Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Sartorius
Model
Sartorius YCP02-1 Pipette Calibration Kit Set incl. Software Picaso YCP02-2
Supplier
PROFCONTROL GmbH
Location
Potsdam - Germany
Price
€1,000.00 
(€1,190.00 incl. VAT*)*if applicable
This item is
for sale
State of item
used
Shipping information

Shipping weight: 15,00 kg

Categories

Sartorius YCP02-1 Pipette Calibration Kit Set incl. Software Picaso YCP02-2

PROFCONTROL GmbH€1,000.00 
(€1,190.00 incl. VAT* )* - if applicable
item image

Description by the supplier

The offered instrument / system is fully functional tested and ready to use. FURTHER DETAILS TO FOLLOW

About PROFCONTROL GmbH

At Profcontrol GmbH we offer reasonably priced lab & research equipment. All devices you find on profcontrol.de are in stock and can be delivered any time. Every product and system is tested and overhauled before being offered in our online shop.

About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag SDKP Workstation for Pipettes Calibration-cover
Radwag SDKP Workstation for Pipettes Calibration

In order to ensure measurement traceability, meet all the requirements resulting from supervision ov (more)er measuring equipment and to facilitate the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration. Application: Calibration of automatic pipettes: with fixed volume with adjustable volume. Unit contents: table for calibration anti-vibration table probe for temperature, humidity and pressure measurement probe for water temperature measurement sink for used water armrests LCD monitor PC with pre-installed software PIPETTES RADWAG power supply keyboard and mouse container for used water Adapters for pipettes calibration a{color:#737373;} Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table presents the minimum reguirements in accordance with ISO 8655 standard. It also enables to select suitable adapter for pipette calibration and respective balance version. td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} } Selected volume1 of apparatus under test V Resolution mg Repeatability and linearity mg Recommended balance 1 µl ≤ V ≤ 10 µl 0.001 0.002 MYA 21.5Y PLUS MYA 21.5Y XA 6/21.5Y.M.A PLUS XA 6/21.5Y.M.A XA 6/21.5Y.M 10 µl < V ≤ 100 µl 0.01 0.02 XA 82/220.5Y.A PLUS XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A PLUS XA 120/250.5Y.A XA 120/250.5Y 100 µl < V ≤ 1000 µl 0.1 0.2 1 ml < V ≤ 10 ml 0.1 0.2 Adapter for pipette calibration MY 11 XA 11 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~10 g ~10 g ~11 g ~65 g ~11 g ~65 g 1 For practical purposes, the nominal volume may be used to choose the balance. [Reference: ISO8655-6:2002, pg. 2] If the standard uncertainty of measurement of the balance is known (e.g. from the balance calibration certificate), it may be used instead of the repeatability and linearity. The standard uncertainty of measurement shall not be more than two to three times the resolution. [Reference: ISO8655-6:2002, pg. 2]

€7,024.00 ex VAT
Poland
pipettes, pipettes calibration
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y.A-cover
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y.A

XA100 pipette calibration adapter enables calibration and/or verification of piston pipettes by mean (more)s of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 100 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
microbalances, microbalances accessories, pipettes, pipettes calibration, scales, ultra & microbalances accessories, ultra microbalances, balances accessories, balances, analytical balances accessories, analytical balances
People are watching right now:
Motic Panthera TEC POL (Digital)-cover
Motic Panthera TEC POL (Digital)

Motic Panthera TEC POL (Digital) Features - UC Plan Achromat objectives (strain-free) for FOV 22mm - (more) Transmitted and transmitted/ incident stand options - Transmitted light: LED/HAL light source interchangeable - Integrated focusable/ centerable Bertrand lens - Motic LightTracer: Coded nosepiece & Digital light intensity knob The Panthera TEC POL series fills a last gap in the Panthera family: Polarization microscopes for all material sciences, ready to handle transparent samples like fibers and foils with their inherent birefringence. The Incident light models for opaque materials work out the specific reflectivity (bireflection) of flat surfaces. To extend the application fields, all microscopes carry an intermediate tube with Bertrand lens to analyze the crystal structure and interference figures of gems, precious stones and minerals.INCLUDED: The Motic Panthera TEC POL (Digital) includes: - 4X/0.1 (WD 30.5mm) Objective - 10X/0.25 (WD 17.4mm) Objective - 40X/0.65/S (WD 0.6mm) Objective - 60X/0.8/S (WD 0.35mm) Objective - Widefield UC-WF10X/22mm with Diopter Adjustment - Dust Cover - Power Cord - Allen Key - Blue Filter - Halogen Bulb - Adjustable Key for Nosepiece - Interference Color Chart - Screws for Metal Extension Support - Operator's Guide Motic Panthera TEC POL (Digital) SpecificationsOptical systemColour Corrected Infinity Optical System (CCIS®)Observation tubeBinocular head, Siedentopf type with built-in digital cameraSensor typeCMOSSensor size1/2.5"Capture resolution5MP (2592x1944)Live display mode (through Wi-Fi)1920x1080 (Full HD)Live display mode (through ethernet)1280x720, 1920x1080 (Full HD)Live display mode (through HDMI)1280x720, 1920x1080 (Full HD)Inclination25º inclinedTrinocular light split-Interpupillary distance48-75mmDiopter adjustmentOn both eyepieces, +/- 4 diopterEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentNosepieceReversed quintuple, coded with single centering holesIntermediate BodyRotatable analyzer 360º, Bertrand lens and slot for compensatorsObjective classificationCCIS® UC Plan Achromatic (strain-free), DINObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)Objective mounting threadW 4/5"x1/36" (RMS standard)StageCircular rotating 360º, lockableStage sizeØ160mmTravel range X&Y1º increments, 0.1º vernier scaleCondenserFocusable and centerable Achromat Swing-out Abbe condenser N.A. 0.90/0.13 (strain-free) and rotatable polarizerDiaphragmIris diaphragmFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentFine focus precision2µmFocusing stroke25mmUpper limit stopUpper limit stop preset but adjustableFilter holderOn top of the illuminator with fixing capTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlIllumination interchangeabilityHalogen/LED and LED color temperature interchangeabilityIllumination featuresMotic LightTracer: Light memory, sleep mode (auto on-off), nosepiece LED light intensity and mode indicatorTransformerInternalPower supply110-240V (CE)Other featuresUSB 2.0 for external camera powerDimensions LxWxH410x300x395mmNet weight9.9kgComparison of ModelsSpecificationPanthera TEC POL (Binocular)Panthera TEC POL (Digital)Panthera TEC POL (Trinocular)Optical systemCCISCCISCCISObservation tubeBinocular head, Siedentopf typeBinocular head, Siedentopf type with built-in digital cameraTrinocular head, Siedentopf typeEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)StageCircular rotating 360º, lockableCircular rotating 360º, lockableCircular rotating 360º, lockableStage sizeØ160mmØ160mmØ160mmTravel range X&Y1º increments, 0.1º vernier scale1º increments, 0.1º vernier scale1º increments, 0.1º vernier scaleFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity control.comparison-table tr td:nth-child(3) { background-color: #fffacd; }DownloadsTechnical Specification Download

$4,969.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]