Hoefer EPS 2A200

€295.00 (ex VAT)
item image

Description from the supplier

Hoefer EPS 2A200 Electrophoresis Power Supply. Two plugs. Maximum voltage 200V. Maximum current 2000 mA. Maximum wattage 200 W. Timer.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Mixed Job Lot of Laboratory Equipment - Hoefer, Sigma, Labnet, Megger, Beckman
        NOTE - THIS IS A SPARES/REPAIRS ITEM-cover
Mixed Job Lot of Laboratory Equipment - Hoefer, Sigma, Labnet, Megger, Beckman NOTE - THIS IS A SPARES/REPAIRS ITEM

This job lot of items comes from a variety of university laboratories. The items were no longer requ (more)ired, collected from various store rooms and facilities. None of these items have been tested at our site - it is likely that some will be spares/repairs, but we anticipate that a reasonable amount should operate well. None of these items have been PAT or electrical safety tested. For this reason, we have marked these as spares/repairs as they should not be used without appropriate electrical safety checks. They are sold as a spares/repairs bundle intended to be purchased by someone who has time to test and where necessary refurbish the units. It is an excellent opportunity for anyone looking to benefit from individual equipment resale. The units have not been tested at all. Hoefer SE250 Mighty Small II Mini Vertical Protein Electrophoresis Unit 8x7 Lab ETP Active Film Electron Multiplier Lab Extreme Networks Black Diamond BD 8800 G48Ta Model - 41515 Switch Module Extreme Networks Black Diamond 8800 MSM-48c Model - 41213 Network Switch Module 15 x Extreme Networks LX4 XENPAK Model - 10114 900369-10-02 Supertech Quiet Air Compressor Model Display Replica of Rhinovirus - Common Cold Virus - A.T.O.M. Corbett CG-1 Palm Cycler Laboratory Thermal Cycler PCR Machine LabTechne FlexGene FFG02FSD Benchtop Thermal Cycler LabBrandenburg Alpha Series Model: 507R High Voltage Power Supply Lab4 x Sigma 13034 Swing Arm Centrifuge Rotor Buckets Lab Labnet Vortemp 56 Microplate Shaking Incubator Lab Welch 2562C-02 Standard Duty Dry Vacuum Pump Lab UVP Gel Documentation System 97-0070-02 w/ Camera & PSU LabNortel Erbium Doped Fiber Amplifier with Key LabNortel Erbium Doped Fiber Amplifier Model FA17UFAC-119C28 with Key Lab Beckman 166 Detector Lamp Replacement Deuterium Lamp Kit - P/N: 538706 Mitsubishi Graphic Operation Terminal Panel GOT1000 Model - GT1275-VNBD Hewlett Packard HP 6890 Series Injector Autosampler G153A LabEdwards AIM-PL-NW25 Active Inverted Magnetron GaugeRank Brothers Model 10 Oxygen Measurement Unit Lab Rank Brothers Lab Model 10 Integrated Oxygen Measurement Unit Rank Brothers Model 10 Lab Integrated Oxygen Measurement UnitRank Brothers Digital Model 10 Integrated Oxygen Measurement Lab Unit Griffin And George LTD Vernier Microscope W/ Box of Various Objectives Hybaid Hybridisation Rotisserie Mini Oven Lab K.E. Developments Backscattered Detector Megger 32 PAT Tester Lab Thermo Scientific 8-Channel Decapper w/ Stand Lab Lot Of Glass Reagent Bottle Stoppers Lab

£500.00 ex VAT
United Kingdom
high voltage power supplies, electrophoresis
Shimadzu MCE-202 MultiNA Microchip Electrophoresis System-cover
Shimadzu MCE-202 MultiNA Microchip Electrophoresis System

