Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Lauda
Location
Milano - Italy
Price
€3,295.00 
(€3,921.05 incl. VAT*)*if applicable
This item is
for sale
State of item
new
Categories

Chiller Microcool MC 600 LAUDA

€3,295.00 
(€3,921.05 incl. VAT* )* - if applicable
item image

Description from the supplier

The LAUDA Microcool series offers dependable circulation chillers, ensuring continuous operation for laboratory and research needs spanning temperatures from -10 to 40°C. This line comprises four user-friendly, compact models, equipped with an expansive LED screen and a membrane keypad, delivering cooling capacities ranging from 0.25 to 1.2 kW. Their superior performance relies on their industry-leading centrifugal pump with magnetic coupling, a novel feature in this price range. This magnetic relationship between the pump and electrical motor mitigates sealing issues on the pump shaft.

Two models, the MC 250 and MC 350, are sized to comfortably fit on laboratory countertops. Their larger counterparts, the MC 600 and MC 1200, provide 600 and 1200 watts of cooling capacity and can be conveniently placed on the floor or beneath laboratory benches to optimize space. Moreover, the water-cooled version of the MC 1200 W, our most robust model, is available.

Key Features:

  • Start timer and power-off function
  • Top-filling inlet and rear drain connection
  • Solenoid valve controlled cooling capability with automatic compressor control

Potential Applications:

  • Rotary evaporators
  • Distillation systems
  • Spectrometers
  • Cooling trap supply
  • Digital printing
  • Laser cutting
  • Spot welding
  • Injection molding
  • Tunnel drilling machines
  • Centralized coolant supply

Included Accessories:
Pump connection nozzles, screw cap.

The LAUDA Microcool CHILLER showcases its pump performance graph on a simplified three-button control panel accompanying a display and three LED indicators for, required heat transfer liquid, active cooling unit, and device issues.

The Microcool's rear panel offers: RS232 connection, drainage screw, and external alarm output. The Microcools also have inlet/outlet pump connections and an overflow connection.

The front of the device includes the liquid level indicator and a filler cover. The easily removable front panel of the Microcool LAUDA allows fast filter maintenance.

Pressure Gauge
The MC600 and MC 1200 models, equipped with bypasses, include a pressure gauge for easy pressure measurement.

Product details

Temperature °C-10...40
Control panelDisplay LED
Pump pressure max. bar1,3
Pump Pressure max. l/min.35
Tank volume l4...8
Temperature stability °C+/- 0,5
SeriesMicrocool
Cooling output at 20 °C W0.600 kW @ 20°C
VariousIP 32 protection
Weight kg51
Supply230 V; 50 Hz
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Diagenode Mini-Chiller Water Cooler-cover
Diagenode Mini-Chiller Water Cooler

This listing is for a Diagenode Mini-Chiller Water Cooler .The unit is in full working condition and (more) is ready for immediate release.The Diagenode Mini-Chiller is a compact and versatile cooling unit tailored for laboratory settings, particularly designed to enhance the performance of the Bioruptor® Pico sonication system. Here’s a closer look at its features and benefits:Key Features:Compatibility with Bioruptor® Pico: The Mini-Chiller is specifically designed to work seamlessly with the Bioruptor® Pico, which employs gentle sonication techniques. This compatibility helps preserve the integrity of delicate biological samples such as DNA and RNA during processing.Stable Operating Conditions: By maintaining constant temperature, pressure, and throughflow quantities, the Mini-Chiller ensures optimal conditions for sonication and other laboratory processes, reducing the risk of sample degradation.Cooling Options: Available in both air-cooled and water-cooled versions, the Mini-Chiller offers flexibility based on laboratory needs. The water-cooled version utilizes natural refrigerants, making it an eco-friendly choice.Wide Temperature Range: The Mini-Chiller supports a broad temperature range, extendable up to +100°C when equipped with an optional heater. This feature allows for versatility in various experimental protocols that may require heating in addition to cooling.Compact Design: With dimensions of 225 x 360 mm, the Mini-Chiller is designed to fit easily on laboratory benches, making it an ideal choice for space-constrained environments without sacrificing performance.User-Friendly Indicators: The unit includes a large temperature indicator, a fill level indicator, and status LEDs for pump, cooling, and heating functions. These features enhance usability, allowing researchers to monitor conditions and ensure proper operation at a glance.

