Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Gilson
Model
Gilson Pipetman
Location
Hampton - United States
Price
$375.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Gilson Pipetman L P5000L 500 - 5000 uL Pipette

$375.00 (ex VAT)
item image

Description from the supplier

Gilson Pipetman L P5000L 500 - 5000 uL Pipette Designed for performance and comfort, PIPETMAN® L comesin a comprehensive range of models adapted to your needs in the lab. Comfortable, precise, accurate, and reliable, use PIPETMAN L pipettesconfidently in your applications. Available as a fixed or variable volume, the PIPETMAN Lair-displacement pipettes cover a full volume range, including:

  • Variable volume single channel models covering a volumerange from 0.2 μL to 10 mL
  • Variable volume multichannel models covering a volumerange from 0.5 μL to 1200 μL, including four models equipped with V-rings (VR)at the bottom of the tip holder for a proper fit with most tip brands, coveringa volume range from 20 µL to 300 µL
  • Fixed volume single channel models covering a volumerange from 1 μL to 5000 μL

Convenient UseLightweight and balanced, PIPETMAN L combines anergonomic design with minimized pipetting forces, giving you the ability topipette longer without fatigue. Right-handed or left-handed? No problem. Adjust thelocation of the tip ejector to the most comfortable position for you. Secure PipettingReduce pipetting errors and avoid accidental volumechanges during pipetting cycles with a true volume-locking mechanism forimproved accuracy and precision. PIPETMAN L variable volume models are all fullyautoclavable without disassembly for maximum convenience and protection fromcross-contamination. Large volume models are equipped with a plastic tipejector to avoid direct contact with the tip and better compatibility withchemicals. Choose Your Tip EjectorFor single channel models, choose between a model with astainless-steel tip ejector or a plastic ejector, depending on your needs andapplications. GLP CompliancePIPETMAN L models feature a DataMatrix 2D code for easytraceability. Use a 2D code scanner to transfer the code automatically into anytraceability or asset management system. Also, the pipette serial number isengraved on the body of the pipette for unique identification.

CLICK HERE TO SHOW GILSON PIPETTE COMPARISON TABLE

  • Operator's Guide
  • 3 Year Manufacturer Warranty


Gilson Pipetman L P5000L 500 - 5000 uL Pipette SpecificationsAdjustable or Fixed VolumeAdjustable VolumePipette TypeManual Air DisplacementVolume Range500 - 5000 µLPipette ModelP5000LPipette RangePIPETMAN LNumber of Channels1Ejector TypePlasticPack Size1Pack Size UnitEachComparison of ModelsSpecificationsP2L (0.2 - 2 µL)P10L (1 - 10 µL)P20L (2 - 20 µL)P100L (10 - 100 µL)P200L (20 - 200 µL)P1000L (100 - 1000 µL)P5000L (500 - 5000 µL)P10 mL (1 - 10 mL)Adjustable or Fixed VolumeAdjustableAdjustableAdjustableAdjustableAdjustableAdjustableAdjustableAdjustablePipette TypeManual Air DisplacementManual Air DisplacementManual Air DisplacementManual Air DisplacementManual Air DisplacementManual Air DisplacementManual Air DisplacementManual Air DisplacementVolume Range0.2 - 2 µL1 - 10 µL2 - 20 µL10 - 100 µL20 - 200 µL100 - 1000 µL500 - 5000 µL1 - 10 mLNumber of Channels11111111.comparison-table tr td:nth-child(8) { background-color: #fffacd; }Request a Formal Quote

Product details

Adjustable or Fixed VolumeAdjustable Volume
Pipette TypeManual Air Displacement
Volume Range500 - 5000 µL
Pipette ModelP5000L
Pipette RangePIPETMAN L
Number of Channels1
Ejector TypePlastic
Pack Size1
Pack Size UnitEach
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Gilson Microman M100E Pipette, 10-100ul-cover
Gilson Microman M100E Pipette, 10-100ul

Gilson Microman M100E Pipette, 10-100ul The ergonomically designed MICROMAN® E positive displacement (more) pipettes, along with disposable capillary piston (CP) tips, provide the highest precision when pipetting viscous, non-aqueous liquids such as oils, blood, glycerol, and more, while protecting the pipette from contamination. MICROMAN E is available in six models covering a volume range of 1 to 1000 µL. MICROMAN E relies on positive-displacement technology to improve the precision of transferring viscous and volatile liquids. The capillary piston (CP) tips eliminate the air cushion between the sample and piston so volume accuracy is not affected by the sample’s properties. Tackle these issues with MICROMAN E: - Viscous solutions—difficult to aspirate and stick to pipette tips. - Volatile solutions—leakages are created from differences between solvent vapor pressure and the air pressure within the pipette. - Cold liquids—delivered in excess amounts. - Hot liquids—under-delivered amounts. Designed with Comfort and Performance in Mind The Red Dot Award winning design of the MICROMAN E features an improved handle shape that rests comfortably in your hand, with a large push button for easy aspiration and dispensing. The volume-locking switch allows for easy volume adjustment and minimizes the risk of accidentally changing the volume during pipetting tasks. Overall Protection The positive-displacement technology of the MICROMAN E is ideal when dealing with infectious solutions and radiolabeled components. Since the disposable piston makes direct contact with the sample, the user and the pipette are protected. Within molecular biology and forensic sciences, any trace of a previous sample can lead to erroneous results and the disposable CP tips provide absolute protection against cross-contamination. INCLUDED: The Gilson Microman M100E Pipette includes: - Operator's Guide - One Year Manufacturer's Warranty

