Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Ohaus
Supplier
Marshall Scientific
Location
Hampton - United States
Price
$3,570.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Ohaus MB62 Moisture Analyzer

Marshall Scientific$3,570.00 (ex VAT)
item image

Description by the supplier

Ohaus MB62 Moisture Analyzer



Maximum Capacity

90 g

Readability Moisture Content

1 mg / 0.01%

Recommended Moisture Content

0.5% to 100%



Features

- Advanced 90g capacity analyzer with 1 mg/0.01% readability for precise moisture determination.

- Carbon fiber heating for rapid, consistent heating across various applications.

- Moisture range from 0.01% to 100%, suitable for diverse materials

- Temperature range of 40°C to 200°C

- Large 3.5 in (90 mm) pan supports substantial sample volumes

- 5" LCD display with a second line for clear results display including RG%, temperature, and more

- Multiple heating profiles (Ramp, Standard, Step, Fast)

- ID management for accurate sample tracking and repeatability.

- Flexible shut-off criteria including Timed, Manual, and five auto settings

- Multi-color status light provides visual feedback on operation status





The Ohaus MB62 Moisture Analyzer is a state-of-the-art instrument designed to provide highly accurate moisture content determination across a variety of applications. With its advanced 90g capacity and precise 1 mg/0.01% readability, this analyzer is well-suited for handling complex, moisture-sensitive materials. The MB62 utilizes carbon fiber heating technology, delivering rapid and uniform heating, which is critical for consistent and reliable results.


Equipped with a large 3.5 in (90 mm) pan, the MB62 supports substantial sample volumes, making it ideal for high-throughput settings. The analyzer features a broad temperature range of 40°C to 200°C and multiple drying profiles (Ramp, Standard, Step, Fast) to adapt to different analytical needs. A 5" LCD display with a second line ensures clear visibility of critical data such as RG%, temperature, and moisture content. Additionally, the MB62 incorporates ID management for meticulous sample tracking and repeatable results. With its flexible shut-off criteria and a multi-color status light for operational feedback, this moisture analyzer excels in delivering both precision and efficiency in moisture analysis.

INCLUDED:

The Ohaus MB62 Moisture Analyzer includes:

- 3.5 in. Pan

- In-Use Cover

- Box, Aluminum Sample Pans

- Pan Holder

- Pan Handle

- 5 Glass Fiber Pads

- Power Cord

- Operator's Guide

- Manufacturer's Documentation

- 2 Year Manufacturer's Warranty

Product details
Maximum Capacity90 g
Readability Moisture Content1 mg/0.01%
Pan Size3.5 in (90 mm)
Heater TypeCarbon fiber
CommunicationUSB device; RS232
Recommended Moisture Content MC%0.5 % - 100 %
AdjustmentTemperature Adjustment - Mechanical (100℃, 160℃); Weight Adjustment - External (50g)
Dimensions13.9 in x 5.4 in x 8.3 in (352 mm x 138 mm x 210 mm) (LxHxW)
Display5" LCD with 2nd line display
Display ResultsRG%; Temperature; DC%; Time; Method No.; MC%; Weight
Heating ProfilesRamp; Standard; Step; Fast
ID ManagementSample ID
In-Use CoverIncluded
Moisture Range0.01 % – 100 %
Net Weight9.5 lb (4.3 kg)
Operating Range (Temp.)10 °C – 40 °C
Operation InstructionsGraphic Instruction; On-screen Instruction; Progress Indicator
Repeatability0.018% (10g sample); 0.10% (3g sample)
Shut-Off CriteriaTimed; 5 Auto; Manual
Status LightMulti-color status light
Stored Results100
Temperature Range40°C to 200°C
Test Library20
Electrical Requirements120 VAC 50/60 Hz
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag MA 210.X2.A.NS Moisture Analyzer-cover
Radwag MA 210.X2.A.NS Moisture Analyzer

MA X2.A moisture analyzers are hi-tech measuring instruments intended for quick determination of rel (more)ative moisture content, dry mass content and other parameters in samples of different substances. MA.X2.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X2.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X2 Series moisture analyzers: Automatic opening and closing of the drying chamber 5” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X2.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€1,836.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 50/1.5Y.WH Moisture Analyzer-cover
Radwag MA 50/1.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,620.00 ex VAT
Poland
moisture analysers, balances
Radwag MA 110.5Y.WH Moisture Analyzer-cover
Radwag MA 110.5Y.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€3,510.00 ex VAT
Poland
balances, moisture analysers
Radwag MA 200/1.5Y.IC.WH Moisture Analyzer-cover
Radwag MA 200/1.5Y.IC.WH Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€7,658.00 ex VAT
Poland
balances, moisture analysers
Ohaus MB92 Moisture Analyzer-cover
Ohaus MB92 Moisture Analyzer

