Easily list your scientific equipment

Top suppliers for laboratory & industry

New and used instruments

Marketplace
Analytics
Brand
Ohaus
Supplier
Jointlab srl
Location
Milano - Italy
Price
€1,256.00 
(€1,494.64 incl. VAT*)*if applicable
This item is
for sale
State of item
new
Categories

Pioneer PX6202 Ohaus

Jointlab srl€1,256.00 
(€1,494.64 incl. VAT* )* - if applicable
item image

Description by the supplier

OPTIMIZED ACCURACY AND COST-EFFECTIVENESS

The Pioneer PX distinctively merges essential weighing capability with superior performance, delivering unparalleled precision and consistency suitable for laboratory, industrial, and educational settings. The PX model offers a cost-effective solution combined with smart, user-friendly design, boasting a two-line display for further data and USB and RS232 interfaces for communicative ease.


- Exceptional cost-to-value ratio

- Durably constructed, Pioneer boasts a metallic foundational structure, accompanied by stainless steel bottom plate and weighing basket.

- Upper echelon features as a norm: an additional line in the display for supplementary data or useful tips; an anti-static bar for proper earthing; and USB connectivity.


Additional Standard Features and Apparatus

A metallic base, plastic top casing, detachable stainless steel weighing basket, removable glass draft shield or side doors, real-time clock integrated with GLP/GMP data, integrated weigh below hook, safety bracket, lockable safety adjustment and protective covering, adjustable environmental filters and brightness settings according to user choice, automatic tare, automatic dim, adjustable span calibration points as per user, menu for software lockout and reset, user-preferred communication settings and options, user-selected data printout, user-specific project and user ID, software overload/underload indicator, stability indicator, and functionality in 11 languages.


AVAILABLE MODELS


InCal= Internal calibration.

ExCal= External calibration

*Models compliant with CE standards


STANDARD FUNCTIONS FOR EXPERT USAGE

- The Real-Time Clock (RTC) feature ensures time accuracy persistently, regardless of power failures. The GLP/GMP data output function assists in recording the sample name, project, user, and balance IDs, aiding in fulfilling traceability and regulatory norms. Password protection minimizes the probability of inadvertent or unauthorized modifications.

- The Pioneer PX scale, facilitated with USB and RS232 connectivity ports, simplifies communication with a PC, impact printer, or a Zebra label printer.

- Sustainability-focused features: Auto power-off and alternative brightness adjustments conserve energy when the scale is inactive.

Product details
External dimensions mm L x P x A309 x 321 x 209 mm
Control panelDisplay LCD
Unit of measureCarat; Customizable; Wheat; Gram; Hong Kong Tael; Kilogram; Mesghal; Milligram; Momme; Newton; Ounce; Troy ounce; Pennyweight; Pound; Singapore Tael; Taiwan Tael; Tical; Tola
Position size180
SeriesPioneer
Weight kg4,5
SupplyAC adapter (included)
About Jointlab srl

Jointlab.com is a website of professionals for scientific instrumentation. With us you will have answers that others will not give you. From magnetic stirrers to laboratory pumps. From electronic scales to safety cabinets: the whole world of the laboratory in jointlab.com!

About QuestPair

QuestPair is a platform to find and acquire laboratory equipment by connecting research organisations, universities, and companies with high-quality, affordable instruments. The platform facilitates multiple sales daily worldwide and works with partners around the globe to provide trusted, vetted products for a wide variety of scientific needs. Our in-house developed AI algorithms collect data on the usage and availability of scientific instruments, enabling us to provide tailor-made assistance in sourcing suitable laboratory equipment. With a focus on cost-effectiveness and sustainability, QuestPair has an excellent track record in streamlining acquisitions for laboratories to further scientific research and development.

Related items:
Explorer EX224 Ohaus-cover
Explorer EX224 Ohaus

The OHAUS Explorer Analytical Balance Series combines innovative functionality and design elements t (more)o deliver unrivalled functionality in a line of high-performance balances that is unique on the market. These are intelligent and intuitive balances, complemented by a series of innovative features that simplify even the most complex laboratory measurements. Applications Weighing, Parts Counting, Percent Weighing, Checkweighing, Animal/Dynamic Weighing, Filling, Totalization/Statistics, Formulation, Differential Weighing, Density Determination, Peak Hold, Ingredient Costing, Pipette Adjustment, SQC Display 5.7" (145 mm) Full-color VGA graphic touchscreen display with user-controlled brightness Operation AC adapter (included) Communication RS232 and USB (included) or second RS232/Ethernet (accessories sold separately) . GLP/GMP data output with real-time clock. Construction Metal base, ABS top housing, stainless steel pan, glass draftshield with top mounted side doors & flip/sliding top door, illuminated up-front level indicator, weigh below hook, security bracket, calibration lock, 4 touchless sensors, in-use cover Design Features Selectable environmental filters, auto tare, user selectable span calibration points, software lockout and reset menu, user selectable communication settings and data print options, user definable project and user IDs, auto standby, up to 14 operating languages Technical features: Internal Calibration: AutoCal™ - Automatic Screen: Included Lid in use: Included Linearity: ±0.0002g Minimum weight according to (USP, 0.1% typical): 0.16g Repeatability (typical): 0.0001 g Stabilization time: 2 s Tare range: to flow by subtraction

