Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Radwag
Model
AP-12.5Y Automatic Device for Multichannel Pipette Calibration
Supplier
Radwag
Location
Radom - Poland
Price
€26,933.00 
(ex. VAT)
This item is
for sale
State of item
new
Categories

Radwag AP-12.5Y Automatic Device for Multichannel Pipette Calibration

Radwag€26,933.00 (ex VAT)
item image

Description by the supplier

The AP-12.5Y is designed to calibrate multichannel pipettes starting at 10 μl. The device features a readability [d] of 0.01 mg and can calibrate up to 12-channel fixed-volume and variable-volume pipettes.


Because the pipette calibration on the AP-12.5Y is fully automatic, it is four times faster. The calibration procedure for a 12-channel pipette takes less than 20 minutes, not six hours, on this instrument.


When purchasing the AP-12.5Y, you get:


two calibrated sensors: THB S and THB W,


two weighing pans: standard, and for balance test and calibration,


two pumps: a single-channel pump and a four-channel pump


The ergonomic design of the AP-12.5Y makes it possible to empty weighing vessels, and their overfilling is signalled by Ambient Light. When calibrating a multichannel pipette, a

four-channel pump is used to simultaneously remove water from four vessels, greatly reducing the time required for pipette calibration.


After emptying a 12-channel pipette, the AP-12.5Y checks all channels in a single cycle. In addition to a database of pipette calibration reports, the AP-12.5Y includes a database of pipettes that is editable and contains maximum permissible error values according to ISO 8655. The report database, in turn, contains measurements and error values calculated for individual points and volumes. The user determines the format and content of the reports.


The AP-12.5Y monitors the ambient conditions using calibrated sensors: THB S (ambient conditions measurement) and THB W (liquid temperature measurement), in accordance with ISO 8655. To calibrate the device with mass standards, the weighing pan must be replaced with a pan dedicated to checking and calibrating the balance (both are included in the standard equipment).


The AP-12.5Y can calibrate not only 12-channel pipettes, but also single-channel pipettes.

Product details
FunctionsAutotest, Statistics, IR sensors, GLP Procedures, Pipettes Calibration, Air density correction, Ambient conditions monitoring, Statistical Quality Control, ALIBI Memory
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Radwag F2 Mass Standard - Stainless Steel Wire - 2 mg-cover
Radwag F2 Mass Standard - Stainless Steel Wire - 2 mg

F2-class mass standards represent an impressive level of precision in mass measurement. Classified a (more)s metrology grade F2, they are recognized as top-quality tools suited for advanced applications where precision is a key element. F2 mass standard: stainless steel wire Nominal value: 2 mg Material: stainless steel Exceptional Measurement Precision F2 class mass standards feature excellent measurement precision achieved through stringent standards for allowable deviation from actual weight. Stability under Dynamic Conditions An important feature of F2-class mass standards is their ability to maintain measurement stability even under dynamic measurement conditions. They are designed to cope with a variety of factors that affect measurement precision. Calibration at the Highest Level The calibration process of F2-class mass standards adheres to the most stringent norms and standards. This makes the standards of this class recognized as tools with the highest degree of accuracy, complying with international requirements. Use of Materials with Outstanding Properties F2 class mass standards are often constructed from materials with outstanding physical properties. This ensures not only excellent precision, but also exceptional durability. Application 1. Scientific Research at the Highest Level In scientific research, especially in fields that require the utmost precision, such as nuclear physics or astrophysics, F2 class mass standards are indispensable. 2. Metrology Industry In metrology laboratories engaged in testing and maintaining the most advanced measurement standards, F2 class standards are indispensable working tools. 3. High-Precision Testing Laboratories In laboratories specializing in research requiring the highest precision, such as forensic laboratories and materials testing, F2 class mass standards are essential. 4. Aerospace Industry In the precision mass measurements required in the aerospace industry, F2 class standards provide reliability and excellence. F2 class mass standards are the symbol of the highest precision in the field of mass measurement. Their use is crucial in the most advanced fields of science, industry and research.