£500.00 ex VAT
United Kingdom
chillers, heating & cooling
Chiller Microcool MC 1200 LAUDA-cover
Chiller Microcool MC 1200 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models MC 600 and MC 1200 with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor or under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Pressure gage 5 - Front panel with ventilation openings 6 - Four casters with locking brake 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Overflow connection 5 - Rating label 6 - RS 232 interface 7 - Alarm output 8 - Power supply 9 - Drain screw 10 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€4,059.00 ex VAT
€4,830.21 incl. VAT if applicable
Italy
chillers, laboratory modules
Chiller Microcool MC 600 LAUDA-cover
Chiller Microcool MC 600 LAUDA

Circulation chillers for reliable continuous operation in laboratory and research applications from  (more)-10 to 40°C The LAUDA Microcool line, simple, easy to use, consists of four compact models with large LED display and membrane keyboard, which offer cooling capacities from 0.25 to 1.2 kW. The strong point of these devices is the high-quality centrifugal pump with magnetic coupling - unique on the market for this price category: the magnetic coupling of the pump and the electric motor prevents any kind of sealing problem on the pump shaft. The MC 250 and MC 350 models easily fit on a laboratory bench. Larger models MC 600 and MC 1200 with 600 and 1200 watts of cooling capacity are also available, which can be placed on the floor or under a laboratory bench to save space. In addition, the MC 1200 W, the most powerful device, is also available in a water-cooled version. Notable features - Auto start timer and auto power off function - Top filling opening, drain connection on the back - Cooling capacity adapted via solenoid valve control, including automatic compressor control Examples of specific applications - Rotary evaporators - Distillation systems - Spectrometers - Supply of cooling traps - Digital print - Laser cut - Spot welding - Injection molding - Tunnel drilling machines - Centralized cooling water supply Accessories included Nozzles for pump connections; screw cap Performance graph of the pump of the LAUDA Microcool CHILLER. Simple three button control panel, with display and three LED indications: heat transfer liquid required; active cooling unit; device error. Connections on the back of the Microcool: RS232; drain screw; external alarm output. Connections on the back of the Microcools: inlet/outlet pump connection; overflow connection. Front liquid level indicator. Front cover for filling. Front panel of the Microcool LAUDA easily removable for fast filter maintenance. TECHNICAL VISUALIZATION 1 - Filler nozzle with cover 2 - Level indication 3 - Operating unit 4 - Pressure gage 5 - Front panel with ventilation openings 6 - Four casters with locking brake 1 - Pump connection, outflow 2 - Bypass adjusting wheel 3 - Pump connection, return flow 4 - Overflow connection 5 - Rating label 6 - RS 232 interface 7 - Alarm output 8 - Power supply 9 - Drain screw 10 - Ventilation openings 1 - Display 2 - LEDs 3 - Control buttons 4 - Main switch Liquid level indicator a - Max. level b - Min. level Pressure gauge The models with bypass (MC600 and MC1200) are equipped with a pressure gauge to read the set pressure.

€3,295.00 ex VAT
€3,921.05 incl. VAT if applicable
Italy
chillers, laboratory modules
Polyscience LM61GX1A110C LM6 Benchtop Chiller , -10°C to 30°C, 560W; 120V-cover
Polyscience LM61GX1A110C LM6 Benchtop Chiller , -10°C to 30°C, 560W; 120V

Polyscience LM61GX1A110C LM6 Benchtop Chiller with Centrifugal Pump, 120V, 60Hz3D Visualization of t (more)he Polyscience Benchtop ChillerThe rendered image can be freely rotated in a full 360-degree view, allowing you to zoom in, pause, and explore every angle. For enhanced detail, the rendering can also be displayed in full-screen mode. This 3D model is designed exclusively for visualization purposes and may not accurately represent the actual appearance of your product. Your browser does not support iframes. LM-Series and MM-Series Compact Chillers provide cooling power for demanding applications and serve as economical alternatives to tap water cooling systems. They feature a microprocessor-based controller, digital temperature display (C or °F), and simple operation and maintenance. To optimize cooling efficiency and performance, these sophisticated Chillers also feature a modulated refrigeration system. As a result, temperature stability is greatly enhanced and compressor life extended. LM-Series and MM-Series Chillers are equipped with a magnetic drive centrifugal pump. Wetted parts within the recirculation system are brass, copper, stainless steel, EPDM rubber, Alcryn, nylon, PVC, and polyethylene. Features Optimized for performance at low temperatures Ideal for benchtop rotary evaporators Large, easy to read LED display Space-saving design Cooling at ambient temperatures as high as 35C Low flow shutoff and alarm, high and low temperature alarms Simple setup, operation, and maintenance Choice of two different centrifugal pumps Fluid level indicator RS232 communication and external water filter optional INCLUDED: The Polyscience LM61GX1A110C LM6 Benchtop Chiller , -10°C to 30°C, 560W; 120V includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - 2 Year Manufacturer's Warranty