€4,585.00 ex VAT
€5,456.15 incl. VAT if applicable
Italy
weighing terminals, analytical balances accessories
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml-cover
Radwag XA11 - XA Adapter for Pipette Calibration 11 ml

XA11 pipette calibration adapter enables calibration and/or verification of piston pipettes by means (more) of a gravimetric method using the XA microbalance. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 11 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
pipettes calibration, scales, ultra microbalances, ultra & microbalances accessories, analytical balances, analytical balances accessories, balances, balances accessories, microbalances, microbalances accessories, pipettes
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y.A-cover
Radwag XA100 - Adapter for Pipettes calibration 100 ml XA 5Y.A

XA100 pipette calibration adapter enables calibration and/or verification of piston pipettes by mean (more)s of a gravimetric method using the XA analytical balence. Set content: base weighing pan weighing vessel evaporation ring glass chamber with an opening for dosing Evaporation ring is an integral part of the adapter that increases relative humidity inside the weighing chamber. With this evaporation of the liquid during calibration/verification is stopped. An integrated weighing pan enables centric loading of the vessel in the weighing chamber. The weighing pan and the vessel are housed in a glass chamber featuring an opening allowing the user to dispense liquid through it, and reducing air drafts. Vessel capacity: 100 ml Adapters for Pipettes Calibration Pipette calibration adapters are intended for calibration and verification of piston pipettes using gravimetric method. Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel. The table below, which presents the minimum requirements in accordance with ISO 8655-6:2022 standard, enables to select suitable adapter for pipette calibration and respective balance version. The parameters of the balance have been selected so that the expanded uncertainty of measurement in use is less than ¼ of the maximum permissible error of the test object. Nominal volume of apparatus under test V Resolution (d) mg Repeatability (s)3mg Recommended balance Microbalances Analytical balances 0,5 µl ≤ V < 20 µl 0,001c 0,01d 0,006c, e 0,03d MYA 21.5Y XA 6/21.5Y.M.A XA 6/21.5Y.M XA 21.5Y.M.A XA 21.5Y.M XA 21/52.5Y.M.A XA 21/52.5Y.M XA 53.5Y.M.A XA 53.5Y.M 20 µl ≤ V < 200 µl 0,01 0,025 XA 52.5Y XA 110.5Y XA 82/220.5Y.A XA 82/220.5Y XA 120/250.5Y.A XA 120/250.5Y 200 µl ≤ V ≤ 10 ml 0,1 0,2 Adapter for pipette calibration MY 11 XA 11 XA 11 XA 11 XA 11 XA 17 XA 17 XA 17 XA 100 XA 17 XA 100 Maximum vessel capacity 11 ml 11 ml 11 ml 11 ml 11 ml 17 ml 17 ml 17 ml 100 ml 17 ml 100 ml Weighing vessel mass ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 10 g ~ 11 g ~ 11 g ~ 11 g ~ 65 g ~ 11 g ~ 65 g a The repeatability values, in this table, apply in the volumen determination of a single channel pipette. When a single-channel balance is used for volumen determination of single channel pipettes the repeatability values are double the values of this table. c Single-channel balance. d Multichannel balance, only valid for multi-channel pipettes. Multi-channel balances of 0,01 mg readability may be uses to test multi-channel pipettes with nominla volumes below 20 µl only if the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. e For single-channel pipettes of nominal volumes of less than 2 µl, a balance with repeatability better than the values in the table shall be used so that the expanded uncertainty in use is less than ¼ of the maximum permissible systematic error of the test object. table {font-size: 12px} td {padding:10px; } tr {text-align:center;} @media (max-width: 800px) { table {font-size: 9px} td {padding: 1px 1px} }

€1,108.00 ex VAT
Poland
analytical balances, ultra microbalances, analytical balances accessories, ultra & microbalances accessories, scales, pipettes calibration, pipettes, microbalances accessories, microbalances, balances accessories, balances
People are watching right now:
Disclaimer: QuestPair assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided and presented on an “as is“ basis with no guarantees of completeness, accuracy, usefulness or timeliness.

Customer Service

Here to help you with: Product Inquiries, Shipping & Support, Technical Support, Business Inquiries and Press.

We are available to assist you Mon-Fri, 10am - 5pm CET.

+31 (0) 73 7114717
[email protected]