Categories

ZWIEBEL 5g calibration weight class M1 INOX

Biomatyx
item image

Description by the supplier

ZWIEBEL 5g calibration weight class M1 INOX

Laboratory calibration weight in stainless steel

Brand: ZWIEBEL

Weight: 5 g

Type / class: M1

maximum permissible error: ± 1.6mg

LZ 67

Weight checked on a precision balance at 0.01g (10mg) - see photo

In its plastic box

uncalibrated weight

About Biomatyx

Biomatyx is a used laboratory equipment supplier with a varied and competent network. The company operates as a distributor internationally and buys and sell used machinery and equipment for analytical, chemical, pharmaceutical and medical laboratories.

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
LAUDA Proline PV 15 C heating thermostat-cover
LAUDA Proline PV 15 C heating thermostat

Proline heating thermostat with tank Proline clear-view LAUDA thermostats have been designed for dir (more)ect observation of objects. They are ideal for use with LAUDA Scientific PVS or iVisc automatic viscometer, as the necessary temperature stability for precise viscosity determination is ensured over the entire temperature range. In addition, the two-chamber principle always guarantees a constant liquid level in the measuring chamber, regardless of the volume and temperature of the medium. PVL models with five layers of insulating glass are suitable for low temperature measurements down to -40° or -60°C when a low temperature chiller or thermostat is connected. These thermostats are available with two different control units. The Master version is designed for all applications where the parameters are not changed very often. The removable Command operating unit (PV C models) incorporates a graphic LCD screen for high operating convenience and a programmer. Notable features - LAUDA Vario Flex pump (pressure pump) with eight selectable power levels - Cooling coil fitted as standard with connection for additional cooler Accessories included Fittings for pump connection, cooling coil Specific features of the Proline PV 15 C model - Tank volume min. 11 L - Tank volume max. 15 L - Tank opening 230 x 135 mm - Bowl depth 320 mm - Usable depth 285 mm - Upper height of the tank 390 mm - State-of-the-art Command control panel, removable, for remote use; LCD display with the most advanced feature set in the LAUDA range - Pump pressure mx. 1.1 bar - Water-cooled temperature range from 20°C to 230°C - Operating temperature range from -30°C to 230°C - Pump connectors M16 x 1 - Fitting 13 Ø

€9,528.00 ex VAT
€11,338.32 incl. VAT if applicable
Italy
thermostats
Pacific Biosciences PacBio Sequel DNA Sequencing System Lab-cover
Pacific Biosciences PacBio Sequel DNA Sequencing System Lab

Pacific Biosciences Sequel DNA Sequencing System This was removed from a university lab where it was (more) surplus to requirements. The unit powers up. The PSU is included. The system boots up but shows errors in relation to a smrt link server. There was no smrt link server on the client's network which is what caused this issue. It is in very good cosmetic condition but has a dent on one of the panels. Comes with:-(Boxed) Solid State Cooling SystemsModel - UC180PN - 10-180-G1-P20-RSN - 8008262No power supply to test. 1 x 30amp twist lock to 32amp 240volt cable Consumables:-1 x Sealed Pack of TX1009 AlphaWipe Polyester Wipers 9" x 9" (75 Wipes)1 x Sealed Pack of TX404 Absorbond Polyester Wipers 4" x 4" (300 Wipes)2 x Bottles of Sequel Coolant - Dynalene PG 30% - Both expired 2018/1921 x Pacific Biosciences 96 well Verification Plates6 x Bio-Rad Hard Shell 96-Well Sample Plates1 x Pacbio Sequel Pipet Tips v2 (sealed)1 x Pacbio Sequel Pipet Tips (31 tips left)2 x Boxes Sequel SMRT Cell Oil (5 left in one/6 left in other)1 x Tecan Conductive 200ul 96pcs rack (no tips)4 x Packs SMRT Cell Mechanical (1 sealed/3 opened)4 x Packs Pacbio Tube Septa (10 per pack)1 x Pack of 11 Pacbio 0.5ml Empty NFC Verification Tubes1 x Thermal Block1 x Pack TX759B CleanTips Swabs (100 Swabs, Sealed)1 x Uline Kapton Tape1 x Red Ethernet Cable2 x Pacbio Sequel Sample Plate Adhesive Foil

£10,000.00 ex VAT
United Kingdom
dna sequencers, laboratory supplies other
Radwag MA 50/1.5Y Moisture Analyzer-cover
Radwag MA 50/1.5Y Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
balances, moisture analysers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]