Fisher Scientific Isotemp Recirculating Chiller Lab Spares/Repairs NOTE - THIS IS A SPARES/REPAIRS ITEM

£500.00 (ex VAT)
item image

Description from the supplier

Fisher Scientific Isotemp Recirculating Chiller
This was removed from a university lab where it was surplus to requirements.
The unit powers up but the lab confirmed it was not pumping correctly, and therefore not cooling correctly prior to collection.
It is sold for spares/repairs.

Product details

Minimum Temperature (ºC)-10
Maximum Temperature (°C)30.0
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Lauda Chiller LOOP 250-cover
Lauda Chiller LOOP 250

LAUDA LOOP: Compact circulation thermostat for constant temperature applications from 4° to 80°C Ove (more)r a two-year period of intensive research and development, LAUDA has reinvented Peltier technology. Based on this proven technology, LAUDA LOOP, a new type of unrivaled thermoelectric circulation thermostat, has been developed. The positive response from industry customers confirms that the design of a location-independent, space-saving and environmentally friendly temperature control meets the growing demands of modern work processes in terms of flexibility, independence and versatility. A practical, lightweight tool with a smart design for all types of applications. The two versions: LOOP 100 and LOOP 250 The two types of air-cooled devices, L 100 and L 250, provide cooling capacities of 120 and 250 Watts and a heating power of 0.2 and 0.4 Kw. The focus is on applications that require a constant temperature with low energy consumption. Both types of devices are exceptionally efficient in part load operation. Notable features - Small size, low weight - Thermostating with temperature control without refrigerants thanks to Peltier technology - Electrically adjustable fan - Exceptionally energy efficient in part load operation - 3 button control with OLED display - Voltage: 100-240V, 50 / 60Hz - RS 232 interface as standard - Very quiet and barely perceptible vibrations - Under / over temperature alarms Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections. Simple control panel with large TFT display with extensive information; easy to navigate and change settings. Tank cover elegantly hidden and protected in the structure of the instrument. Serial connection on the back: RS232; pump outlet and inlet connections. Chart of the LOOP LAUDA pump characteristics and the two LOOP LAUDA models available. DO YOU NEED HELP? Do not hesitate to contact us, our LAUDA product expert will help you choose the model that best suits your needs or design the perfect set for your laboratory. CONTACT US ➞

€3,462.00 ex VAT
€4,119.78 incl. VAT if applicable
Italy
chillers, laboratory modules
Chiller LAUDA Variocool VC 7000-cover
Chiller LAUDA Variocool VC 7000

LAUDA Variocool: Versatile circulation chillers from 1200W to 10 kW used between -20°C and +80°C to  (more)dissipate process heat in laboratories, small plants or production. LAUDA Variocool circulation chillers convince with their space-saving design and the versatility offered by a wide variety of options. They are circulation thermostats suitable for use with non-flammable heat transfer liquids within a moderate temperature range. The new control panel design and color TFT display make making changes very simple and intuitive. Various options in power kW, pump pressure / flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. All models (except VC 600) are available in the air-cooled or water-cooled (W) versions and equipped with fixed swivel castors. High performance circulation chillers starting with the VC 5000 are available with sound insulation or outdoor installation option. Cooling performance of the Variocool VC 7000 model (measured with ethanol): - a 20°C, 7.00 kW - a 10°C, 5.30 kW - a 0°C, 3.70 kW - a -10°C, 2.40 kW - a -20°C, 1.50 kW Notable features - Adjustable bypass for pressure limitation - Top filling opening, drain cock on the back - Integrated programmer with 150 segments, divisible into 5 programs - Electronic level indicator with low level alarm - SmartCool system for energy-saving digital control of cooling, including automatic compressor control - Temperature graphs on display Examples of specific applications - Refractometer - Polarimeter - Disposable bioreactors - Extruder for food production - Micro reactors - Reactive control in chemical / pharmaceutical environments - Climatic chambers - Spatial simulation - Electric mobility; battery test - Test benches - Stress test - Crystallization regulation - Lyophilization - Micro structures - Painting plants Accessories included Nozzles for pump connections; screw cap. Various options in power (kW), pump pressure/flow rate and tank size offer a wide range of choice for the customer, adapting better to his needs. Contact us to understand the model that best suits your needs. Simple control panel with large TFT display with lots of information. Front panel of the LAUDA Variocool easily removable for fast maintenance and modifications. Easily upgradeable with different interfaces (analog module, contact module, RS 232/485, Profibus, Ethernet-USB module). USB Type B Interface. Connections located on the back of the Variocool: inlet/outlet pump connection; bypass adjustments. Large frontal pressure display. Pump performance graph of LAUDA Variocool heating chillers. Overview of the technical characteristics of the Variocool LAUDA models. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Control panel 3 - Pressure gauge 4 - Mains switch 5 - Alarm output and module bays 6 - Front panel (ventilation openings only in case of air-cooled devices) 7 - Ventilation openings (on both sides) 8 - Four castors (front castors with locking brake) 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Drain tap 5 - Connecting sleeve for water cooling outlet (only available for water- cooled devices) 6 - Connecting sleeve for water cooling intake (only available for water- cooled devices) 7 - Ventilation grid 8 - Rating label 9 - Power supply 10 - Fuses (up to and including VC 3000 (W)) 1 - Light sensor 2 - Pressure gauge 3 - Mains switch 4 - Entry key and arrow keys 5 - Soft keys (left and right) 6 - USB interface Type B (on the side of the control panel) 7 - TFT display

€17,995.00 ex VAT
€21,414.05 incl. VAT if applicable
Italy
heating & cooling, chillers
Chiller Microcool MC 350 LAUDA-cover
Chiller Microcool MC 350 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Cooling power for the model Microcool MC 350 (measured with ethanol):: - at 20°C, 0.35 kW - at 10°C, 0.27 kW - at 0°C, 0.20 kW - at -10°C, 0.12 kW Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Front panel with ventilation openings 5 - Four feet 1 - Overflow connection 2 - Pump connection, outflow 3 - Pump connection, return flow 4 - Rating label 5 - Alarm output 6 - RS 232 interface 7 - Power supply 8 - Drain screw 9 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€2,913.00 ex VAT
€3,466.47 incl. VAT if applicable
Italy
chillers, laboratory modules
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V-cover
Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V

Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2 (more)900W, 120VACFeatures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA03A1P1-41AA1N Durachill Chiller , -10°C to 70°C, 1400W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA03A1P1-41AA1N Durachill Chiller with Positive Displacement Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA03A1P1-41AA1NCooling Capacity @ 20°C1.4 kWCooling Capacity @ 10°C0.99 kWCooling Capacity @ 0°C0.53 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range45 to 100 psi / 310 to 689 kPaMaximum Pump Flow Rate2.6 gpm / 9.8 lpmPower Requirements120V, 60Hz, 16.2AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(4) { background-color: #fffacd; }

$6,946.00 ex VAT
United States
chillers, heating & cooling