Boekel Scientific 270800 Mixer, Heat/Cool Thermal Mixer II w/270811 Block

Marshall Scientific$3,371.00 (ex VAT)
item image

Description by the supplier

Boekel Scientific 270800 Mixer, Heat/Cool Thermal Mixer II w/270811 BlockThe Boekel Scientific 270800 Mixer,Heat/Cool Thermal Mixer II w/270811 Block has a large intuitive touch screen,interchangeable auto-recognized blocks to fit most laboratory consumables,multiple modes for increased process performance and a large and accuratetemperature and mixing range.

Large Color Touch Screen

Programmable heating, cooling, and mixing sequences

Intuitive navigation and programming

Interchangeable, auto-recognized blocks

Up to five independent programmable steps

Super accurate calibration

Steps can be repeated in the repeat mode

Easy to remove heating/cooling blocks

Better performance than competitor units

Supplied with 270811 Block

Blocks 270818, 270819 and 270820 include a lid


ApplicationsExtraction, expression, labeling, cloning,purification and analysis of proteins, DNA, Plasmids, RNA, from gels, magneticbeads, tissue, or biological samples

Stability testing

Isolating RNA

Protein preparation

DNA/RNA extraction


INCLUDED:

The Boekel Scientific 270800 Mixer, Heat/Cool Thermal Mixer II w/270811 Block includes:

- Thermal Mixer Block, 24 x 1.5ml Tubes

- Power Cord

- Operator's Guide

- Manufacturer's Documentation

- 2 Year Manufacturer's Warranty

Product details
Model #270800
Capacity0.5ml tubes to 50ml tubes (block dependent)
Block Included with Unit1.5ml x 24 tubes
Dimensions W x D x H (in)9 x 13 x 5.3 (23 x 33 x 13.5cm)
Speed Range (rpm)0, 250 to 3000
Speed Setting Increments (rpm)50
Timer0 - 99 Hours 59 Min 59 seconds / ∞
Operation Temperature Range10°C to 30°C
Temperature Range15°C below ambient to 100°C
Heat Up Rate (Selectable)5°C/Min, 2°C/Min, 1°C/Min
Cooling Rate (Fixed) Above Ambient Below Ambient3°C/Min - 1.5°C/Min
Temperature Accuracy 20°C to 40°C < 20°C and >40°C+/- 0.2°C +/- 0.5°C
Temperature Uniformity 20°C to 40°C±0.3°C
Temperature Setting±0.1°C / 1.0°C to 99°C
CalibrationYes - Easy 4 point
Electrical ApprovalPower pack UL, UL Canada, and CE approved
Shipping Weight25 lbs. / 11.34 kg
About QuestPair

QuestPair matches professionals in research and industry with manufacturers, suppliers and resellers of scientific products. Companies and organisations can easily sign up for an account and showcase their laboratory equipment and other products on the marketplace. It is possible to list both new as well as used equipment. QuestPair features a variety of equipment for the physical, chemical and life sciences such as spectrometers, balances, centrifuges, testing devices, medical devices, incubators, microfluidics kit, heaters, coolers and other specialist instruments.

Related items:
Ohaus VXMTAL Multi-Tube Vortex Mixer-cover
Ohaus VXMTAL Multi-Tube Vortex Mixer

Ohaus VXMTAL Multi-Tube Vortex Mixer Introducing the Ohaus VXMTAL - a state-of-the-art Multi-Tube Vo (more)rtex Mixer equipped with a pulsing mode on digital models to significantly enhance the vortexing action. It boasts a one-piece stainless steel housing design, ensuring easy clean-up and suitability for clean room environments.The Ohaus VXMTAL Mixer features a digital programmable pulse mode, enabling you to adjust the pulse-on/pulse-off times between 1-59 second intervals. This functionality promotes a vigorous mix, providing an optimal solution for precision-based work.For budget-conscious settings where exact speed/time isn't a necessity, our Analog Model offers a cost-effective alternative. It employs a variable speed microprocessor control to ensure consistent and uniform mixing action, with basic speed and time settings adjustable through intuitive 1 to 10 dial settings.The Ohaus VXMTAL Mixer excels in applications that require absolute accuracy and repeatability. Featuring a duty rating for continuous operation, this powerful tool provides efficient high-throughput mixing without the need for constant manual attention.Product Specifications: - Control: Analog - Duty Rating: Continuous - Orbit: 0.1 in (3.6 mm) - Speed Range: 1200 rpm – 2400 rpm - Power: 120V, 5A, 50/60Hz - Item Number: 30392164 The OHAUS Multi-Tube Vortexers come with interchangeable foam racks, ideal for vortexing tubes from 10 to 29 mm in diameter. These vortexers are securely fitted with strong suction cup feet to minimize motion and prevent sliding on your work surface.The digital models are furnished with independent LED displays for speed and time, allowing you to view both settings simultaneously. Our non-digital variable speed models serve as an economical alternative when exact speed control isn't a priority.Applications of the Ohaus VXMTAL Vortex Mixer include suspensions, genotyping, and high throughput DNA and RNA testing in clinical labs. The product comes with a stainless steel foam rack for (50) 12 mm diameter tubes, and interchangeable foam racks for vortexing tubes ranging from 10 - 29 mm in diameter. Operation is straightforward with a detachable 3-wire cord and plug included in the package.Experience the Ohaus quality and elevate your lab efficiency with the Ohaus VXMTAL Multi-Tube Vortex Mixer.INCLUDED: The Ohaus VXMTAL Multi-Tube Vortex Mixer includes: - Power Cord - Two Year Manufacturer's Warranty

