Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
GE Healthcare
Model
ÄKTApurifier UPC10 System
Location
Zevenhuizen - Netherlands
Price
€11,250.00 
(ex. VAT)
This item is
for sale
State of item
used
Categories

GE Healthcare ÄKTApurifier UPC10 System

€11,250.00 (ex VAT)
item image

Description from the supplier

The GE Healthcare ÄKTApurifier UPC10 System is a versatile, modular liquid chromatography system designed for fast and reliable separation of proteins, peptides, and nucleic acids using FPLC (Fast Protein Liquid Chromatography). It is optimized for purifying microgram to milligram quantities of proteins and operates at flow rates ranging from 0.001 to 10 ml/min with pressures up to 25 MPa.

Flow Rate Range:

  • **Isocratic mode**: 0.01 to 100 ml/min in increments of 10 µl/min
  • **Gradient mode**: 0.01 to 100 ml/min in increments of 10 µl/min
  • **Double mode**: 0.01 to 200 ml/min in increments of 10 µl/min

Pressure Range: Up to 10 MPa (100 bar, 1450 psi)
pH Stability Range: 1 to 13 (1 to 14 with exposure <1 day)
Viscosity: Maximum 5 cP
Flow Rate Accuracy (0.2 – 10 MPa): ± 2% or 20 µl/min, whichever is greater
Flow Rate Reproducibility (flow rate ≥ 0.5 ml/min): rsd < 0.5%
Gradient Composition Accuracy: < ±1% at 0.5 to 100 ml/min
Gradient Composition Reproducibility: rsd < 0.25% at 0.5 to 100 ml/min

Pressure Sensor Range: 0 to 27.5 MPa
Offset Error: < 0.05 MPa
Scale Error: < ±2%
Total Volume Between Inlet and Outlet: < 800 µl/module

  • Range: 190 – 700 nm in 1 nm steps
  • Bandwidth: 4 nm
  • Accuracy: ±2 nm
  • Reproducibility: ±0.01 nm
  • Switch Time: < 500 ms (for one cycle from 214 nm to 254 nm and back)
  • Linearity: <2% deviation up to 2 AU at 260 nm with Uracil at pH 2
  • **Single wavelength (short term, 0.5 – 1 min)**: <6×10⁻⁵ AU at 230 nm
  • **Single wavelength (long term, 1 – 10 min)**: <6×10⁻⁵ AU at 230 nm
  • **Dual wavelength (short term, 0.5 – 1 min)**: <2×10⁻⁴ AU at 230 nm and 254 nm
  • **Dual wavelength (long term, 1 – 10 min)**: <2×10⁻⁴ AU at 230 nm and 254 nm
  • **Drift**: <2×10⁻⁴ AU at 254 nm
  • UPC-900 Monitor
  • P-900 Pump
  • P-960 Pump
  • 2x INV-907 Valve
  • 2x PV-908 Valve
  • FRAC-950 Fraction Collector
  • PC
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
GE AKTApurifier 100 - Frac-950 FPLC System, UPC100, P-900, Unicorn 5.20 Lab-cover
GE AKTApurifier 100 - Frac-950 FPLC System, UPC100, P-900, Unicorn 5.20 Lab

GE AKTApurifier UPC100 with Frac-950 Fraction Collector FPLC System This system was removed from a u (more)niversity laboratory where it was surplus to requirements. The system was manufactured in 2010. It is in good cosmetic condition, with minor staining on the AKTApurifier front cover and Frac-950 panels. All units powered on successfully, with the main components passing their respective self-tests. Further functionality testing notes are stated below. Passwords required for the PC and Software are available on request. System Components: - GE AKTApurifier UPC100 - Serial No.: 1554254 - P-900 Pump - Serial No.: 1552104 - UPC-900 Monitor - Serial No.: 1553148 - Box-900 Solvent Tray - Serial No.: 1554254 - Frac-950 Fraction Collector - Serial No.: 1551122 - Dell Optiplex 360 PC - Serial No.: C2BN34J - Operating System: Microsoft Windows XP Professional - Software: Unicorn 5.20, Serial No.: 1546657 Functionality: - The main AKTApurifier unit powered on and displayed “ready to start” after the P-900 pump synchronized and ran successfully. - The UPC-900 monitor calibrated itself and displayed numerical data. - The fraction collector powered on with a functioning cooling fan and a flashing green status light. - The PC powered on, loaded Windows XP Professional, and opened Unicorn 5.20, providing access to control screens for the AKTApurifier and Frac-950. Software Discs: - Unicorn 5.20 Workstation - Unicorn Control Strategies 4.12 Manuals: - Full set of GE AKTApurifier user guides and instructions - Frac-950 User Manuals - Unicorn 5.20 Software User Guides Additional Included Items: - 1 x GE Mono Q5/50 GL column (ID: 0124) - 1 x Pharmacia Biotech Superrose column (ID: 9908036) - 1 x Pharmacia Biotech Mono P column (ID: 99030004) - 1 x Pharmacia Biotech Mono P column (ID: 00140007) - 1 x Superdex 75 column (ID: 9946102) - 1 x Superdex 200 column (ID: 9915040) - 1 x Amersham Biosciences XK16 column - 1 x 240-tube sample holder tray - 1 x 128-tube sample holder tray - 1 x 6-tube and 4-tray position sample holder