$4,099.00 ex VAT
United States
chillers, heating & cooling
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V-cover
Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V

Polyscience CA02A1T1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VACFe (more)atures - Large, full-color touchscreen display with intuitive interface and support for five different languages - Compact, portable design takes up less floor space - Cooling at ambient temperatures as high as 30°C - Choice of pumps and compressor size - DynamicFilter™ self-cleaning filter system - Front fill reservoir - Liquid level monitoring to prevent pump failure - Ultraviolet anti-biological light system - User-adjustable temperature, pressure, and flow rate alarms - Heat up to 70°C, without additional options; ideal for applications, such as lasers, that must be brought to a temperature above ambient before operation can begin - External temperature tracking and communications capability (optional) - Cool Command™, WhisperCool® Your browser does not support iframes.*3D model is solely for visualization and may not depict the actual appearance of your product. DuraChill® is preprogrammed to change its own air filter once a month for a two year period and can be adjusted to suit your operating environment. DuraChill Chillers offer a conveniently located front fill reservoir. You no longer have to go to the back of the chiller top open to fill the reservoir. These high-performance chillers utilize Polyscience's exclusive patent-pending Whispercool noise reduction system. Stableand reliable cooling for many common heat removal applications, including laseretching, AA furnaces, ICP, rotary evaporators, vacuum systems, reactionvessels, plasma etching, and condenser cooling. Click Here to View Product Video INCLUDED: The Polyscience CA02A1T1-41AA1N Durachill Chiller , -10°C to 70°C, 850W; 120V is brand-new . Includes: - Power Cord - Operator's Guide - Manufacturer's Documentation - Full 2 Year Parts and Labor Warranty - Two sets of Inlet/Outlet Adapters: ½ inch male NPT x ½ inch hose barb and ½ inch male NPT x 5/8 inch hose barb Polyscience CA02A1P1-41AA1N Durachill Chiller with Turbine Pump, -10 to 70°C, 700 to 2900W, 120VAC Specifications Part NumberCA02A1T1-41AA1NCooling Capacity @ 20°C0.85 kWCooling Capacity @ 10°C0.6 kWCooling Capacity @ 0°C0.4 kWFluid Temperature Range-10 to 70°C / 14 to 158°FTemperature Stability±0.1°CTemperature Display Units°C or °FDisplayable Pressure UnitsPSI or kPaPump Inlet and Outlet½ inch female NPTConnectivityRS-232, USB Serial Port Emulation, USB TMC, Dry Contact On/Off/StatusPump Pressure Range20 to 90 psi / 138 to 689 kPaMaximum Pump Flow Rate3.5 gpm / 13.2 lpmPower Requirements120V, 60Hz, 13.7AShipping Weight169 lbs / 76.7 kgShipping Dimensions33 x 22 x 33 in / 84 x 56 x 84 cmComparison of ModelsSpecificationPolyscience CA02A1P1-41AA1NPolyscience CA02A1T1-41AA1NPolyscience CA03A1P1-41AA1NPolyscience CA03A1T1-41AA1NPolyscience CA05A1P1-41AA1NPolyscience CA05A1T1-41AA1NPolyscience CA10A3P2-41AA1NPolyscience CA10A3T1-41AA1NCooling Capacity @ 20°C (kW)0.85 kW0.85 kW1.4 kW1.4 kW1.74 kW1.74 kW2.9 kW2.9 kWCooling Capacity @ 10°C (kW)0.6 kW0.6 kW0.99 kW0.99 kW1.29 kW1.29 kW1.93 kW1.93 kWCooling Capacity @ 0°C (kW)0.4 kW0.4 kW0.53 kW0.53 kW0.77 kW0.77 kW1.0 kW1.0 kWFluid Temperature Range (°C/°F)-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°F-10 to 70°C / 14 to 158°FPump Pressure Range (psi/kPa)45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa45 to 100 psi / 310 to 689 kPa20 to 90 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPa20 to 100 psi / 138 to 689 kPaMaximum Pump Flow Rate (gpm/lpm)2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm2.6 gpm / 9.8 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpm3.5 gpm / 13.2 lpmPower Requirements (Voltage/Hz)120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz120V, 60Hz230V, 60Hz230V, 60Hz.comparison-table tr td:nth-child(3) { background-color: #fffacd; }

$6,982.00 ex VAT
United States
chillers, heating & cooling
People are watching right now:
LAUDA Varioshake VS 8 B digital reciprocating shaker-cover
LAUDA Varioshake VS 8 B digital reciprocating shaker