This system is used to analyze the size of DNA/RNA samples, with convenientanalytical operability. I (more)t achieves analysis costs on par with agarose gel electrophoresis, and can perform fully automatic analyses of up to 108 samples. Using optimized reagent kits (four types for DNA analysis and one type for RNA analysis), the system achieves a high resolution and high sensitivity. It can significantly improve the workflow for mutation checks in genome editing, and genotype determination. Sample rack: Compatible with 96-well PCR plate and 12/8-strip PCR tube (Shimadzu recommended product) Microchip: Quartz, 23 mm separation channel length, on-chip electrodes (insert up to four microchips) Pretreatment: Automatic sample injection, automatic separation buffer replenishing, automatic chip cleaning Electrophoresis Voltage: Max. rated voltage: 1.5 kV, max. current: 250 μA Analysis Cycle time: Approx. 80 s (using four chips) DNA standard analysis (DNA-1000/premixed). This does not include time required for carrying out the first and final wash and initial analysis. Detection Method: LED-excited fluorescence detector (470 nm excitation wavelength) Separation Size Range: 25 to 500 bp (DNA-500 Kit), 100 to 1000 bp (DNA-1000 Kit), 100 to 2500 bp (DNA-2500 Kit), 100 to 12000 bp (DNA-12000 Kit), Up to 28S rRNA (5.0 knt) (RNA Kit) Resolution: 5 bp (25 to100 bp), 5% (100 to 500 bp), 10% (500 to 1000 bp), 20% (1000 to 12000 bp) Sizing Accuracy: ±5 bp (25 to 100 bp), ±5% (100 to 500 bp), ±15% (DNA-1000, DNA-2500, DNA-12000) Required Sample Volume: DNA analysis: Premix mode: 2 to 10 μL (after mixing with marker solution: 6 to 30 μL), On-Chip Mixing mode: 5 to 30 μL, RNA analysis: Premix mode: 3 to 15 μL (after mixing with marker solution: 6 to 30 μL), In the Premix mode, the marker solution is mixed with the sample before loading in the instrument, In the On-Chip Mixing mode, the sample and marker solution are loaded separately and mixed on the microchip under program control. Maximum Salt Concentration: DNA analysis: 10mM Tris-HCI containing 125 mM KCl or NaCl max, RNA analysis: 10mM Tris-HCI, containing 1 mM EDTA max. Min. Detection Limit: DNA analysis: 0.2 ng/μL (at 10mM Tris-HCI buffer, containing 50 mM KCl and 1.5 mM MgCl2), RNA analysis: 5 ng/μL (total RNA), 25 ng/μL (mRNA) (at 10 mM Tris-HCI buffer, containing 1mM EDTA) Quantitation Range: DNA analysis: 0.5 to 50 ng/μL (at 10mM Tris-HCI, containing 50 mM KCl and 1.5 mM MgCl2), RNA analysis: 25 to 500 ng/μL (total RNA), 25 to 250 ng/μL (mRNA) (10 mM Tris-HCI buffer, containing 1 mM EDTA) Quantitation Accuracy: DNA analysis: ±30% (at 10 mM Tris-HCI buffer, containing 50 mM KCL) (DNA-500, DNA-1000, and DNA-2500 Kits), ±40 % (DNA-12000 kit. Quantitative accuracy is based on verification from 200 bp to 12000 bp.) Quantitation Repeatability: RNA analysis: CV 10% or less (CV 20% or less for eukaryotic-origin total RNA at concentrations of 150 ng/μL or more) Dimensions (WxDxH): 415 x 545 x 508 mm Weight: 43 kg

€4,499.00 ex VAT
Netherlands
electrophoresis
People are watching right now:
Avantes HortiSpec+ Spectrometer System-cover
Avantes HortiSpec+ Spectrometer System

HortiSpec+ equipped with a NR Lite2 Net Radiometer probe. The HortiSpec was developed to measure the (more) light intensity and spectral distribution in the visible and NIR range inside greenhouses. Plant growth and the photo synthesis depends very much on light intensisty and spectral distribution of the light intensity. The light intensity can be measured with the HortiSpec in Photons or other parameter, specific for the Horticulture. NR Lite2 is designed for routine measurement of net radiation which is the balance between incoming and outgoing radiation under outdoor conditions. The design of the NR Lite2 is unique. The double-sided detector has black conical absorbers with an anti-stick weather resistant protective coating. In contrast to other sensor designs, NR Lite2 requires no fragile plastic domes. This results in a virtually maintenance free design. The vertical stick prevents birds from affecting the output signal. Spectrometer: AvaSpec – 2048, CCD linear array 2048 pixels Grating VA, wavelength range (300 – 1100 nm) 200 µm slit, Detector collection lens, Order sorting coating Data communicaton: USB version 2.0, 480 mbps Aperture: Diffusor, diameter 3.9 mm Software: HortiSpec Irradiance software Measurement units: photon flux in µmol/s.m² Parameters: Lux, PAR, Blue, Yellow/Green, Red, Far red Specifications NR Lite2: Spectral range (overall): 0.2 to 100 µm Sensitivity: 10 µV/W/m² Response time: < 20 s Operational temperature range: -30 °C to +70 °C

€3,950.00 ex VAT
Netherlands
nmr spectrometers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]