$2,737.00 ex VAT
United States
mixers, vortex mixers
People are watching right now:
Agilent Series 1100 HPLC System-cover
Agilent Series 1100 HPLC System

System contains: 2 Solvent cabinets 2 Capillary pumps 1 Well-plate samplers 2 Autosampler thermostat (more)s 1 Thermostatted colomn compartment 1 Diode array detector 1 Handheld control module Vacuum degasser cel is missing in the vacuum degasser Capillary pump: Settable column flow range: 0.01 – 20 µl/min Recommended column flow range: 1 – 20 µl/min Column flow precision: < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) Optimum composition range: 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater Composition precision: < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting Delay volume: Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Pressure range: 20 to 400 bar (5880 psi) system pressure Compressibility compensation: User-selectable, based on mobile phase compressibility Recommended pH range: 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. Well-plate sampler: Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display Injection range: 0.01 – 8 µl in 0.01 µl increments Precision: Typically < 0.5 % RSD of peak areas from 5 – 40 µl, Typically < 1 % RSD from 1 – 5 µl, Typically < 3 % RSD from 0.2 – 1 µl Sample viscosity range: 0.2 – 5 cp Sample capacity: 2 × well-plates (MTP) + 10 × 2 ml vials, 100 x 2 ml in one tray, 40 x 2 ml in half tray Injection cycle time: Typically < 30 s using following standard conditions: Default draw speed: 4 µl/min, Default eject speed: 10 µl/min, Injection volume: 0.1 µl Carry-over: Typically < 0.05 % using the following conditions: Column: 150 x 0.5 mm Hypersil ODS, 3 µm Mobile phase: Water/Acetonitrile = 85/15 Column Flow rate: 13 µl/min Injection volume: 1 µl caffeine (=25ng caffeine), 1 µl water to test carryover. Outside wash of needle before injection: 20 sec with water using flush port Autosampler thermostat: Temperature range: setable from 4 °C to 40 °C in 1 ° increments Temperature accuracy at ambient temperatures < 25 °C and humidity < 50%: – 1°C to + 4 °C at a setpoint of 4 °C Temperature accuracy at ambient temperatures > 25 °C and/or humidity > 50%: – 1°C to + 5 °C at a setpoint of 4 °C Thermostatted colomn compartment: Temperature range: 10 degrees below ambient to 80 °C, up to 80 °C: flow rates up to 5 ml/min Temperature stability: ± 0.15 °C Temperature accuracy: ± 0.8 °C (± 0.5 °C With calibration) Column capacity: Three 30 cm Warm-up/cool-down time: 5 minutes from ambient to 40 °C, 10 minutes from 40 – 20 °C Dead volume: 3 µl Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other series module Safety and maintenance: Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Diode array detector: Detection type: 1024-element photodiode array Light source: Deuterium and tungsten lamps Wavelength range: 190 – 950 nm Short term noise (ASTM) Single and Multi-Wavelengt: ± 1 × 10-5 AU at 254 and 750 nm Drift: 2 × 10-3 AU/hr at 254 nm Linear absorbance range: > 2 AU (upper limit) Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter Wavelength bunching: 1 – 400 nm Programmable in steps of 1 nm Slit width: 1, 2, 4 , 8, 16 nm Programmable slit Diode width: < 1 nm Flow cells: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Control and data evaluation: Agilent ChemStation for LC Analog outputs: Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional Safety and maintenance: Extensive diagnostics, error detection and display through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. Handheld control module: The control module provides complete local control and monitoring of a single module or an entire Agilent series system. There is no data evaluation in the control module. The control module allows you to do a variety of HPLC tasks including automated sample preparation and injection, isocratic, gradient and multiple method analyses.

€9,999.00 ex VAT
Netherlands
hplc systems
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]