Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
not_applicable
Categories

Stainless steel trolley 2 trays - ext. dim. L x W x H (mm): 850 X 540 X 940

Biomatyx
item image

Description by the supplier

Chariot inox 2 plateaux - dim. ext. L x l x h (mm) : 850 X 540 X 940

4 roues pivotantes anti-bruit ø 100 mm, dont 2 à frein

4 butoirs d'angle

Capacité de charge : 60 kg/chariot et 30 kg/étagère

Equipement Neuf, encore emballé

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
MARSHALL Select MS-RO70-T LCD Rotisserie Tube Rotator, 10-70 RPM-cover
MARSHALL Select MS-RO70-T LCD Rotisserie Tube Rotator, 10-70 RPM

MARSHALL Select MS-RO70-T LCD Rotisserie Tube Rotator, 10-70 RPM Speed Range 10 to 70 RPM Timing Ran (more)ge 1 to 1,119 Minutes Operation Modes Continuous or Timing Features - Offers precise control with a speed range of 10 to 70 RPM - LCD Display clearly shows speed and time settings for easy monitoring - Features high-quality stainless steel and oxidation-coated tube holders for longevity and corrosion resistance - Accommodates tubes of 1.5ml, 15ml, and 50ml guaranteeing research versatility - Optimizes laboratory space while providing efficient mixing capabilities - Equipped with over-speed detection and protection to ensure safe operation The MARSHALL Select MS-RO70-T LCD Rotisserie Tube Rotator is a versatile and efficient tool designed for various laboratory applications requiring gentle yet thorough mixing. With an adjustable speed range of 10 to 70 RPM, this rotator ensures precise control over mixing processes, suitable for a wide array of samples. The LCD display provides clear indications of speed and time settings, allowing for easy monitoring and adjustments. Built with high-quality stainless steel and oxidation-coated tube holders, the MS-RO70-T is durable and resistant to corrosion, ensuring long-lasting performance in demanding lab environments. This tube rotator is equipped with three selectable clip sizes to accommodate tubes of 1.5ml, 15ml, and 50ml, making it highly adaptable for different experimental needs. The DC motor guarantees reliable and smooth operation, while the option for continuous or timed operation (up to 1199 minutes) provides flexibility for various protocols. With a compact design that optimizes lab space, and a power consumption of only 40W, the MS-RO70-T is both efficient and space-saving. INCLUDED: The MARSHALL Select MS-RO70-T LCD Rotisserie Tube Rotator, 10-70 RPM includes: - 1pc Tube holder - 1 bag SS clip - Power Cord - Operator's Guide - Manufacturer's Documentation - 1 Year Manufacturer's Warranty

$854.00 ex VAT
United States
laboratory supplies other, general laboratory equipment other
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y-cover
Radwag XA17 - Adapter for Pipettes calibration 17 ml XA 5Y

XA17 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 17 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

Poland
scales, ultra & microbalances accessories, ultra microbalances, analytical balances, analytical balances accessories, balances, balances accessories, microbalances, microbalances accessories, pipettes, pipettes calibration
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]