Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Fisher Scientific
Model
Fisher Scientific Isotemp
Location
Caerphilly - United Kingdom
Price
£1,010.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Fisher Scientific Isotemp No. 3016S Recirculating Water Chiller and Heating Unit

£1,010.00 (ex VAT)
item image

Description from the supplier

  • Temperature range -20 to +150˚C
  • Reservoir volume 6 litres
  • Pumping capacity 12 litres per minute

Product details

Electrical Supply1-Phase
PAT Test ResultPass
PAT Test Date19-11-2024
Voltage240V
Plug Included? (1-Phase)Yes - Standard UK 3-Pin Mains Plug (BS 1363)
Year of Manufacturen/a
Part / Catalogue Number213106181302
Last Service Dateunknown
Minimum Temperature (ºC)-20
Maximum Temperature (°C)150.0
Pump mechanism working properly?Yes
Fan Working Correctly?Yes
Pressure within expected range?N/A
Unit drained and inspected for algae or particulateYes
Air Filters CleanedNo
Fluid Filters CleanedNo
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Chiller Variocool VC 2000 LAUDA-cover
Chiller Variocool VC 2000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 2000 model (measured with ethanol): - at 20°C, 2.00 kW - at 10°C, 1.50 kW - at 0°C, 1.06 kW - at -10°C, 0.68 kW - at -20°C, 0.38 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€7,507.00 ex VAT
€8,933.33 incl. VAT if applicable
Italy
chillers, heating & cooling
Polyscience CA05A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 1740W; 120V-cover
Polyscience CA05A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 1740W; 120V

Polyscience CA05A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VACFe (more)atures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA05A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VAC is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA05A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VAC SpecificationsPart NumberCA05A1T1-41AA1NCooling Capacity @ 20°C1.74 kWCooling Capacity @ 10°C1.29 kWCooling Capacity @ 0°C0.77 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range20 to 90 psi / 138 to 689 kPaMaximum Pump Flow Rate3.5 gpm / 13.2 lpmPower Requirements120V, 60Hz, 17.4AShipping Weight172 lbs / 78.1 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(7) { background-color: #fffacd; }

$7,841.00 ex VAT
United States
chillers, heating & cooling
People are watching right now:
Radwag MA 210.5Y.NS Moisture Analyzer-cover
Radwag MA 210.5Y.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
moisture analysers, balances
WATERS ALLIANCE 2695 + 2487 DAD HPLC-cover
WATERS ALLIANCE 2695 + 2487 DAD HPLC

For sale: Refurbished WATERS ALLIANCE 2695 HPLC Pricing: from EUR 9500,- till EUR 12.000,-  (please  (more)ask for official quote) Refurbished including:  2695 module  2487 Dual Absorbance Detector DAD  Software and computer Cables and connectors Also available: Other type of Detectors available like PDA Other brands of HPLC like Agilent and Thermo More refurbished parts for Waters HPLC systems All our products are fully tested and delivered with warranty   We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty! Waters 2695 HPLC System Specifications Number of solvents One to four Solvent conditioning Vacuum degas, two (2) operating modes, four (4) chambers, ≈<500 uL internal volume per chamber> <500uL interval volume per chamber Programmable flow rate range 0.000 and 0.010 to 10.000 mL/min in 0.001-mL/min. increments Typical operating flow rate range 0.050 to 5.000 mL/min in 0.001-mL/min increments Compressibility compensation Automatic and continuous Effective system delay volume <650 µL, independent of backpressure @ 1 mL/min Plunger seal wash Integra, active, programmable Gradient profiles Eleven (11) gradient curves [including linear, step (2 curves), concave (4 curves), and convex (4 curves)] Dry prime/wet prime Automatic, front panel control Flow ramping Time (0.01 to 30.00 min in 0.01-min increments) to reach maximum flow rate Maximum operating pressure 5000 psi (345 bar) (0.010 to 3.000 mL/min) Programmable upper and lower limits. Pressure fall-off at >3.000 mL/min. Pressure ripple ≤2.5% (1 mL/min, degassed methanol, at 1700 psi backpressure) Composition accuracy ±0.5% absolute, independent of backpressure (Proportioning Valve Pair Test [degassed methanol:methanol/propylparaben, 2 mL/min, 254 nm]) Composition precision ≤0.15% RSD or ≤0.02 min SD, whichever is greater, based on retention time. (Degassed methanol:water 60:40 Dial-a-Mix, 1 mL/min, six replicates, phenone mix, 254 nm.) Flow precision ≤0.075% RSD or ≤0.02 min SD, based on retention time (N = 6) or volumetric measures (0.200 to 5.000 mL/min), isocratic premix Flow accuracy ±1% or 10 µL/min, whichever is greater, (0.200 to 5.000 mL/ min), degassed methanol, at 600 psi backpressure

Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]