Ohaus MB92 Moisture Analyzer Maximum Capacity 90 g Readability Moisture Content 1 mg / 0.01% Recomme (more)nded Moisture Content 0.5 % to 100 % Features - 90g capacity with 1 mg/0.01% readability for precise measurements - Carbon fiber heating for rapid and even heat distribution - 4.3” capacitive touch screen with full-color display for easy navigation - Drying profiles include Ramp, Standard, Step, and Fast for flexibility - ID management supports Sample Name, Sample ID, and Batch ID - Temperature range of 40°C to 200°C for various testing needs - Multi-color status light provides at-a-glance progress updates - Shut-off options include Timed, Manual, Auto, and custom settings - Live drying curve and on-screen instructions for real-time monitoring - Stores up to 200 results and 20 methods for high-throughput use - Durable PBT housing with tool-free cleaning for easy maintenance Robust and durable with the new carbon heating technology and an upgraded full color capacitive touchscreen. Flexible drying profiles, and methods provide versatile method creation, with enhanced password protection ensures data security. The full glass panel and tool-free heating chamber make cleaning easy, ideal for both laboratory and production floor use. The Ohaus MB92 Moisture Analyzer combines precision and versatility for demanding moisture analysis applications. With a maximum capacity of 90g and readability of 1 mg/0.01%, the MB92 ensures accurate measurements across a moisture content range of 0.5% to 100%. Its advanced carbon fiber heating technology delivers rapid and consistent heat distribution, while the full-color 4.3” capacitive touchscreen offers intuitive navigation and control. Designed for flexibility, the MB92 features four drying profiles (Ramp, Standard, Step, Fast) and multiple shut-off criteria, including Timed, Manual, Auto, and custom settings. Enhanced ID management supports Sample Name, Sample ID, and Batch ID, enabling efficient sample tracking. Additionally, the device’s durable PBT housing and tool-free heating chamber assembly make maintenance straightforward. Capable of storing up to 200 results and 20 methods, the MB92 is ideal for high-throughput environments that demand robust performance and easy operation. INCLUDED: The Ohaus MB92 Moisture Analyzer includes: - 3.5 in. Pan - In-Use Cover - Box, Aluminum Sample Pans - Pan Holder - Pan Handle - 5 Glass Fiber Pads - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$4,165.00 ex VAT
United States
moisture analysers
People are watching right now:
Pharmacy refrigerator P700 B-Medical-Systems-cover
Pharmacy refrigerator P700 B-Medical-Systems

PRECISION REFRIGERATOR FOR PHARMACIES manufactured by B Medical System SECURITY AND PEACE OF MIND -  (more)Forced air cooling system for uniform and stable temperature distribution - Rapid recovery of the temperature even in case of frequent openings of the door - Safety thermostat that prevents the internal temperature from going below zero - Extended autonomy in the event of a power failure - Audiovisual alarm system with remote transmission via SMS or email - Optional °B Connected universal software for remote monitoring, reporting (in accordance with FDA 21 CFR Part 11) and long-term archiving in combination with a data communication unit CONSTRUCTION AND TECHNOLOGY TO INCREASE THE EFFICIENCY OF THE REFRIGERATOR - Natural refrigerant with high cooling efficiency compliant with US SNAP and EU F-Gas regulations - Polypropylene structure injected with polyurethane foam that provides strong thermal insulation - 4-layer PMMA organic glass door offering maximum insulation, combined with weight reduction to reduce door closing efforts - Automatic internal LED lighting for lower energy consumption - Monobloc structure made with the exclusive rotational molding technique COMFORT OF USE AND DURABILITY - Easy access to parameters on a 7' touchscreen with temperature display - NFC card/password protected door lock mechanism - USB port and SD card slot for easy data export - Antibacterial coating for easy hygiene control - Silent - Low heat emission - Modular internal equipment - Easy access to lower drawers - Stainless steel and other high quality materials for durability PREMIUM Technology: New B Medical Systems 7" touchscreen display integrated into the door handle with pre-installed connection enabling unique monitoring capabilities; simplified door lock mechanism, with a large, heavy-duty handle; access/lock the opening using an NFC card; USB port and SD card slot. The main differences between the Precision line and Premium line series, in addition to the control panel, are the handle, ergonomic and patented by B Medical Systems for the premium line and the shape of the interior. Download the technical data sheet in Italian or in English for all the details.

Italy
refrigerators
Radwag HX5.EX-1.3.H2 One Load Cell Platform Scale-cover
Radwag HX5.EX-1.3.H2 One Load Cell Platform Scale

