Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Location
- United States
This item is
State of item
new
Categories

IKA VACSTAR Lite Vacuum Pump

item image

Description from the supplier

IKA VACSTAR Lite Vacuum Pump


Final Pressure Without Gas Ballast
9 mbar
Pump Rate Max. (50/60Hz)
16.67 l/min
Input Pressure
10 to 1,030 mbar

  • Speed-controlled, 2-cylinder vacuum pump for universal dry and oil-free vacuum applications
  • Chemically resistant membranes with ultimate vacuum pressure of 9 mbar
  • Compact design saves bench space and allows placement behind other lab equipment
  • Seamless communication with vacuum controllers and circulators for synchronized processes
  • Integrated valve cleaning function extends system life and reduces maintenance costs
  • Quiet operation with a noise level of 54 dB(A) for a more comfortable lab environment
  • USB-C interface and analog input for enhanced connectivity and control
  • Lightweight and durable with aluminum-cast and thermoplastic polymer housing
  • Recommended use of the VSE 1 emission condenser for safety and clean ambient air


The VACSTAR lite is a versatile, speed-controlled, 2-cylinder vacuum pump designed for universal dry and oil-free vacuum applications. Featuring chemically resistant membranes and an ultimate vacuum pressure of 9 mbar, it is well-suited for a wide range of laboratory tasks. Whether used with rotary evaporators, laboratory reactors, temperature chambers, centrifuges, or classic Schlenk lines and filtration systems, the VACSTAR lite delivers high operating efficiency and flexibility. Its robust construction ensures long-term reliability with minimal maintenance, making it an indispensable tool for standard laboratory workflows.

  • Vacuum Hose, 1m
  • Silencer
  • Connecting Cable
  • Warranty Card
  • Power Cord
  • Operator's Manual
  • Manufacturer's Documentation
  • 2 Year Manufacturer's Warranty
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
KNF SC 920 Vacuum Pump System-cover
KNF SC 920 Vacuum Pump System

Deliver precise vacuum and offer widely diverse control functions for a huge range of applications i (more)n the laboratory. The intuitive user guidance on the hand terminal ensures ease of operation; the process parameters can be entered over a touchscreen and a rotation knob. Ajustment capabilities: Units of measurement The operating language The operating mode Parameters, such as the setpoint pressure or suction capacity of the system direct over rotation knob. Depending on the selected operating mode, the graphic display of the hand terminal then indicates the respective process variables. The user can intervene in the ongoing process at any time with the hand terminal and its integrated touchscreen and rotating knob. The hand terminal can be located via vacuum pump system (paging); the hand terminal will answer with a signal tone. Four operating modes: Evacuate – The vacuum pump system evacuates a vacuum chamber with adjustable pump capacity. Pressure control – The vacuum pump system controls the system pressure to the set value (constant pressure). Automatic – The vacuum pump system automatically finds the vapour pressure of the sample and adjusts the process pressure accordingly. Individual pressure function – The vacuum pump system controls the process according to a user-defined pressure curve. The setpoint pressure and the opening and closing of the coolant valve (accessory) on the high-performance condenser can be easily entered for a range of set times. A repeat function allows successive repetitions of the programmed pressure curve.At any time during an active process, you can switch to manual process control. Functions for Evacuate and Pressure control will be available simultaneously. Flow rate (at atm. pressure): 1.26 m³/h Flow rate (at atm. pressure): 21 l/min Ultimate vacuum (< 5.0 with gas ballast valve in use): 2.0 mbar abs. Operating pressure (max.): 0.5 bar (rel.) Dimensions (WxHxD): 366 x 423 x 294 mm Weight: 15 kg

€3,499.00 ex VAT
Netherlands
vacuum pumps, pumps liquid & other
Edwards nXDS20iC Dry Scroll Pump-cover
Edwards nXDS20iC Dry Scroll Pump

