Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Berthold Technologies GmbH
Supplier
Unigreenscheme
Location
Caerphilly - United Kingdom
Price
£675.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Night Owl EG&G Berthold Molecular Light Manager Lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

Unigreenscheme£675.00 (ex VAT)
item image

1 / 20
Description by the supplier

This Night Owl EG&G Berthold Molecular Light Manager was removed from a university lab where it was surplus to requirements.

The item powers on and is in a reasonably good used cosmetic condition but one of the connection ports on the back is damaged.

The UV Light works and white light can be seen powered on through the back.  There is a bag of loose parts inside.

Internal dimensions - D36.5 W52 H46cm

The lab said it wasn't working but didn't give any more details. We assume it is down to the damaged connection port.

It is sold for spares/repairs.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y-cover
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y

XA100 pipette calibration adapter enables calibration and/or verification of piston pipettes by mean (more)s of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 100 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
pipettes, microbalances accessories, microbalances, balances accessories, balances, analytical balances accessories, analytical balances, ultra microbalances, ultra & microbalances accessories, scales, pipettes calibration
People are watching right now:
Motic BA310 MET-T Trinocular  (Stroke 3 x 2 Stage)-cover
Motic BA310 MET-T Trinocular (Stroke 3 x 2 Stage)

Motic BA310 MET-T Trinocular (Stroke 3”x 2” Stage) Motic’s BA310MET series presents a powerful micro (more)scope line for incident light applications in all material sciences. Industrial quality control of opaque samples can be performed as well as teaching in educational environments of engineering and material professions, where affordability and ease of use are key demands. Extended flexibility is given by the BA310MET-T models with built-in transmitted light for transparent or compound materials. The BA310MET-H includes a more flexible focusing device, dedicated to larger samples with little limitation in size. Motic's LM Plan-Achromatic objectives with Long-Working Distance for incident light provide optimal image contrast for reflective, non-covered specimen. Together with a fully corrected tube lens an intermediate image without colored fringes is created. In all models the Epi-Illuminator offers a powerful 50W Halogen light source. The built-in field diaphragm and aperture diaphragm help to optimize image quality by reducing stray light and thus increasing contrast.INCLUDED: The Motic BA310 MET-T Trinocular (Stroke 3”x 2” Stage) includes: - 5X/0.13 (WD 20.3mm) Objective - 10X/0.25 (WD 17.5mm) Objective - 20X/0.40 (WD 8.1mm) Objective - 50X/0.55 (WD 8.4mm) Objective - Widefield N-WF10X/20mm with Diopter Adjustment - Dust Cover - Power Cord - Allen Key - Blue, Frosted, Green and Yellow Filters - Operator's Guide Motic BA310 MET-T Trinocular (Stroke 3”x 2” Stage) SpecificationsOptical systemColour Corrected Infinity Optical System (CCIS®)Observation tubeTrinocular head, Siedentopf type, 360° SwivelingInclination30° inclinedTrinocular light split100:0/20:80Interpupillary distance48-75mmDiopter adjustmentOn both eyepieces, +/- 5 diopterEyepiecesWidefield N-WF10X/20mm with diopter adjustmentIntermediate bodyEpi-illuminator quartz halogen with integrated field and aperture diaphragms and external lamphouseNosepieceReversed quintupleObjective classificationCCIS® LM Plan Achromatic, DINObjectives5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)Objective mounting threadW 4/5"x1/36" (RMS standard)Stand typeUprightStageMechanical stage, hard coated with built-in low position coaxial stage control and glass plateStage size240x140mmTravel range X&Y75x50mm (3"x2")CondenserFocusable and centerable Abbe condenser N.A. 0.85DiaphragmIris diaphragmFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentFine focus precision2μmFocusing stroke30mmUpper limit stopUpper limit stop preset but adjustableFilter holderOn top of the illuminator with fixing capIncident illuminationQuartz halogen 12V/50W with integrated field and aperture diaphragmsTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlIllumination interchangeabilityEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WIllumination featuresExternal lamp house for Epi-illuminatorTransformerEpi-illuminator external, transmitted internalPower supply100-240V (CE)Dimensions LxWxH508x240x465mmNet weight12.7kgComparison of ModelsSpecificationMotic BA310 MET BinocularMotic BA310 MET TrinocularMotic BA310 MET-H TrinocularMotic BA310 MET-H Trinocular (Erect Image)Motic BA310 MET-T Trinocular (3"x2" Stage)Motic BA310 MET-T Trinocular (6"x4" Stage)Motic BA310 MET-T Trinocular (Erect Image)Motic BA310 MET-T Trinocular (Stroke 3”x 2” Stage) (Erect Image)Observation TubeBinocular headTrinocular headTrinocular headTrinocular head (Erect Image)Trinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingTrinocular head, Siedentopf type, 360° SwivelingInterpupillary Distance48-75mm48-75mm55-75mm55-75mm48-75mm48-75mm48-75mm48-75mmObjective ClassificationCCIS® EC Plan Achromatic, DINCCIS® EC Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® LM Plan Achromatic, DINCCIS® EC Plan Achromatic, DINCCIS® LM Plan Achromatic, DINObjectives5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 11.5mm), 10X/0.3 (WD 6.8mm), 20X/0.40 (WD 11.1mm), 50X/0.55 (WD 8.2mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)5X/0.13 (WD 20.3mm), 10X/0.25 (WD 17.5mm), 20X/0.40 (WD 8.1mm), 50X/0.55 (WD 8.4mm)StageMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with coaxial stage controlMechanical stage, hard coated with built-in low position coaxial stage control and glass plateMechanical stage, hard coated with built-in low position coaxial stage control and glass plateMechanical stage, hard coated with built-in low position coaxial stage controlMechanical stage, hard coated with built-in low position coaxial stage control and glass plateStage Size180x140mm180x140mm180x140mm180x140mm240x140mm300x180mm180x140mm240x140mmTravel Range X&Y75x50mm75x50mm100x80mm100x80mm75x50mm150x100mm75x50mm75x50mmIllumination InterchangeabilityQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WQuartz halogen 12V/50W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3WQuartz halogen 12V/50W or LED 3WEpi-illuminator Quartz halogen 12V/50W or LED 3W, transmitted Quartz halogen 6V/30W or LED 3W.comparison-table tr td:nth-child(6) { background-color: #fffacd; }DownloadsTechnical Specification Download Operator's Manual Download

$3,970.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]