£8,000.00 ex VAT
United Kingdom
fplc systems, fraction collectors
GE Healthcare ÄKTApurifier UPC10 System-cover
GE Healthcare ÄKTApurifier UPC10 System

The GE AKTA Purifier 10 FPLC System is versatile, modular liquid chromatography systems for fast and (more) reliable separations of proteins, peptides, and nucleic acids by FPLC. AKTA Purifier 10 is designed for purification of microgram to milligram quantities of protein, operating at flow rates of 0.001 to 10 ml/min at pressures of 0 to 25 MPa. Flow Rate Range: Isocratic mode: 0.01 to 100 ml/min in steps of 10 µl/min Gradient mode: 0.01 to 100 ml/min in steps of 10 µl/min Double mode: 0.01 to 200 ml/min in steps of 10 µl/min Pressure Range: 0 to 10 MPa (100 bar, 1450 psi) pH Stability Range: 1 to 13 (1 to 14 with <1 day exposure) Viscosity: Max 5 cP Flow Rate Accuracy (0.2 – 10 MPa): ± 2% or 20 µl/min, whichever is greater Flow Rate Reproducibility (flow rate ≥ 0.5 ml/min): rsd < 0.5% Gradient Composition Accuracy: < ±1% at 0.5 to 100 ml/min Gradient Composition Reproducibility: rsd < 0.25% at 0.5 to 100 ml/min Pressure Sensor Range: 0 to 27.5 MPa Offset error: < 0.05 MPa Scale error: < ±2% Total Volume Between Inlet and Outlet: < 800 µl/module Wavelength range: 190 – 700 nm in steps of 1nm, 3 wavelenghts simultaneously Bandwidth: 4 nm Wavelength accuracy: ±2 nm Wavelength reproducibility: ±0.01 nm Wavelength switch time: < 500 ms (one cycle from 214 nm to 254 nm and back to 214 nm) Linearity: <2 % deviation up to 2 AU at 260 nm with Uracil at pH 2 Noise: Single wavelength (short term, 0.5 – 1 min): <6×10⁻⁵ AU at 230 nm Single wavelength (long therm, 1 – 10 min): <6×10⁻⁵ AU at 230 nm Dual wavelength (short term, 0.5 – 1 min): <2×10⁻⁴ AU at 230 nm and 254 nm Dual wavelength (long therm, 1 – 10 min): <2×10⁻⁴ AU at 230 nm and 254 mm Drift: <2×10⁻⁴ AU at 254 mm System consists of: UPC-900 monitor P-900 pump P-960 pump 2x INV-907 valve 2x PV-908 valve FRAC-950 fraction collector PC

€11,250.00 ex VAT
Netherlands
fplc systems, hplc systems
People are watching right now:
Adam Equipment EPB 723E Equinox Precision Balance, 720g, 0.001g-cover
Adam Equipment EPB 723E Equinox Precision Balance, 720g, 0.001g

Adam Equipment EPB 723E Equinox Precision Balance, 720g, 0.001g Capacity 720g Readability 0.001g Re (more)peatability 0.001g Features - Large, responsive 5’’ 800x480 pixel touch-screen display - Level indicator and adjustable feet ensure proper balance setup for optimum weighing results - Security slot for optional Kensington-type lock and cable to help prevent theft - Large, grade 304 stainless steel pan allows easy cleaning - RS-232 interface provides speedy connection to computers and printers - USB host for memory card - Built-in memory for storing products and settings - External calibration allows for verification and adjustment with weights ("I" models feature internal automatic calibration) - Selectable digital filtering helps minimize effects of vibration and disturbances - Security password control prevents unauthorized access - Printouts include date and time for data tracking within Good Laboratory Practices (GLP) guidelines - Preset tare function speeds the process of repetitive weighing - Parts counting with freely selectable sample sizes - Multilingual display allows use in many different countries - Memory accumulation totals results - Check weighing with audible alarm The Adam Equipment Equinox Precision Balances deliver remarkable precision to labs that perform highly detailed testing. The Equinox is ideal for research and quality assurance facilities; science education; precision counting; and production and manufacturing applications needing exceptionally precise results. Twelve precision models offer capacities from 360g to 8200g and readabilities of 0.001g and 0.01g. A color touch screen display provides intuitive operation, with icon-driven menus and readily accessible applications and functions. The five-inch screen is generously sized, offering 800 X 480-pixel resolution for excellent visibility. INCLUDED: The Adam Equipment EPB 723E Equinox Precision Balance, 720g, 0.001g includes: - Power Cord - Operator's Manual - Manufacturer's Documentation - 5 Year Manufacturer's Warranty

$2,108.00 ex VAT
United States
balances
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]