Polyscience P35N5A101B IP-35 Immersion Probe Cooler, -35°C to 40°C, 1004W; 120V

Marshall Scientific$2,861.00 (ex VAT)
item image

Description by the supplier

Polyscience P35N5A101B IP-35 Immersion Probe Cooler, 1.75 Rigid Coil Probe, -35 to +40C, 120V, 60Hz3D Visualization of the Polyscience Immersion Probe CoolerThe rendered image can be freely rotated in a full 360-degree view, allowing you to zoom in, pause, and explore every angle. For enhanced detail, the rendering can also be displayed in full-screen mode.

This 3D model is designed exclusively for visualization purposes and may not accurately represent the actual appearance of your product.

Your browser does not support iframes.


.rendering-block:nth-child(2) { width: 292px;}PolyScience Low Temperature Coolers enhance and simplify low-temperature laboratory work, providing rapid, low-cost cooling of liquids to temperatures as low as -100C. Typical applications include the cooling of exothermic reactions, vapor and solvent trapping, and impact testing. They’re also ideal for extending the temperature range of non-refrigerated circulators to below ambient and boosting the cooling capacity of refrigerated circulators.

Enhance and simplify your low-temperature laboratory work with a PolyScience Low Temperature Cooler. Available in both immersion probe and flow-through styles, they provide rapid, low-cost cooling of liquids to temperatures as low as -100C. Typical applications include the cooling of exothermic reactions, freeze point determinations, freeze drying, impact testing, lyphilization, and vapor and solvent trapping.


Features


Continuous cooling to temperatures as low as -100C

Designed to run at maximum cooling

An economical alternative to dry ice or liquid nitrogen

Excellent for trapping applications, freeze drying, and rapidly cooling small volumes of liquids


INCLUDED:

The Polyscience P35N5A101B IP-35 Immersion Probe Cooler, -35°C to 40°C, 1004W; 120V includes:

- Power Cord

- Operator's Guide

- Manufacturer's Documentation

- 2 Year Manufacturer's Warranty

Product details
DescriptionImmersion Probe-35, 1.75" Rigid Coil
Working Temperature Range C-35° to +40°
Temperature Control (C)Fixed at -35°
Part NumberP35N5A101B
Cooling Capacity @ -30C (W)106
Cooling Capacity @ -20C (W)152
Cooling Capacity @ -10C (W)253
Cooling Capacity @ 0C (W)421
Cooling Capacity @ +10C (W)703
Cooling Capacity @ +20C (W)1004
Cooling Capacity @ +30C (W)1205
Cooling Capacity @ +40C (W)1326
Electrical Requirements (VAC/Hz/Ph/A)120/60/1/5
About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
People are watching right now:
AREX 6 magnetic stirrer Velp-cover
AREX 6 magnetic stirrer Velp

AREX 6 by Velp Scientifica The central button activates the heating of the plate only after pressing (more) it, avoiding involuntary switching on. The safety icon informs the operator that the plate is at temperature, preventing possible burns. It will remain illuminated until the temperature is below 50°C. The knobs allow precise speed and temperature regulation with new ergonomics and greater sensitivity. CerAlTop™, High Resistance The CerAlTop™ plate, made of aluminum alloy covered with a ceramic layer, guarantees a homogeneous and fast heat transfer over the entire surface. Furthermore, the thin ceramic layer protects the straightener from scratches and chemicals. UNPRECEDENTED PERFORMANCE The brushless motor allows you to shake up to 20 liters at an adjustable speed from 30 to 1700 rpm. Thanks to the SpeedServo™ system, the speed is kept constant even when the viscosity varies. The Alnico magnet guarantees homogeneous agitation, even in the peripheral areas of the plate and a powerful magnetic coupling between motor and stir bar, a very important aspect when using accessories. MAXIMUM INSTRUMENT PROTECTION AREX 6 is an IP42 product designed to guarantee years of use and resistance in the laboratory. The structure and materials protect the internal parts of the instrument from possible damage. AREX 6 is guaranteed for 3 years. The silicone cover ensures further protection of the instrument from possible spills or splashes. ACCESSORIES OIL BATH AND HEATING MANTELS REPLACED WITH SPHERICAL CAPS The new Spherical Caps are the perfect solution for replacing oil baths and heating mantles. Furthermore, they adapt perfectly to both the 135 mm plate diameter and the shape of the tubes allowing a fast heat transfer from the plate to the tube. To increase protection and reduce thermal dispersion, VELP has designed the new PTFE Covers. GREATER VERSATILITY The MultiAlublock™ and the new MonoAlublock™ made of aluminium, are ideal for carrying out numerous stirring and heating analyses, reducing time and space in the laboratory. - MonoAlublock™ are the ideal solution for all those applications that require analysis in tubes of the same size. - MultiAlublock™ are modular and of different types to support various tube sizes. Thanks to their modularity, it is possible to choose the mix that best suits your needs

€425.00 ex VAT
€505.75 incl. VAT if applicable
Italy
stirrers
Radwag MA 200/1.5Y.IC.NS Moisture Analyzer-cover
Radwag MA 200/1.5Y.IC.NS Moisture Analyzer

Do you need a moisture analyzer that not only determines moisture or dry matter content with impress (more)ive accuracy, but also performs a digital audit, responds to your voice commands and sends you light messages? If so, learn about the functionality of the ELLIPSIS series of moisture analyzers: It Dries in 4 Ways The MA 5Y.IC Moisture Analyzer offers you four drying profiles: standard, mild, fast and step. The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content. The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather. You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent. The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally. What Drying Temperature Should I Set? The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally. The maximum drying temperature on the MA 5Y.IC Moisture Analyzer is 160°C. How Do I Finish the Drying? In 4 Ways The MA 5Y.IC Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined. Automatic mode You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end. Manual mode You terminate the measurement yourself by pressing the STOP button. Time-defined mode The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage! User-defined mode When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure. Digital Weighing Auditor Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity. 10-Inch Display Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history. Uncompromising User Verification For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these. Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User The light colour will tell you about status, process results, procedures, or alerts. Hotspot Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer. RFID ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user. Live Note – Note Down Your Conclusions It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note. Handy Library This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found. Widgets Prepared to display what you need most at any given moment. 21 CFR Part 11 Do you work in the pharmaceutical industry? Do you need a digital signature? We are offering the moisture analyzer which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11. Full data security Electronic signatures Validations Electronic records Audit trails Modbus TCP/IP is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds. * RFID ISO/IEC 14443 Type A, 13.56 MHz

€7,658.00 ex VAT
Poland
balances, moisture analysers
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]