For sale: Refurbished Agilent 1260 Infinity II HPLC system including:

G7111B 1260 Quaternary Pump

G7129A 1260 Vialsampler

G7114A 1260 VWD

OpenLab software

Also available:

Agilent 1100 and 1200 series with DAD, FLD, RID Detectors

Agilent 1100 and 1200 series modules

In combination with MS systems from Agilent

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

For sale: Refurbished Agilent 1260 Infinity II HPLC system including:

G7111B 1260 Quaternary Pump

G7129A 1260 Vialsampler

G7114A 1260 VWD

OpenLab software

Also available:

Agilent 1100 and 1200 series with DAD, FLD, RID Detectors

Agilent 1100 and 1200 series modules

In combination with MS systems from Agilent

 

We are not a agent/reseller. All products on our website are in stock and can be delivered with installation by our own service engineers. All systems are delivered with warranty!

About Lab2

LAB2 is specialized in refurbishment or used analytical instruments of the major brands, like Agilent Tech, Thermo, Waters, Shimadzu, Perkin Elmer, CTC Analytics, Varian and more. Through the years we have developed into one of the most reliable partners worldwide.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
People are watching right now:
Heating magnetic stirrer AREC 4 Digital Velp with probe-cover
Heating magnetic stirrer AREC 4 Digital Velp with probe

AREC 4 Digital was designed for laboratories that have little space available, that need an easily m (more)ovable instrument, but that do not want to give up the power and precision of a magnetic stirrer for a large number of applications. The plate offers high resistance to acids, bases and solvents, while the technopolymer structure of the stirrer is designed to prevent accidental spills of liquids from reaching the electronic components, ensuring easy and quick cleaning. This translates into product safety and durability even in the most demanding laboratories; further protected by a 3-year warranty (subject to online registration). The heating technology uses the latest technologies available and ensures a uniform temperature across the entire plate and exceptional transfer efficiency. Same quality for agitation: SpeedServo™ technology and brushless motor offer precise and powerful agitation even when viscosity varies. In short, why we offer you AREC 4 Digital: - Find space in any laboratory - Easy to use and highly resistant to chemicals - Maximum portability - Precise setting of temperature and agitation - Possibility of precise thermoregulation of the fluid with Pt100/Pt1000 and VTF probes - Designed for durability and guaranteed for 3 years The powerful brushless motor of the AREC 4 Digital ensures stable and reliable stirring. The patented SpeedServo™ technology ensures constant speed even with variations in fluid viscosity. The always precise stirring speed, from chemical reactions to sample preparation, adjustable from 100 to 1500 rpm, ideal for any laboratory need. Arec 4 Digital reaches the remarkable temperature of +550°C in complete safety and control. Extremely precise, you can increase the temperature by +1.0°C. By connecting the external PT100 or PT1000 sensors you can directly thermoregulate the sample up to 350°C with an accuracy of ±1.0°C. Using VTF Digital instead you can control the temperature with a precision of ±0.5°C (up to a maximum of 300°C). In this regard, Arec 4 Digital is available with different accessory packages. You will find all the combinations at the bottom. Safety during rescaling: - 'Hot surface' alarm when temperature exceeds 50°C, even when inactive. - Overtemperature alarm above 570°C 1 - Aluminum heating plate with ceramic coating 2 - Main switch 3 - Knob for stirring setting 4 - Knob for temperature setting 5 - Display

€468.00 ex VAT
€556.92 incl. VAT if applicable
Italy
stirrers
Edwards nEXT240D - CF100 160W Turbomolecular Pump-cover
Edwards nEXT240D - CF100 160W Turbomolecular Pump

Edwards nEXT240D - CF100 160W Turbomolecular Pump Ultimate Vacuum &lt;5x10-10 mbar Inlet Connection  (more)DN100CF Pumping Speed Nominal 14,400.00 l/min Features - Reaches an ultimate pressure of 6×10⁻⁸ mbar for precise vacuum applications - Features built-in electronics compatible with TAG and TIC controllers for easy system integration - Allows for in-field servicing with minimal tooling, reducing maintenance time and cost - Upper magnetic bearing ensures clean vacuum conditions, low power consumption, and reduced vibration - Incorporates a molecular drag stage for improved pumping speed and compression ratios - Designed for long-lasting performance and low cost of ownership, enhancing value - Comes with a standard inlet screen to protect the pump and ensure optimal functionality - Offers a high level of modularity for maximum flexibility and customization nEXT turbomolecular pumps are hybrid bearing pumps with integrated controllers for pumping speeds from 47 to 1250 ls-1.The nEXT is a hybrid bearing compound turbomolecular pump. nEXT pumps combine our proven bearing technology (oil lubricated ceramic lower bearing with dry permanent magnetic upper bearing), an improved rotor design with a new molecular drag stage to deliver improved pumping speed and compression ratios, and user serviceability. They feature 24 V to 48 V DC sensorless motors with a built-in drive that is fully compatible with our range of TAG and TIC controllers.INCLUDED: The Edwards nEXT240D - CF100 160W Turbomolecular Pump includes: - Power Cord - One Year Manufacturer's Warranty

$10,296.00 ex VAT
United States
pumps liquid & other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]