€34.00 ex VAT
Poland
mass standards
Radwag E1 Mass Standard - Stainless Steel Wire -500 mg-cover
Radwag E1 Mass Standard - Stainless Steel Wire -500 mg

E1-class mass standards are the elite in the world of metrology, because standards of this class rep (more)resent the highest level of precision and accuracy in mass measurement. The E1 classification is one of the most stringent standards that standards must meet in order to be considered the most advanced and trustworthy measurement tools. E1 - class standard: stainless steel wire Nominal value: 500 mg Material: stainless steel What Are the Characteristics of the E1 Class? Highest Precision - The allowable deviation from the actual weight is minimal, making standards of this class ideal for applications where every gram matters. Stability and Repeatability - This guarantees a consistent level of accuracy over the long term. Accurate Calibration - Standards of this class must be regularly compared with other standards of known mass to confirm their measurement accuracy. Materials with Unique Properties - E1 class mass standards are often made of materials with exceptional physical properties, which makes them stable and resistant to changes in environmental conditions. Application 1. Analytical Laboratories In analytical laboratories where accurate measurements are crucial, E1 class mass standards are used to calibrate balances with the highest precision. 2. Pharmaceutical Industry In drug manufacturing, where even the slightest deviation from the standard affects quality, E1 class mass standards are irreplaceable. 3. Scientific Research In scientific research, especially in areas requiring the highest precision, such as physics or chemistry, E1 class mass standards are used to ensure reliable results. 4. Metrology Industry In metrology laboratories where research on E1 class mass standards alone is carried out, E1 class standards are the standard of excellence. Class E1 mass standards are not only measuring tools, but also a symbol of metrological excellence. Their use affects the quality of measurements in various areas of life because they provide precision that can be relied upon. They are a key element in the world of mass measurement, shaping standards and raising the bar for all measurement tools.

€71.00 ex VAT
Poland
mass standards
Radwag XA 220.5Y Analytical Balance-cover
Radwag XA 220.5Y Analytical Balance

Do you need a balance that not only determines weight with impressive accuracy, but also performs a  (more)digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of balances: Digital Weighing Auditor Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the balance will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – An Innovative Way for the Balance to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the balance on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. Smart Min Weight The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. - Full data security - Electronic signatures - Validations - Electronic records - Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. Two-point adjustment Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€5,174.00 ex VAT
Poland
analytical balances, balances, scales
Radwag PS 8100.R2.M Precision Balance-cover
Radwag PS 8100.R2.M Precision Balance

PS.R2 series balances represent a new standard of precision balances. They feature a new, readable L (more)CD display which allows a clearer presentation of the weighing result. Besides, the display has a new text information line allowing to show additional messages and data, e.g. product name or tare value. Communication interfaces New PS.R2 balances, like previously designed PS series balances, have pans in two possible dimensions: 128x128 mm or 195x195 mm balances with a smaller pan have a draft shield. The balance precision and the measurement accuracy is assured by automatic internal adjustment, which takes into consideration temperature changes and time flow. PS.R2 balances feature several communication interfaces: 2 x RS 232, type A USB, type B USB and optional Wireless Connection. The balance may cooperate with computer by means of USB interface supposing a supplementary software has been installed (respective driver). The said driver may be downloaded from RADWAG website – SOFTWARE link or SUPPORT section. The housing is made of plastic, and the pan is made of stainless steel. The balances have a possibility to weigh products out of the pan (under-pan weighing) - the load hangs under the pan. Databases in R Series Balances The information system is based on 5 databases, which allows for several users to work with several products databases, and the registered weighing results can be subject to further analysis. The data is registered in 5 databases: users (up to 10 users), products (up to 1000 products), weighments (up to 5000 weighments), tares (up to 100 tares), ALIBI memory (up to 100 000 weighments). Quick access to information There is two directions data exchange within the system thanks to a quick USB interface. New balances allow to import and export databases using USB pen drives. Direct access to functions and databases is possible from the level of keyboard. Database - a direct access to databasis Function - a direct access to the basic functions F1 do F4 - programmable function and navigation keys on the menu ALIBI memory The used ALIBI memory is a data secure area and allows to record up to 100 000 weighment records. It ensures security of constant data register in the long time period. Under-pan weighing Weighing instruments purchased after 15th February 2023 will allow under-pan weighing at any time after the purchase. All you need to do is just to order a dedicated hook. THBR 2.0 System Cooperation with THBR 2.0 System for ambient conditions monitoring.