Edwards nXDS20iC Dry Scroll PumpFeatures - Bearing shield ensures separation between process gases a (more)nd bearing lubrication to ensure clean vacuum and no possibility of contamination. - Smart motor drive means consistent performance globally, pump overload protection and remote start/stop capability. - High flow gas ballast feature allows pumping of vapours including water vapour at up to 240 gh-1 - Simple single sided scroll design allows maintenance to be done in minutes for low cost of ownership and maximum up-time. - Enhanced versions offer up to 20% lower peak power requirements during initial pump down. The nXDS allows a wide range of control and communication options The nXDS comes as standard with a manual, easy to use, gas ballast port A perfect companion for your turbomolecular pump With exceptional pumping capability, ultimate vacuum performance and state-of-the-art design features Edwards nXDS is the best performing pump in its class.nXDS improves on legacy XDS pumps by offering increased pumping speeds, combined with lower ultimate pressures, lower power consumption and lower noise - up to 20 times quieter than other pumps. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. nXDS pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimised pumping performance globally. The Edwards nXDS20iC features Chemraz internal valves and stainlesssteel fittings for extra protection from the pumped media. The ‘C’ series isbetter designed for more aggressive applications as opposed to the standardseries. Click Here to View Product Video INCLUDED: The Edwards nXDS20iC Dry Scroll Pump includes: - 1 Year Full Parts and Labor Warranty - Power Cord - Manufacturer's Documentation - Operator's Manual Edwards nXDS20iC Dry Scroll Pump Technical SpecificationsNominal rotational speed1800 rpmDisplacement28.0 m3h-1 / 16.5 ft3min-1Peak pumping speed22.0 m3h-1 / 13.0 ft3min-1Ultimate vacuum (total pressure)0.030 mbar / 0.022 TorrMinimum standby rotational speed1200 rpmSpeed control resolution (percentage of full rotation speed)1%Pumping speed at minimum rotational speed10Maximum continuous inlet pressure50 mbarMotor power 1-ph260 WPower connector 1-phIEC EN60320 C13Recommended fuse10A, 250Vac rmsWeight25.6 kg / 56 lbInlet flangeNW25Exhaust flangeNW25Noise level52 dB(A)Vibration at inlet flange&lt; 4.5 mms-1 (rms)Leak tightness (static)&lt; 1x10-6 mbar ls-1Operating temperature range10 to 40 °C / 41 to 104 °FElectrical Supply115/230VComparison of ModelsParameterEdwards nXDS6iCEdwards nXDS10iCEdwards nXDS15iCEdwards nXDS20iCNominal rotational speed (rpm)1800180018001800Displacement (m³h⁻¹ / ft³min⁻¹)6.2 / 3.612.7 / 7.517.1 / 10.128.0 / 16.5Peak pumping speed (m³h⁻¹ / ft³min⁻¹)6.2 / 3.611.4 / 6.715.1 / 8.922.0 / 13.0Ultimate vacuum (total pressure) (mbar / Torr)0.020 / 0.0150.007 / 0.0050.007 / 0.0050.030 / 0.022Weight (kg / lb)26.2 / 5825.8 / 5725.2 / 5625.6 / 56Inlet flangeNW25NW25NW25NW25Noise level (dB(A))52525252Operating temperature range (°C / °F)10 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 10410 to 40 / 41 to 104Electrical Supply115/230V115/230V115/230V115/230V.comparison-table tr td:nth-child(5) { background-color: #fffacd; }

$9,865.00 ex VAT
United States
pumps liquid & other
People are watching right now:
Radwag MA 200/1.5Y.NS Moisture Analyzer-cover
Radwag MA 200/1.5Y.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content &ndash; of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y Moisture Analyzer is 160&deg;C. How Do I Finish the Drying? In 4 Ways The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer&rsquo;s accuracy and sensitivity. 10-Inch Display Bigger screen &ndash; 10&rsquo;&rsquo; &ndash; means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light &ndash; an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note &ndash; Note Down Your Conclusions It&rsquo;s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€7,228.00 ex VAT
Poland
balances, moisture analysers
Motic Panthera TEC POL (Digital)-cover
Motic Panthera TEC POL (Digital)