The HX5.EX scale is a modern weighing instrument assuring fast and reliable measurement in hazardous (more) areas classified as zones 1/21 and 2/22. To ensure precision and excellent measurement repeatability, high quality electronic components are used. The weighing platforms offered in wide range of dimensions and maximum capacities, this combined with excellent metrological parameters enables easy selection of an instrument that meets the most demanding requirements. Standard version of the scale is equipped with 2 serial, intrinsically safe RS232 communication interfaces, and with one RS485 interface. They facilitate cooperation with equipment intended for operation in hazardous areas. Possibility to add digital inputs/outputs extends the range of instruments compatible with the indicator by automatic elements compliant with ATEX directive. More demanding customers can use the IM01.EX module, installed in the safe area, which extends the available connectors by Ethernet, USB, 4-20mA/0- 10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables cooperation with external devices: barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems. Scale operation requires use of a dedicated PM01.EX power supply, which is not a standard scale component. To operate the scale, order a selected type of the dedicated intrinsically safe power supply. Power supply types: PM01.EX-1 - power supply for operation in ATEX area. Used when it is required to connect the power supply to voltage source placed in hazardous area. PM01.EX-2 - power supply for operation outside ATEX area. Used when power supply connection to voltage source is carried out outside hazardous area. Complex software enables carrying out many tasks connected with mass measurement, e.g. parts counting, checkweighing and statistics. The scales feature user-friendly graphic interface, which can be customized using widgets. This and the large colour display of high resolution guarantee easy and clear transmission of data on current process. Colour bar graph significantly influences performance by signalling whether the weighing result is within declared thresholds or not.

€3,566.00 ex VAT
Poland
platform scales, scales for ex areas
Radwag AVK 1000.5Y Automatic Vacuum Mass Comparator equipped with pumps-cover
Radwag AVK 1000.5Y Automatic Vacuum Mass Comparator equipped with pumps

RADWAG-manufactured AVK-1000 automatic vacuum mass comparator is intended for national metrological  (more)institutes that transfer and maintain the national reference mass standard of 1 kg. The comparator is intended for weighing mass standards and silicone spheres of 100 mm diameter. It enables comparison of up to 6 prototypes of max 1kg mass. The repeatability of the process is of 0.3 µg and readability of d = 0.1 µg. A specially designed vacuum chamber enables carrying out measurements in a vacuum of 10-6 mbar capacity or in atmosphere containing noble gases. AVK-1000 is equipped with suspended weighing pan that eliminates eccentricity errors. Standard version of the mass comparator features thermo-hygro-barometer for testing ambient conditions with great accuracy: pressure of 0.001hPa, humidity of 0.01% and temperature of 0.001 °C. The comparator is also equipped with high quality vacuum gauge. The AVK-1000 vacuum mass comparator can be equipped with the LOAD LOCK system for carrying mass standards. The system enables switching or adding artefacts without changing the atmosphere inside the main chamber. With the use of a special chamber for mass standards switching the whole process is 90% shorter. During mass standards replacement carried out without the use of the LOAD LOCK system, the air enters the main chamber of the mass comparator. After each opening of the chamber it is necessary to pump the air out in order to obtain required vacuum value. The vacuum mass comparator needs approx. 48 hours in order to obtain vacuum that ensures measurement repeatability. The LOAD LOCK is equipped with a high-efficiency pump system, the time of pumping the air out in order to enable opening of the valve of the main chamber is significantly shortened. The stabilization of the main chamber after replacing/adding the mass standard and closing the valve connecting the main chamber and the LOAD LOCK system takes 5 hours. The high-quality vacuum gauges enable monitoring and comparing the vacuum value in order to determine the moment when opening the valve again and replacing the mass standard is available. A specially designed viewfinder enables monitoring of the process. The LOAD LOCK enables switching objects of dimensions adapted to the AVK-1000 mass comparator: cylindrical mass standards of 22-95 mm diameter and silicone spheres of 40-100 mm diameter. Supplementing the AVK-1000 vacuum mass comparator with LOAD LOCK system significantly improves the comparison performance.

Poland
mass comparators
Radwag MWMH 500-1 Electromagnetic Compensation Weighing Module-cover
Radwag MWMH 500-1 Electromagnetic Compensation Weighing Module

MWMH series modules are not offered or distributed in the following countries: Germany, Switzerland, (more) Italy, Japan and the USA. Vast Max Capacity Range Magnetoelectric weighing modules MWMH are intended for mass measurement ranging from 1kg to 10kg. Minimum readability of 0.01g guarantees amazing accuracy for your measurement. Protection Against Challenging Conditions Hermetic versions of modules feature stainless steel housing with IP65 and IP69K. This allows operation even in the most challenging conditions. Mechanical design lacks sharp edges and gaps which ensures adherence to HACCP, GMP and FDA standards for safety and quality of operation. Fast and Precise Measurement High measurement accuracy with sd=1d* guarantees both readout of real weighing results and repeatability of indications. Cutting-edge design solutions provide fast measurement which is an asset allowing to install the module on automated production lines. Intended for fast and dynamic measuring processes the weighing module’s converter throughput is 3200 meas./s. Cooperation with terminals Connecting the module to a multifunctional weighing terminal expands communication interfaces range and increases usage in industrial applications. Mechanical design versions: MWMH xxx - 1 - model with Binder connectors (IP65), MWMH xxx - 2 - model with Binder connectors, (IP65), power supply and control of the transporter on a weighing pan, MWMH xxx - 3 - model with cable glands, (IP 69K), MWMH xxx - 4 - model with cable glands (IP69K), power supply and control of the transporter on a weighing pan MWMH xxx - TWD - model with cable glands (IP 69K).

€5,084.00 ex VAT
Poland
weighing modules
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]