Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Waters
Supplier
Unigreenscheme
Location
Caerphilly - United Kingdom
Price
£500.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

Waters 474 Scanning Fluorescence Detector HPLC Lab

Unigreenscheme£500.00 (ex VAT)
item image

Description by the supplier

Waters 474 Scanning Fluorescence Detector HPLC

This was removed from a university lab where it was surplus to requirements.

The unit powers up and successfully self-tests its ROM, RAM, EM driver, EX driver, lamp energy are good and it reports a lamp operation of 1385.9 hours

It is in good cosmetic condition with minor marks.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Agilent 1100 HPLC System-cover
Agilent 1100 HPLC System

Agilent 1100 system consisting of: 1x Agilent 1100 Degasser type G1379A 2x Agilent 1100 Isocratic Pu (more)mp type G1310A 1x Agilent 1100 Variable Wavelength Detector type G1314A 1x Agilent 1100 Fluorescence Detector type G1321A 2x Solvent tray Manual injector with 1 ml sample loop Laptop Agilent 1100 IsoPump: Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min, Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar (147 psi) Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 VWD: Detection type: Double-beam photometer Light source: Deuterium lamp Wavelength range: 190–600 nm Short term noise (ASTM): ± 0.75 x 10-5 AU at 254 nm Drift: 3 x 10-4 AU/hr at 254 nm Linearity: > 2 AU (5%) upper limit Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Band width: 6.5 nm typical Flow cell: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum Dimensions (HxWxD): 140 x 345 x 435 mm Weight: 11 kg Agilent 1100 FLD: Detection type: Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis Light source: Xenon flash lamp Pulse frequency: 296 Hz for single signal mode, 74 Hz for spectral mode Excitation monochromator: range; 200 – 700 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 300 nm Emission monochromator: range; 280 – 900 nm and zero-order,  bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 400 nm Spectrum acquisition: Excitaiotn or emmision spectra, scan  speed; 28 ms per data point, step size; 1 – 20 nm Wavelength characterisric: Repeatability; ±0.2 nm, accuracy; ±3 nm Flow cell: 8 µl volume and 20 bar pressure, quartz Dimensions (HxWxD): 135 x 345 x 435 mm Weight: 11.5 kg

€13,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Magnetic stirrer for large volumes MSL8 digital Velp-cover
Magnetic stirrer for large volumes MSL8 digital Velp

MSL Digital laboratory magnetic stirrer: for large volumes and low viscosity in the Life Science and (more) Pharmaceutical fields. - Preparations in buffer solution - Buffer preparation and WFI (Water for Injection) - Vaccine production - Cell cultures and tissue cultures Powerful and simple - The brushless motor guarantees continuous operations for high volumes - The LCD display allows you to set the speed precisely - Shakes volumes up to 8 liters (H2O) - Agitation speed from 40 to 1500 rpm - The lightweight design makes the MSL 8 Digital easy to move, saving valuable lab bench space - SpeedServoTM technology guarantees constant speed even when the viscosity changes - Equipped with timer to program your activities (1 to 99 min) In full safety - The control panel is splash protected for maximum durability - The stainless steel top guarantees unparalleled resistance - The lock function eliminates the risk of unwanted setting changes - Designed to last over time - Soft start to keep splashes to a minimum - Reverse timed rotation for effective mixing without increasing speed (5s to 99min55s) - MSL allows you to stop mixing for a certain period with the intermittent timer function. TECHNICAL FEATURES IN BRIEF Stirring system: Brushless motor. Structure: metal with epoxy paint; stainless steel top. Speed ​​range: 10rpm. Feedback: SpeedServo technology Reversal of stirring direction: Yes, from 5s to 99min55s. Continuous operations: Yes. Lock function: Yes. Intermittent mode: Yes. Display auto-off: Yes, after 10 sec.

€214.00 ex VAT
€254.66 incl. VAT if applicable
Italy
stirrers
Radwag MA 50.5Y Moisture Analyzer-cover
Radwag MA 50.5Y Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content &ndash; of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160&deg;C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer&rsquo;s accuracy and sensitivity. 10-Inch Display Bigger screen &ndash; 10&rsquo;&rsquo; &ndash; means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light &ndash; an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note &ndash; Note Down Your Conclusions It&rsquo;s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,390.00 ex VAT
Poland
moisture analysers, balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]