$478.00 ex VAT
United States
pipettes
Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes-cover
Radwag 10 μl ÷ 100 μl - RW8-104-20-9 Automatic Pipettes

RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict s (more)tandards concerning manufacturing cleanliness and biodegradability of the product. The pipettes represent a new line of the 'liquid handling' product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button. All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user. Calibration certificates, issued by the accredited calibration laboratory are available on request. Features: Large and readable display that is fully visible during pipetting; Innovative soft grip preventing heat transfer to the pipette inside; Low pressure required to use the pipette reduces the risk of RSI; Simple click mechanism for changing the pipette volume; Option of autoclaving the whole pipette (disassembling not required). Recommended autoclaving process: 15 minutes at 121°C temperature, 1.05 bar pressure; Tip ejector collar is made of PVDF which has a high chemical resistance (also at high temperatures) and low susceptibility to microorganisms expansion; Ultra UV resistance; Convenient button for changing the tips; Compatible with most of the tips available on the market.

€160.00 ex VAT
Poland
pipettes, pipettes calibration
Radwag MY11 - Adapter for Pipettes calibration 11 ml-cover
Radwag MY11 - Adapter for Pipettes calibration 11 ml

MY11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the MYA microbalance. Set content: weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Vessel capacity: 11 ml Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
ultra microbalances, analytical balances, analytical balances accessories, balances, balances accessories, microbalances, microbalances accessories, pipettes, pipettes calibration, scales, ultra & microbalances accessories
People are watching right now:
IKA T 18 Mini Digital ULTRA-TURRAX Disperser-cover
IKA T 18 Mini Digital ULTRA-TURRAX Disperser

IKA T 18 Mini Digital ULTRA-TURRAX Disperser Speed Range 3000 to 25000 RPM Viscosity Max. 2000 mPas  (more)Stirring Quantity Max. 1.5 l Features - Wide speed range of 3000 – 25,000 rpm for working volumes up to 1.5 liters (H2O) - Compact design with a 40% smaller footprint compared to similar models, ideal for tight lab spaces - Brushless DC motor for improved longevity, quieter operation, and dust-free applications - Digital speed display and stepless speed adjustment for precise control - Clear TFT display for easy readability of speed and timer settings, even from outside a fume hood - Timer function enables unattended operation and ensures reproducible results - Dispersing elements available in stainless steel for chemical resistance or in plastic options for varied applications - Quick-insert design for easy dispersing element changes and convenient cleaning The IKA T 18 Mini Digital ULTRA-TURRAX Disperser is a compact, high-performance dispersing instrument designed for precision and efficiency in small laboratory spaces. With a wide speed range of 3000 to 25,000 rpm, it accommodates working volumes up to 1.5 liters (H₂O) and viscosities up to 2000 mPas. Its space-saving design is 40% smaller than comparable models, making it ideal for tight lab setups without compromising functionality. The brushless DC motor ensures quiet, dust-free operation, extended durability, and reliable performance, while the digital speed display and stepless adjustment enable precise control for a variety of applications. Equipped with a clear TFT display, the T 18 Mini Digital allows easy monitoring of speed and timer settings, even from outside a fume hood. The timer function supports unattended operation, ensuring reproducible results with minimal supervision. Compatible with stainless steel dispersing elements for chemical resistance and plastic options for versatile use, the quick-insert design simplifies element changes and cleaning. Additional features like the USB-C interface enable remote control and parameter documentation using IKA labworldsoft® software, making this disperser a versatile and user-friendly solution for emulsification, homogenization, and particle size reduction.

$1,650.00 ex VAT
United States
dispersers
Invitrogen MPK5000 Neon Transfection System-cover
Invitrogen MPK5000 Neon Transfection System

The Neon Transfection System enables fast and efficient delivery of nucleic acids into all mammalian (more) cell types, including primary, stem, and difficult-to-transfect cells. The flexible and open system allows the user to perform high-quality transfections using optimized or user-defined protocols in three simple steps with as few as 2 x 104 cells per reaction. A novel reaction chamber provides a dramatic increase in transfection efficiency and cell viability. The Neon Transfection System is: Efficient – up to 90% in many cell types, including difficult-to-transfect cells, primary, and stem cells Flexible – easily transfect from 2 x 104 cells to 6 x 106 cells per reaction Simple – easy to use, with a single reagent kit for all cell types Versatile – open system allows electroporation parameters to be optimized freely Specifications Format: Electroporation Pipette Tip System: Neon Transfection System Cell Type: Established Cell Lines, Hard-to-Transfect Cells, Stem Cells, Primary Cells Power Limit: 300 W Current Limit: 3.0 – 6.0 A Reaction Time: 1 sec Voltage Limit: 0.5 – 2.5 kV Classification: Animal Origin-Free, Reduced Serum, Chemically Defined, Low-Protein, Reduced Growth Factors, Xeno-Free Serum Compatible: Yes Compatible Products: Transfection Grade Nucleic Acid purification kits, siRNA vectors, DNA vectors Sample Loading Volume: Depends on kit used Sample Type (Specific): Plasmid DNA, Synthetic siRNA Purity or Quality Grade: Transfection Grade Starting Material (Cell #): 2 x 104 – 6 x 106 cells; Varies by cell type

€3,249.00 ex VAT
Netherlands
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]