Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
major science
Supplier
Biomatyx
Location
Ennevelin - France
This item is
for sale
State of item
not_applicable
Categories

Mini horizontal tank pink MJ-105-R Major Science

Biomatyx
item image

Description by the supplier

Mini horizontal tank pink MJ-105-R Major Science

New equipment in its original packaging

For electrophoresis

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Waters 2487 Dual Absorbance Detector-cover
Waters 2487 Dual Absorbance Detector

The Waters 2487 Dual Absorbance Detector is a two-channel, tunable, ultraviolet/visible detector des (more)igned for high-performance liquid chromatography applications. The detector uses newly designed optics with an enhanced illumination system for improved performance. These design features increase the optical throughput and sensitivity, and reduce bandwidth. This results in an overall increase in signal-to-noise ratio and improved linearity. The Waters 2487 Dual λ Absorbance Detector has the following capabilities: Stand-alone programmability – Stores up to 10 user-defined programs (or methods) consisting of up to 16 programmable timed events and 2 threshold events each. Single or dual wavelength – Monitors absorbance at one or two discrete wavelengths. Wavelength verification reference – Ensures wavelength accuracy. Automatic second order filter – Automatically engaged for wavelengths 370 nm and greater and removed for wavelengths 369 nm or less. Spectrum scan and storage – Supports spectrum scan, display, subtraction, storage, and playback, in addition to standard tunable absorbance and UV/Vis functionality. Cuvette qualification – Facilitates qualification of the detector by insertion of a standard in a cuvette without breaking any fluidic connections. This feature also allows you to use the 2487 Detector as a benchtop spectrophotometer. Cuvette sample analysis – Allows the spectrum of any sample placed in the cuvette to be recorded. Method editing and storage – Supports basic method programming, storage, and retrieval from the front panel. Full diagnostic capability – Supports built-in diagnostic tools to optimize functionality and performance. Backward compatibility – Operates as a 486 Detector with PowerLine, Millennium32 software versions lower than 3.0, and other Waters products connected via the LAC/E interface using the IEEE-488 bus. Two contact closure outputs – The 2487 Detector has two configurable switches, each of which can accommodate a maximum of +30 Vdc, 1.2 A current carry, and 0.5 A current switching. The switches (SW1 and SW2) can trigger fraction collectors and other external devices, as well as activate based on time, absorbance threshold, or ratio criteria. Wavelength range: 190 to 700 nm Bandwidth: 5 nm Wavelength accuracy: +1 nm Wavelength repeatability: +0.10 nm Noise, single wavelength: < +0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant Noise, dual wavelength: < +2.5 x 10-5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant Linearity: 5% at 2.5 AU, propyl paraben, 257 nm Drift: 1.0 x 10-4 AU/hour/° C at 254 nm (after 1 hour warmup) Sensitivity setting range: 0.0001 to 4.0000 AUFS Filter setting range: – Single wavelength: 0.1 to 5.0 seconds, Hamming (default), 1 to 99 seconds, RC – Dual wavelength: 1 to 50 seconds, Hamming (default), 1 to 99 seconds, RC Lamp source: Deuterium arc lamp Path length: 10 mm (standard analytical) Cell volume: 10 µL (standard analytical)

€1,449.00 ex VAT
Netherlands
general laboratory equipment other
People are watching right now:
Leica DMi6000B CS TCS SP5 Inverted Confocal Microscope Win10 LAS AF 273 License *Serviced*-cover
Leica DMi6000B CS TCS SP5 Inverted Confocal Microscope Win10 LAS AF 273 License *Serviced*

