Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
E2 Mass Standard - Flat Polygonal Sheet - 5 mg
Location
Radom - Poland
Price
€34.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag E2 Mass Standard - Flat Polygonal Sheet - 5 mg

€34.00 (ex VAT)
item image

Description from the supplier

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research.

E2 class standard: flat polygonal sheet
Nominal value: 5 mg
Material: aluminum

High Precision of measurements

The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component.

Stability over Time

An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry.

Calibration and Strict Quality Control

Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy.

Versatility of Applications

E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements.

Applications

1.
Analytical Laboratories

In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application.

2.
Pharma Industry

In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances.

3.
Scientific Research

In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results.

4.
Metrology Industry

In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards.

E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
Radwag HX7.4P.3000.H Multifunctional Stainless Steel Pallet Scale-cover
Radwag HX7.4P.3000.H Multifunctional Stainless Steel Pallet Scale

The HX7.4P H pallet scale is outfitted with a 4-load-cell mechanical design, made of AISI304 stainle (more)ss steel, which has been invented for weighing pallets. The scale is mainly intended for Euro and transport pallets of respective size, i.e. 800 × 1200 mm. The load can be put onto the pan using a forklift. The scale is controlled via a cutting-edge indicator, the PUE HX7 offering a 7" graphic display and a diode bar graph which signals a current load mass related to the scale range or declared minimum and maximum thresholds. At the back of the housing there are hermetic connectors of RS232, RS485, USB and Ethernet communication interfaces, plus digital inputs/outputs and analogue output. This enables cooperation with external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. With use of the bracket you can either place the indicator at any flat horizontal surface, or fix it to the wall adjusting the tilt respectively to suit your needs. The terminal's software allows carrying out processes such as weighing, parts counting, dosing, labelling, formulations and percent weighing. Indicator’s system of information is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety.

€3,912.00 ex VAT
Poland
pallet & beam scales, beam scales, pallet scales
Radwag MA 50/1.5Y.IC Moisture Analyzer-cover
Radwag MA 50/1.5Y.IC Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€4,054.00 ex VAT
Poland
moisture analysers, balances
Radwag PUE HX5.EX-2 Weighing Terminal-cover
Radwag PUE HX5.EX-2 Weighing Terminal

PUE HX5.EX terminal is a constructional component of industrial multifunctional load cell scales. It (more) is the most modern RADWAG solution to be used in areas endangered with explosive atmosphere. The HX5.EX is compliant with ATEX directive regulations. The terminal is intended for operation in environment filled with explosive gases and dust, and can be placed in zones: 1/21 and 2/22. Standard version of the terminal is equipped with 2 serial intrinsically safe RS232 communication interfaces, and with one intrinsically safe RS485 interface. They facilitate communication with equipment predetermined for use in hazardous areas. Possibility to add digital inputs/outputs expands the range of instruments compatible with the terminal by robotic elements compliant with ATEX directive. For more demanding customers, RADWAG has developed IM01.EX module, installed in the safe area, which extends the available connector range by Ethernet, USB, 4-20mA/0-10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables communication between the terminal and external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Models There are 4 different models: PUE HX5.EX-1: 2 × RS232, RS485 - standard design, PUE HX5.EX-2: standard design + 4IN/4OUT, PUE HX5.EX-3: standard design + 4IN, PUE HX5.EX-4: standard design + 4OUT. Mechanical Design The housing, made of AISI 304 stainless steel, ensures high ingress protection, IP66 / IP68 (up to 1.5 m immersion). The terminal features 5" colour LCD, covered with polycarbonate protecting it against shocks, and a membrane keypad. Ease of operation, clear menu and intuitive information arrangement on the display guarantee comfort of operation. Hermetic intrinsically safe interface connectors are located on the back side of the housing. Stable bracket enables mounting the terminal either on a flat horizontal surface or on the wall. The device tilt can be easily adjusted. Power Supply The PUE HX5.EX terminal can be connected to the mains only with a certified intrinsically safe power supply, manufactured by RADWAG: PM01.EX-1 power supply intended for operation in hazardous area: zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. PM01.EX-2 power supply intended for operation in safe area, equipped with intrinsically safe circuits which may be placed in: zone 1 and 2 where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4. zone 21 and 22 where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA. IM01.EX Communication Module The terminal’s interface range can be expanded using IM01.EX communication module, connected to the terminal via an intrinsically safe RS485 interface, placed outside the hazardous area. Models: IM01.EX-1 Standard: 2x RS232, USB,4 I/4 O, Ethernet IM01.EX-2 analog output 4-20mA/0-10V IM01.EX-3 12 I/12 O, digital IM01.EX-4 Profibus DP IM01.EX-5 PROFINET IM01.EX-6 CANopen (available soon) IM01.EX-7 DeviceNet (available soon) IM01.EX-8 RS485 IM01.EX: ETHERNET IP (available soon) Multifunctional Software Terminal software facilitates processes such as weighing, parts counting, dosing, and percent weighing. Terminal’s information system is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety. The interfaces enable communication between the terminal and the accessories intended for operation in the hazardous and non-hazardous areas. Accessories: barcode scanners, printers, external displays, control buttons, light signalling towers and other controlling/signalling devices. The terminal can communicate with systems for automatic process control and superior IT systems.

€1,288.00 ex VAT
Poland
scales for ex areas, weighing terminals
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]