210.5Y.IC.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
People are watching right now:
LAUDA Proline PB C heating thermostat-cover
LAUDA Proline PB C heating thermostat

LAUDA Proline immersion thermostat The LAUDA Proline bridge thermostats with vario flex pump are exc (more)ellent for thermostating in any tank. The PB models have a pressure / suction pump and are used in tanks of 200 mm. While the PBDs are equipped with pumps with more powerful pressure and used in tanks of 320 mm deep. Also available are a telescopic rod for tubs with a width of 310 to 550 mm, an ergonomic handle and attachments for side pumps. The LAUDA Proline bridge thermostats are available with two different control panels. The Master version (PB, PBD) is designed for all applications where the parameters are not changed very often. Models with the removable Command operating unit (PB C; PBD C) offer a graphic LCD screen for high ease of use and optimum functionality. Notable features - PowerAdapt system for optimal adaptation of the max. Heat output. without interfering with the mains power supply - Low level protection and adjustable overtemperature protection with audible alarm. Levels measured with float Accessories included Fittings for pump connection, telescopic rod Specific characteristics of the Proline PB C model - For tanks of 200 mm deep - State-of-the-art Command control panel, removable, for remote use; LCD display with the most advanced feature set in the LAUDA range - Tank volume max. 80 L - Water-cooled temperature range from 20°C to 300°C - Operating temperature range from -30°C to 300°C - Pump connectors M16 x 1 - Fitting 13 Ø

€5,236.00 ex VAT
€6,230.84 incl. VAT if applicable
Italy
thermostats
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]