Manufacturer: Leica Microsystems Model: DMi6000B CS + TCS SP5 Confocal Microscope System Laser: HeNe (more) (543nm, 594nm, 633nm) /  Argon (458nm, 476nm, 488nm, 496nm, 514nm) / Diode UV 405nm Status: The extensive equipped system is completely reinstalled on a brand new computer with WIN10 and Leica LAS AF273, reinitialized and tested by Leica Service Engineer with Service report and Maintenance Batch on the device. The System is fully functional tested and ready to deliver good performance. System Description:Confocal microscope system with a broad range of scan speeds suited for high-resolution morphological imaging, as well as multispectral imaging. - 350-900 nm spectral detection range with 5 nm spectral resolution and sub-micron spatial resolution- Suitable for most fluorophores from DAPI to Cy5- Measuring up to five dimensions, including x, y, z, time and spectrum- Capable of multi-dimensional fluorescence qualitative and quantitative measurement, FRET, FRAP, FLIP, FLAP and other photobleaching-related applications- Suitable for imaging fixed specimen (No environmental chamber).Internal Detectors - Spectral detection channels: PMT1, PMT2, PMT3- Brightfield transmission channel: PMT TransMulti-dimension capability: xyz, xzy, xt, xyt, xzt, xyzt, xy, xz, xyt, xyz Stage:- Manual moving X, Y stage- Motorized z stage (piezo-controlled) with 166.68 µm scanning rangeZoom range: 1x-32x Pinhole size: 20 µm-600 µm Contrast enhancement options: Brightfield, DIC and polarized Software: Leica LAS AF, Version 2.7.3 on Windows 10, for image acquisition and processing Scanners Conventional scanner: 10-1400 Hz (2-3 frames/sec at 512 x 512 pixels) Internal detectors Reflection/fluorescence mode (spectral detection range 400-800 nm) - Spectral detection channels: PMT1, PMT2, PMT3- Additional PMT in transmission modeType         Wavelenght (nm)                      Dyes and useUV            405                                                DAPI, HoechstArgon       458, 476, 488, 496, 514              CyanFP, GFP, Alexa488, CY2, YFPHeNe        543                                               Alexa 546, Alexa 555HeNe        594HeNe        633                                               Cy5, Alexa 647 - An acousto-optical tunable filter (AOTF) controls the intensity of the visible excitation laser light.- An acousto-optical beam splitter (AOBS) is used to split excitation light and emission light instead of filter blocks.MicroscopeLeica DMI 6000B CS Trino inverted microscope with motorized XYZ-stage Objectives:- HCX PL FL L 40x/0.60 CORR PH2 0-2/C (- HCX PL APO 63x/1.40-0.60 Oil. Lbd. BL- HC PL FLUOTAR 10x/0.30 Ph1- HCX PL APO 40x/1.25 Oil Ph3 CS- HCX PL FL L 63x/0.70. CORR- HI PLAN 20x/20X/0.40 Fluorescent SourceLeica Lamphouse 106z HG 100W light source with LEJ EBQ100 Mercury Burner Power Supply for fluorescence excitation. Fluorescence Filters:- A4- L5- Y5- N2.1- Analyzer Condition:The extensive equipped system is completely reinstalled on a brand new computer with WIN10 and Leica LAS AF273, reinitialized and tested by Leica Service Engineer with Service report and Maintenance Batch on the device. The System is fully functional tested and ready to deliver good performance. Complete German Configuration Summary: 156504116            SuperZ Galvo Tisch Typ H156504114            Einsatz rot Typ H          156504145            3 Plattenkreuztisch mot SP5 invers15500325              Vorschaltgerät ebq 100 iso-l15000906000001 PMT-Modul wassergekühlt SP5/SP8155934681            Optical Outfit DMI 6000 CS w. ICT11506239              HI PLAN 20x/20X/0.40 15506203              HCX PL FL L 40x/0.60 CORR PH2 0-2/C15506192              HCX PL APO 63x/1.40-0.60 Oil. Lbd. BL15506507              HC PL FLUOTAR 10x/0.30 Ph115506181              HCX PL APO 40x/1.25 Oil Ph3 CS15506216              HCX PL FL L 63x/0.70. CORR15521505              Lichtringset f. Kondensor S23/S28156501100            Basismodul AOBS 156504750            Bedienkonsole programmierbar mit LCDs156501120            konventionelles Scanningsystem SP5 II156504500            X1 Port Emission Access156502123            Imaging Laser ROGB für AOBS156501201            Laser Port UV/405nm156502300            Imaging Laser 405nm cw 50mW156502352            AOTF UV/405156502379            UV Optik 09156504201            BF Detektor für DMI156503122            Workstation Plus 2x LCD15522023              Scanningtisch 15500138              HF-Höchstdruck-Lampe 12V 100W 156501330            SP Kanal 03156501390            Konfokal Detektor IMG15541537              C-Mount Adapter HC 0.63X15513874              Filtersystem A415513880              Filtersystem L515513888              Filtersystem Y5                                Filter N2.1                                Analyzer155933630            DMI 6000 BP CS Trino156504100            SuperZ Galvo Tisch invers15504111              Fl-Lamp Holder for DMI, straight

€50,000.00 ex VAT
€59,500.00 incl. VAT if applicable
Germany
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]