Motic Panthera TEC POL (Digital) Features - UC Plan Achromat objectives (strain-free) for FOV 22mm - (more) Transmitted and transmitted/ incident stand options - Transmitted light: LED/HAL light source interchangeable - Integrated focusable/ centerable Bertrand lens - Motic LightTracer: Coded nosepiece &amp; Digital light intensity knob The Panthera TEC POL series fills a last gap in the Panthera family: Polarization microscopes for all material sciences, ready to handle transparent samples like fibers and foils with their inherent birefringence. The Incident light models for opaque materials work out the specific reflectivity (bireflection) of flat surfaces. To extend the application fields, all microscopes carry an intermediate tube with Bertrand lens to analyze the crystal structure and interference figures of gems, precious stones and minerals.INCLUDED: The Motic Panthera TEC POL (Digital) includes: - 4X/0.1 (WD 30.5mm) Objective - 10X/0.25 (WD 17.4mm) Objective - 40X/0.65/S (WD 0.6mm) Objective - 60X/0.8/S (WD 0.35mm) Objective - Widefield UC-WF10X/22mm with Diopter Adjustment - Dust Cover - Power Cord - Allen Key - Blue Filter - Halogen Bulb - Adjustable Key for Nosepiece - Interference Color Chart - Screws for Metal Extension Support - Operator's Guide Motic Panthera TEC POL (Digital) SpecificationsOptical systemColour Corrected Infinity Optical System (CCIS®)Observation tubeBinocular head, Siedentopf type with built-in digital cameraSensor typeCMOSSensor size1/2.5"Capture resolution5MP (2592x1944)Live display mode (through Wi-Fi)1920x1080 (Full HD)Live display mode (through ethernet)1280x720, 1920x1080 (Full HD)Live display mode (through HDMI)1280x720, 1920x1080 (Full HD)Inclination25º inclinedTrinocular light split-Interpupillary distance48-75mmDiopter adjustmentOn both eyepieces, +/- 4 diopterEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentNosepieceReversed quintuple, coded with single centering holesIntermediate BodyRotatable analyzer 360º, Bertrand lens and slot for compensatorsObjective classificationCCIS® UC Plan Achromatic (strain-free), DINObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)Objective mounting threadW 4/5"x1/36" (RMS standard)StageCircular rotating 360º, lockableStage sizeØ160mmTravel range X&amp;Y1º increments, 0.1º vernier scaleCondenserFocusable and centerable Achromat Swing-out Abbe condenser N.A. 0.90/0.13 (strain-free) and rotatable polarizerDiaphragmIris diaphragmFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentFine focus precision2µmFocusing stroke25mmUpper limit stopUpper limit stop preset but adjustableFilter holderOn top of the illuminator with fixing capTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlIllumination interchangeabilityHalogen/LED and LED color temperature interchangeabilityIllumination featuresMotic LightTracer: Light memory, sleep mode (auto on-off), nosepiece LED light intensity and mode indicatorTransformerInternalPower supply110-240V (CE)Other featuresUSB 2.0 for external camera powerDimensions LxWxH410x300x395mmNet weight9.9kgComparison of ModelsSpecificationPanthera TEC POL (Binocular)Panthera TEC POL (Digital)Panthera TEC POL (Trinocular)Optical systemCCISCCISCCISObservation tubeBinocular head, Siedentopf typeBinocular head, Siedentopf type with built-in digital cameraTrinocular head, Siedentopf typeEyepiecesWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentWidefield UC-WF10X/22mm with diopter adjustmentObjectives4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)4X/0.1 (WD 30.5mm), 10X/0.25 (WD 17.4mm), 40X/0.65/S (WD 0.6mm), 60X/0.8/S (WD 0.35mm)StageCircular rotating 360º, lockableCircular rotating 360º, lockableCircular rotating 360º, lockableStage sizeØ160mmØ160mmØ160mmTravel range X&amp;Y1º increments, 0.1º vernier scale1º increments, 0.1º vernier scale1º increments, 0.1º vernier scaleFocus mechanismCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentCoaxial coarse and fine focusing system with tension adjustmentTransmitted illuminationKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity controlKoehler Quartz halogen 6V/30W with intensity control.comparison-table tr td:nth-child(3) { background-color: #fffacd; }DownloadsTechnical Specification Download

$4,969.00 ex VAT
United States
general laboratory equipment other
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]