€810.00 ex VAT
Poland
balances, precision balances
Radwag MA 210.X7.A.NS Moisture Analyzer-cover
Radwag MA 210.X7.A.NS Moisture Analyzer

MA X7.A moisture analyzers are hi-tech measuring instruments intended for quick determination of rel (more)ative moisture content, dry mass content and other parameters in samples of different substances. MA.X7.A series is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors. Such solution allows: Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing. Removing any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity. Achieving high repeatability of opening and closing the drying chamber. Enhancing drying process automation. Enhancing safety of operation by eliminating contact with hot components of drying chamber. Improving operation ergonomics. MA.X7.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product. Highlights of X7 Series moisture analyzers: Automatic opening and closing of the drying chamber 7” capacitive colour touchpad Modern interface Uncomplicated, intuitive operation Programmable display Drying profiles (standard, mild, step, fast) GLP/GMP printouts-reports Repeatable and customized applications Work optimization due to the use of halogen lamps Capacity and temperature MA.X7.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature). An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather. Databases: Information system of X7 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis. Collected data is registered in 8 databases: Products (up to 5000 products) Users (up to 100 users) Packaging (up to 100 packagings) Customers (up to 1000 customers) Drying programs (up to 200 drying programs) Drying process reports (up to 5000 drying process reports) Ambient conditions (up to 10000 records) Weighings (up to 50000 records) The results The results obtained using the moisture analyzer (the final result of the drying process): % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage, % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated, % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process, g – the sample mass after drying. Interfaces USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer. Remote access to the moisture analyzer allows for online data management. Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

€1,936.00 ex VAT
Poland
balances, moisture analysers
People are watching right now:
Radwag E2 Mass Standard - Stainless Steel Wire -100 mg-cover
Radwag E2 Mass Standard - Stainless Steel Wire -100 mg

E2-class mass standards represent an exceptional standard of precision in mass measurement. Classed  (more)as E2 metrology class, they are characterized not only by their high accuracy, but also by their versatility for use in laboratories, industry or scientific research. E2 class standard: stainless steel wire Nominal value: 100 mg Material: stainless steel High Precision of measurements The mass standard is the foundation of accurate mass measurement, as it affects the quality and reliability of results in many areas. Its role in maintaining uniformity and in meeting measurement standards is crucial, making the mass standard an indispensable metrology component. Stability over Time An important feature of E2 class mass standards is their ability to maintain measurement stability over the long term. It is this stability that makes standards of this class highly valued in laboratories and industry. Calibration and Strict Quality Control Systematic calibration is a key element in maintaining E2 class standards. This process involves comparing the mass standard with other standards of known mass to confirm and maintain measurement accuracy. Versatility of Applications E2 class mass standards are designed for a wide variety of applications. They can be used in analytical laboratories, the pharmaceutical industry, scientific research or other areas requiring precise mass measurements. Applications 1. Analytical Laboratories In analytical laboratories, where precise and repeatable measurements are crucial, E2 class mass standards find their wide application. 2. Pharma Industry In drug manufacturing, where quality control plays a key role, E2 class mass standards are indispensable in the calibration process of balances. 3. Scientific Research In scientific research, especially in areas requiring the utmost precision, E2 class mass standards are an indispensable tool for obtaining reliable results. 4. Metrology Industry In metrology laboratories, E2 class standards provide a reference point for evaluating and testing other measurement standards. E2 class standards are synonymous with excellence in mass measurement. Their versatility and high precision make them an indispensable tool in laboratories around the world and improve the quality and reliability of mass measurement results.

€59.00 ex VAT
Poland
mass standards
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]