Varioshake shakers The silent LAUDA shakers are available in a large number of variations and shake  (more)each sample evenly, such as 15ml and 50ml tubes, Erlenmeyer flasks and containers. They can be used for a large number of purposes, thanks to a wide range of accessories. Areas of application: - Biology and microbiology - Medical diagnostics - Analytical laboratories - Test institutes, universities and research facilities - Quality Assurance Laboratories Reliable and durable with new LAUDA design The shakers are the laboratory's trusty 'workhorse'. LAUDA agitators are produced with 'GFL technology' and are synonymous with the highest quality, reliability and durability. Their robust, low-wear mechanical system ensures extremely smooth operation and reliable continuous service. Furthermore, thanks to the new LAUDA design, the shakers adapt to any laboratory environment, thanks to their small footprint and are extremely easy to use. Control panel: analog or digital The LAUDA Varioshake VS 8 OE and BE, with analog rotary controllers, allow adjustment of speed and operating time. Digitally controlled agitators provide an extended timer range, start / stop function and provide the ability to save the latest operating parameters. Shaker tray, test tube holder, Erlenmeyer flask clamp easy to install in seconds. All available as an accessory. Turn on, set the shaking frequency, set the running time, done. Highest quality materials: daily use for years without problems.

€1,383.00 ex VAT
€1,645.77 incl. VAT if applicable
Italy
shakers
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: Solvent tray Vacuum degasser: G1322A Vacuum degasser: The Agilent 1100 HPLC Degasse (more)r features a 4-channel vacuum container, including four tubular plastic membranes, and a vacuum pump. This degasser has a maximum flow rate of 0-10ml/min flow rate per channel and 5-10ml/min at reduced degassing performance. Quaternary pump: Hydraulic system: Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments Flow range: 0.2 – 10.0 ml/min Flow precision: < 0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature Flow accuracy: ± 1% or 10 µl/min whatever is greater Pressure: Operating range 0 – 400 bar up to 5 ml/min, 0 – 200 bar up to 10 ml/min Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel Gradient formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure Composition Range: 0 – 95 % or 5 – 100 %, user selectable Composition Precision: < 0.2 % RSD, at 0.2 and 1 ml/min Autosampler thermostat: Temperature range: setable from 4°C to 40°C in 1°C increments Temperature accuracy (at ambient temperatures < 25 °C and humidity < 50%): – 1°C to + 4°C at a setpoint of 4°C Temperature accuracy (at ambient temperatures > 25 °C and/or humidity > 50%): – 1°C to + 5°C at a setpoint of 4°C Standard autosampler: Pressure: Operating range 0 – 400 bar GLP features: Early maintenance feedback (EMF), electronic records of maintenance and errors Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.1 – 100 µl in 0.1 µl increments Replicate injections: 1 – 99 from one vial Precision: <0.25% RSD from 5 – 100 µl, <1% RSD 1 – 5 µl Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial Carryover: Typically <0.1% Sample viscosity range: 0.2 – 50 cp Replicate injections per vial: 1 – 99 Sample capacity 100 x 2 ml vials in 1 tray Injection cycle time: Typically 50 s depending on draw speed and injection volume Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.

€14,999.00 ex VAT
Netherlands
hplc systems
Radwag CY10.6.D2.K.M3 Multifunctional Scale-cover
Radwag CY10.6.D2.K.M3 Multifunctional Scale

CY10 scale&rsquo;s multi functions The CY10 series multifuncional scale is designed for fast, accura (more)te and repeatable weight determination. It comes with an advanced PUE CY10 terminal, and that means working comfort with a 10-inch high-resolution display with a smooth and intuitive interface. Software for special tasks Thanks to the terminal advanced software, the CY10 multifuncional scale: Cooperates with up to 2 weighing platforms Continuously updates all statistical data after the next measurement is entered into the balance&rsquo;s memory &ndash; either globally (regardless of the weighed commodity) or separately for each weighed commodity selected from the database Has a Tare mode expanded to include End-product issue mode capability Works with RFID tags* (accessing personal data as well as marking specific goods or recipe ingredients in the database). Multifunctional scale, including labelling scale If you need a labeling scale, the CY10 is the perfect solution. With a terminal that: Cooperates with the computer program Label Editor R02 Is compatible with ZEBRA label printers Supports single labels, bulk labels and bulk from bulk labels Allows import/ export of label designs using a pendrive Enables you to assign labels to goods or customers and print a global label The CY10 series multifuncional scale can operate as a labeling scale. Light or dark? Which color theme will you set on your CY10 balance? Both are user-friendly and clear, but we are curious which one you like more. Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13,56 MHz

€1,922.00 ex VAT
Poland
platform scales
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]