Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Fryka
Supplier
LabMakelaar Benelux B.V.
Location
Zevenhuizen - Netherlands
Price
€1,475.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Fryka MULTIstar Circulating Water Chiller

LabMakelaar Benelux B.V.€1,475.00 (ex VAT)
item image

Description by the supplier

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Chiller Variocool VC 10000 LAUDA-cover
Chiller Variocool VC 10000 LAUDA

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 10000 model (measured with ethanol): - a 20°C, 10.00 kW - a 10°C, 7.60 kW - a 0°C, 5.30 kW - a -10°C, 3.50 kW - a -20°C, 2.00 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€19,980.00 ex VAT
€23,776.20 incl. VAT if applicable
Italy
chillers, heating & cooling
Chiller Microcool MC 1200 LAUDA-cover
Chiller Microcool MC 1200 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models MC 600 and MC 1200 with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor or under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Pressure gage 5 - Front panel with ventilation openings 6 - Four casters with locking brake 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Overflow connection 5 - Rating label 6 - RS 232 interface 7 - Alarm output 8 - Power supply 9 - Drain screw 10 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€4,012.00 ex VAT
€4,774.28 incl. VAT if applicable
Italy
laboratory modules, chillers
Chiller Microcool MC 350 LAUDA-cover
Chiller Microcool MC 350 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Cooling power for the model Microcool MC 350 (measured with ethanol):: - at 20°C, 0.35 kW - at 10°C, 0.27 kW - at 0°C, 0.20 kW - at -10°C, 0.12 kW Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Front panel with ventilation openings 5 - Four feet 1 - Overflow connection 2 - Pump connection, outflow 3 - Pump connection, return flow 4 - Rating label 5 - Alarm output 6 - RS 232 interface 7 - Power supply 8 - Drain screw 9 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€2,882.00 ex VAT
€3,429.58 incl. VAT if applicable
Italy
chillers, laboratory modules
Polyscience CA05A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1740W; 120V-cover
Polyscience CA05A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1740W; 120V

Polyscience CA05A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 1740W, 1 (more)20VACFeatures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA05A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1740W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA05A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 1740W, 120VAC SpecificationsPart NumberCA05A1P1-41AA1NCooling Capacity @ 20°C1.74 kWCooling Capacity @ 10°C1.29 kWCooling Capacity @ 0°C0.77 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range45 to 100 psi / 310 to 689 kPaMaximum Pump Flow Rate2.6 gpm / 9.8 lpmPower Requirements120V, 60Hz, 17.3AShipping Weight172 lbs / 78.1 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(6) { background-color: #fffacd; }

$7,381.00 ex VAT
United States
heating & cooling, chillers
People are watching right now:
Radwag HX5.EX-1.4P.600.C 4 Pallet Scale-cover
Radwag HX5.EX-1.4P.600.C 4 Pallet Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€4,884.00 ex VAT
Poland
pallet scales, scales for ex areas
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]